Infraposition of anterior maxillary implant-supported single-tooth restorations in adolescent and adult patients-A prospective follow-up study up to 6 years

被引:6
|
作者
Nilsson, Andree [1 ,2 ]
Johansson, Lars-Ake [1 ,3 ]
Stenport, Victoria F. [2 ]
Wennerberg, Ann [2 ]
Ekfeldt, Anders [4 ]
机构
[1] Halmstad Cty Hosp, Maxillofacial Unit, Div Prosthet Dent, Halmstad, Sweden
[2] Gothenburg Univ, Sahlgrenska Acad, Inst Odontol, Dept Prosthodontics Dent Mat Sci, Gothenburg, Sweden
[3] Malmo Univ, Fac Odontol, Dept Periodontol, Carl Gustavs Vag 34, SE-20506 Malmo, Sweden
[4] Univ Oslo, Inst Clin Dent, Fac Dent, Dept Prosthet Dent & Oral Funct, Oslo, Norway
关键词
clinical study; complications; dental implants; implant supported crown; infraposition; maxilla; patient satisfaction; ZIRCONIA ABUTMENTS; INCISOR REGION; ADJACENT TEETH; PLACEMENT; GROWTH; CROWNS; PINK;
D O I
10.1111/cid.12818
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background In the maxillary incisor area infraposition of implant restorations can be an esthetic problem. Purpose The aim was to analyze the prevalence of infraposition of single-tooth implant restorations in the anterior maxilla in adolescent and adult patients. Material and Methods The study comprised of 31 patients, 18 women and 13 men, with 39 restorations and with a mean and median age of 23.8 and 18.8 years, range 17.8 to 52.8 years, at the time of implant crown connection. The mean and median time in function for the restorations was 4.5 and 4.3 years respectively with a range of 3.3 to 6.6 years. Results Twenty restorations 51%, showed no signs of infraposition. A slight infraposition (<0.5 mm) was seen in 36% of the restorations. Only in one patient, the observed infraposition of the implant crown was more than 1 mm. We found no significant difference of the observed level of vertical infraposition, Score A (0 mm) and Score B (<0.5 mm), in subjects where the restoration was placed before the age of 20 years compared to the older patients. There were no significant differences in changes of the vertical infraposition when comparing different parameters such as age, gender, jaw relation (Angle-classes I-III), overbite/overjet, occlusal contact on the implant crown, bone augmentation before or at implant installation or if orthodontic treatment of the neighboring teeth had been made before or after the implant installation. Conclusions In the present study, there was a significant yet low correlation between the observed vertical infraposition of the single-tooth implant restoration and the subject's evaluation of the esthetics of the restoration (VAS). Fifty-one percent of the implant-supported crowns, showed no signs of vertical infraposition. A slight infraposition (< 0.5 mm) was however seen in 36% of the restorations. Only one crown showed a vertical infraposition of more than 1 mm.
引用
收藏
页码:953 / 959
页数:7
相关论文
共 50 条
  • [41] Full-zirconia single-tooth molar implant-supported restorations with angulated screw channel abutments: A 1-year prospective case series study
    Pol, Christiaan W. P.
    Raghoebar, Gerry M.
    Maragkou, Zakelina
    Cune, Marco S.
    Meijer, Henny J. A.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (01) : 138 - 144
  • [42] Implant-supported crowns on maxillary laterals and canines-a long-term follow-up of aesthetics and function
    Sanatnama, Elnaz
    Frantz, Lena
    Ahlin, Erik
    Naoumova, Julia
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (12) : 7545 - 7555
  • [43] Dental implants as strategic supplementary abutments for implant-tooth-supported telescopic crown-retained maxillary dentures:: A retrospective follow-up study for up to 9 years
    Krennmair, Gerald
    Krainhoefner, Martin
    Waldenberger, Otmar
    Pielhslinger, Eva
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2007, 20 (06) : 617 - 622
  • [44] Survival and Mechanical Complications of Posterior Single Implant-Supported Restorations Using Prefabricated Titanium Abutments: A Medium- and Long-Term Retrospective Analysis with up to 10 Years Follow-up
    Di Francesco, Fabrizio
    De Marco, Gennaro
    Cristache, Corina M.
    Vernal, Rolando
    Cafferata, Emilio A.
    Lanza, Alessandro
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (03) : 278 - 286
  • [45] Long-Term Follow-Up of CeraOne™ Single-Implant Restorations: An 18-Year Follow-Up Study Based on a Prospective Patient Cohort
    Bergenblock, Sibel
    Andersson, Bernt
    Furst, Bjorn
    Jemt, Torsten
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (04) : 471 - 479
  • [46] Changes of anterior clinical crown height in patients provided with single-implant restorations after more than 15 years of follow-up
    Jemt, Torsten
    Ahlberg, Gunilla
    Henriksson, Kristina
    Bondevik, Olav
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2006, 19 (05) : 455 - 461
  • [47] One-piece internal zirconia abutments for single-tooth restorations on narrow and regular diameter implants: A 5-year prospective follow-up study
    Nilsson, Andree
    Johansson, Lars-Ake
    Lindh, Christina
    Ekfeldt, Anders
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 916 - 925
  • [48] Survival Rate of Implants and Mechanical Complications for 64 Implant-Supported Complete-Arch Prostheses in Maxillary Edentulous Patients with a Follow-up of up to 12 Years: A Cross-Sectional Analytical Study
    Younes, Ibrahim Abazar
    Able, Francine Badin
    De Moraes, Kely Cristina
    Sartori, Ivete Aparecida de Mattias
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : 823 - 828
  • [49] Use of separate single-tooth implant restorations to replace two or more consecutive posterior teeth: a prospective cohort study for up to 1 year
    Kwon, Min-Jung
    Yeo, In-Sung
    Kim, Young-Kyun
    Yi, Yang-Jin
    Yang, Jae-Ho
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (02): : 54 - 57
  • [50] Interproximal contact loss between implant-supported restorations and adjacent natural teeth: A retrospective cross-sectional study of 83 restorations with an up to 10-year follow-up
    Bompolaki, Despoina
    Edmondson, Sara A.
    Katancik, James A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 418 - 424