Development of a New Type of Manganese Bath for determination of Neutron Emission Rate of a Neutron Source

被引:0
|
作者
Matsumoto, Tetsuro [1 ]
Harano, Hideki [1 ]
Masuda, Akiniko [1 ]
Hori, Jun-ichi [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Cent 2, 1-1-1 Umezono, Tsukuba, Ibaraki 3058568, Japan
[2] Kyoto Univ, Inst Res Reactor, Kumatori, Osaka 5900494, Japan
基金
日本学术振兴会;
关键词
CALIBRATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We are developing a new type of manganese bath for determination of neutron emission rate of a radioactive neutron source. The manganese bath gas a multilayered structure composed of polyethylene plates and manganese alloy plates containing 70 A, manganese. In measurements of neutron emission rate, a neutron source is set in the center of the manganese bath at first. Mn-55 is produced by the Mn-55(n,gamma)Mn-56 reaction. The neutron emission rate is finally determined by measuring gamma rays emitted from Mn-56 using a NaI(TI) scintillation detector with a 5.08 cm diameter and a 5.08 cm length and a high purity Ge detector with relative efficiency of 60%.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] DETERMINATION OF MANGANESE IN PYROLUSITES BY NEUTRON-ACTIVATION ANALYSIS USING LOW FLUX 241AM-BE NEUTRON SOURCE
    BATRA, RJ
    GARG, AN
    JOURNAL OF THE GEOLOGICAL SOCIETY OF INDIA, 1986, 28 (04) : 315 - 319
  • [32] Determination of 4.438 MeV γ-ray to neutron emission ratio from a 241Am-9Be neutron source
    Mowlavi, AA
    Koohi-Fayegh, R
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (06) : 959 - 962
  • [33] MIRROR TYPE NEUTRON SOURCE
    RYUTOV, DD
    PLASMA PHYSICS AND CONTROLLED FUSION, 1990, 32 (11) : 999 - 1009
  • [34] Experimental Measurement of the Neutron Emission Rate
    Osusky, Filip
    Vrban, Branislav
    Luley, Jakub
    Cerba, Stefan
    Hascik, Jan
    26TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2017), 2017,
  • [35] Convenient method of relative calibration of the neutron source emission rate between different source types
    Harano, H
    Matsumoto, T
    Shimoyama, T
    Sato, Y
    Uritani, A
    Hino, Y
    Kudo, K
    Michikawa, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1413 - 1417
  • [36] Convenient method of relative calibration of the neutron source emission rate between different source types
    Harano, H.
    Matsumoto, T.
    Shimoyama, T.
    Sato, Y.
    Uritani, A.
    Hino, Y.
    Kudo, K.
    Michikawa, T.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 524 - 528
  • [37] DETERMINATION OF MANGANESE IN BONE BY NEUTRON ACTIVATION ANALYSIS
    ROJAS, MA
    DYER, IA
    CASSATT, WA
    ANALYTICAL CHEMISTRY, 1966, 38 (06) : 788 - &
  • [38] DETERMINATION OF MANGANESE IN TISSUES BY NEUTRON ACTIVATION ANALYSIS
    HAHN, KJ
    HAVEN, MC
    TUMA, DJ
    OGBORN, RE
    QUAIFE, MA
    NUCLEAR APPLICATIONS, 1967, 3 (05): : 314 - &
  • [39] DETERMINATION OF MANGANESE IN TISUES BY NEUTRON ACTIVATION ANALYSIS
    HAHN, KJ
    HAVEN, MC
    TUMA, DJ
    OGBORN, RE
    QUAIFE, MA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1966, 9 (01): : 71 - &
  • [40] NEUTRON ACTIVATION DETERMINATION OF MANGANESE IN BODY FLUIDS
    PAPAVASILIOU, PS
    COTZIAS, GC
    FEDERATION PROCEEDINGS, 1960, 19 (01) : 250 - 250