The effect of chart speed on fetal monitor interpretation

被引:5
|
作者
Peleg, David [1 ]
Ram, Reut [1 ]
Warsof, Steven L. [2 ]
Wolf, Maya Frank [1 ]
Larion, Sebastian [2 ]
Beydoun, Hind A. [3 ]
Trochakerian, Sarine [2 ]
Shachar, Inbar Ben [1 ]
机构
[1] Bar Ilan Univ, Ziv Med Ctr, Fac Med, Dept Obstet & Gynecol, Galilee, Israel
[2] Eastern Virginia Med Sch, Div Maternal Fetal Med, Norfolk, VA 23501 USA
[3] Eastern Virginia Med Sch, Grad Program Publ Hlth, Norfolk, VA 23501 USA
来源
关键词
intrapartum fetal assessment; Fetal assessment; fetal heart rate; fetal heart monitor chart speed;
D O I
10.3109/14767058.2015.1054804
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Electronic fetal heart monitor chart speeds vary between countries, and it is unclear whether differing chart speeds affect physician tracing interpretation. Methods: Twenty-minute segments of 19 tracings were displayed on both 1 and 3 cm/min strips and interpreted by 14 physicians at the particular speed they were accustomed to reading. Interpretations of tracing characteristics were compared between groups using free margin kappa, a measure of interobserver agreement. Results: Compared to 3 cm/min tracings, 1 cm/min tracings were significantly more often identified as having absent than minimal variability, and minimal than moderate variability. Accelerations were significantly more often identified in 1 versus 3 cm/min strips. There were no significant differences between groups with respect to baseline fetal heart rate, prolonged or repetitive decelerations, or American College of Obstetricians and Gynecologists tracing category. Neither chart speed had substantial interobserver agreement in tracing variables; however, agreement was consistently higher in 3 versus 1 cm/min tracings (all p < 0.05). Conclusions: Tracing interpretation is significantly affected by fetal monitor chart speed with regards to variability, acceleration and deceleration. Further studies are required to determine if differences in chart speed interpretation affect clinical management.
引用
收藏
页码:1577 / 1580
页数:4
相关论文
共 50 条
  • [1] FACTORS INVOLVED IN THE INTERPRETATION OF FETAL MONITOR TRACINGS
    HELFAND, M
    MARTON, K
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 151 (06) : 737 - 744
  • [2] Improving obstetricians' accordance in fetal monitor interpretation during childbirth
    Shapira, Rotem
    Kedar, Reuven
    Damti, Amit
    Yaniv, Yael
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2023, 130 : 94 - 94
  • [3] Improving obstetricians' accordance in fetal monitor interpretation during childbirth
    Shapira, Rotem
    Kedar, Reuven
    Damti, Amit
    Yaniv, Yael
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2023, 130 : 94 - 94
  • [4] FM TUTOR - COMPUTER-AIDED-INSTRUCTION FOR FETAL MONITOR INTERPRETATION
    NARRIGAN, D
    [J]. JOURNAL OF NURSE-MIDWIFERY, 1987, 32 (06): : 374 - 375
  • [5] The Effect of Music Intervention on Fetal Education via Doppler Fetal Monitor
    Lee, Liza
    Chang, Yu-Hsin
    Liang, Wei-Ju
    Huang, Yao-Cing
    [J]. CHILDREN-BASEL, 2022, 9 (06):
  • [6] INTERPRETATION OF CHART RECORDINGS
    JUDKINS, JR
    [J]. INSTRUMENTS & CONTROL SYSTEMS, 1976, 49 (01): : 51 - 54
  • [7] Effect of new electronic chart on fetal growth surveillance and management
    Butler, Emily
    Ellson, Hanna
    Hugh, Oliver
    Gardosi, Jason
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2023, 130 : 187 - 187
  • [8] A mixed control chart to monitor the process
    Aslam, Muhammad
    Azam, Muhammad
    Khan, Nasrullah
    Jun, Chi-Hyuck
    [J]. INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2015, 53 (15) : 4684 - 4693
  • [9] Examination and Optimization of the Fetal Heart Rate Monitor Evaluation of the effect influencing the measuring system of the Fetal Heart Rate Monitor
    Kolarik, Jakub
    Soustek, Lukas
    Martinek, Radek
    [J]. 2018 IEEE 20TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM), 2018,
  • [10] Control chart to monitor circular data
    Lima-Filho, Luiz M. A.
    Bayer, Fabio M.
    da Silva, Augusto M.
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2021, 37 (03) : 966 - 983