The effect of chart speed on fetal monitor interpretation

被引:5
|
作者
Peleg, David [1 ]
Ram, Reut [1 ]
Warsof, Steven L. [2 ]
Wolf, Maya Frank [1 ]
Larion, Sebastian [2 ]
Beydoun, Hind A. [3 ]
Trochakerian, Sarine [2 ]
Shachar, Inbar Ben [1 ]
机构
[1] Bar Ilan Univ, Ziv Med Ctr, Fac Med, Dept Obstet & Gynecol, Galilee, Israel
[2] Eastern Virginia Med Sch, Div Maternal Fetal Med, Norfolk, VA 23501 USA
[3] Eastern Virginia Med Sch, Grad Program Publ Hlth, Norfolk, VA 23501 USA
来源
关键词
intrapartum fetal assessment; Fetal assessment; fetal heart rate; fetal heart monitor chart speed;
D O I
10.3109/14767058.2015.1054804
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Electronic fetal heart monitor chart speeds vary between countries, and it is unclear whether differing chart speeds affect physician tracing interpretation. Methods: Twenty-minute segments of 19 tracings were displayed on both 1 and 3 cm/min strips and interpreted by 14 physicians at the particular speed they were accustomed to reading. Interpretations of tracing characteristics were compared between groups using free margin kappa, a measure of interobserver agreement. Results: Compared to 3 cm/min tracings, 1 cm/min tracings were significantly more often identified as having absent than minimal variability, and minimal than moderate variability. Accelerations were significantly more often identified in 1 versus 3 cm/min strips. There were no significant differences between groups with respect to baseline fetal heart rate, prolonged or repetitive decelerations, or American College of Obstetricians and Gynecologists tracing category. Neither chart speed had substantial interobserver agreement in tracing variables; however, agreement was consistently higher in 3 versus 1 cm/min tracings (all p < 0.05). Conclusions: Tracing interpretation is significantly affected by fetal monitor chart speed with regards to variability, acceleration and deceleration. Further studies are required to determine if differences in chart speed interpretation affect clinical management.
引用
收藏
页码:1577 / 1580
页数:4
相关论文
共 50 条
  • [31] SPEED/POWER CHART FOR DIGITAL ICS
    不详
    [J]. ELECTRONIC ENGINEER, 1970, 29 (06): : 58 - &
  • [32] 1424-CHART AND ITS FANTASTIC INTERPRETATION
    KOGAN, MA
    [J]. SOVIET GEOGRAPHY REVIEW AND TRANSLATION, 1979, 20 (08): : 504 - 510
  • [33] Reference chart of inspiratory muscle strength: a new tool to monitor the effect of pre-operative training
    van Buuren, S.
    Hulzebos, E. H. J.
    Valkenet, K.
    Lindeman, E.
    van Meeteren, N. L. U.
    [J]. PHYSIOTHERAPY, 2014, 100 (02) : 128 - 133
  • [34] Does the paper speed in fetal heart monitoring during labour influence the variability in the interpretation by professionals?
    Lemoine, H.
    Ehlinger, V.
    Groussolles, M.
    Arnaud, C.
    Vayssiere, C.
    [J]. JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2016, 45 (08): : 827 - 834
  • [35] The Fetal Heart Monitor Tracing in Pregnancies Complicated by Fetal Thyrotoxicosis
    Towers, Craig V.
    Thomas, Steven
    Steiger, Ralph M.
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2009, 26 (05) : 373 - 377
  • [36] A new control chart to monitor the mean vector of a trivariate process
    Gadre, Mukund P.
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2023, 39 (06) : 2113 - 2124
  • [37] A single CUSUM chart using a single observation to monitor a variable
    Wu, Zhang
    Wang, Qinan
    [J]. INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2007, 45 (03) : 719 - 741
  • [38] A transformation-based multivariate chart to monitor process dispersion
    B. Abbasi
    S. T. A. Niaki
    M. Abdollahian
    S. Z. Hosseinifard
    [J]. The International Journal of Advanced Manufacturing Technology, 2009, 44 : 748 - 756
  • [40] A NEW CHART TO MONITOR WEIGHT-GAIN DURING PREGNANCY