Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry

被引:50
|
作者
Grant, RP [1 ]
Cameron, C [1 ]
Mackenzie-McMurter, S [1 ]
机构
[1] Eli Lily Canada Inc, Lilly Lab Bioanalyt Res, Toronto, ON M1N 2E8, Canada
关键词
D O I
10.1002/rcm.784
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of turbulent flow chromatography (TFC) has enabled considerable growth in the utility of on-line direct-injection technologies. TFC has now become established in a large number of varied analytical environments, particularly drug discovery/pharmacokinetics, metabolite profiling, combinatorial library purification, pre-clinical and clinical GLP applications. The utility of turbulent flow technology for in-house pre-clinical and clinical quantitative applications has necessitated extensive valve-cleaning procedures, and consequently lengthy cycle-times, to effectively remove the system carry-over. In-house requirements for assay validation require carry-over less than 20% of the lowest level of quantification (LLOQ), corresponding to 0.02% carry-over for a linear calibration range incorporating 3 orders. A generic turbulent flow chromatography protocol has been developed for drug discovery that incorporates polymeric turbulent flow extraction (cyclone) with C18-based reverse-phase chromatography. Further, multiple wash steps are incorporated within the methodology to meet in-house requirements for carry-over. Selection of novel switching-valve materials based on polyarylethyl ketone (PAEK) and Hastelloy/Valcon E autosampler injection hardware has enabled us to significantly impact the cycle-time required to reduce carry-over. Consequently, optimal usage of switching valves has enabled parallel operation for a generic on-line direct-injection methodology to successfully reduce the total cycle-time. Overall reductions from 4 min per sample to 90 s per sample are shown with comparable data quality using a proprietary target molecule from 0.1-100 ng/mL. This paper describes the hardware configuration and methodologies utilized to perform generic serial and parallel on-line direct-injection using a Turboflow HTLC 2300 system. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1785 / 1792
页数:8
相关论文
共 50 条
  • [31] Quantification of sirolimus by liquid chromatography-tandem mass spectrometry using on-line solid-phase extraction
    Vogeser, M
    Fleischer, C
    Meiser, B
    Groetzner, J
    Spöhrer, U
    Seidel, D
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (01) : 40 - 45
  • [32] Identification and Characterization of Polyphenolic Antioxidants Using On-Line Liquid Chromatography, Electrochemistry, and Electrospray Ionization Tandem Mass Spectrometry
    Zettersten, Camilla
    Co, Michelle
    Wende, Sandra
    Turner, Charlotta
    Nyholm, Leif
    Sjoberg, Per J. R.
    ANALYTICAL CHEMISTRY, 2009, 81 (21) : 8968 - 8977
  • [33] On-line turbulent-flow chromatography-high-performance liquid chromatography-mass spectrometry for fast sample preparation and quantitation
    Ynddal, L
    Hansen, SH
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) : 59 - 67
  • [34] Determination of six progesterones in milk by on-line cleanup liquid chromatography-tandem mass spectrometry
    Duan Yongsheng
    Wang Bingling
    Ai Lianfeng
    Guo Chunhai
    Ge Shihui
    Zhang Jingwen
    Xu Niusheng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (06) : 647 - 652
  • [35] On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry
    Lee, Ju Yong
    Yang, Joon Seon
    Park, Se Mi
    Byeon, Seul Kee
    Moon, Myeong Hee
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1464 : 12 - 20
  • [36] Microdialysis coupled on-line to capillary liquid chromatography with tandem mass spectrometry for monitoring acetylcholine in vivo
    Shackman, Holly M.
    Shou, Minshan
    Cellar, Nicholas A.
    Watson, Christopher J.
    Kennedy, Robert T.
    JOURNAL OF NEUROSCIENCE METHODS, 2007, 159 (01) : 86 - 92
  • [37] Characterization of therapeutic oligonucleotides using liquid chromatography with on-line mass spectrometry detection
    Gilar, M
    Fountain, KJ
    Budman, Y
    Holyoke, JL
    Davoudi, H
    Gebler, JC
    OLIGONUCLEOTIDES, 2003, 13 (04) : 229 - 243
  • [38] Simulation of the detoxification of paracetamol using on-line electrochemistry/liquid chromatography/mass spectrometry
    Wiebke Lohmann
    Uwe Karst
    Analytical and Bioanalytical Chemistry, 2006, 386 : 1701 - 1708
  • [39] Simulation of the detoxification of paracetamol using on-line electrochemistry/liquid chromatography/mass spectrometry
    Lohmann, Wiebke
    Karst, Uwe
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (06) : 1701 - 1708
  • [40] A rapid and reliable method for the quantitation of hydroxychloroquine in serum using turbulent flow liquid chromatography-tandem mass spectrometry
    Fuezery, Anna K.
    Breaud, Autumn R.
    Emezienna, Nkechinyere
    Schools, Sabitha
    Clarke, William A.
    CLINICA CHIMICA ACTA, 2013, 421 : 79 - 84