Development of a New Type of Manganese Bath for determination of Neutron Emission Rate of a Neutron Source

被引:0
|
作者
Matsumoto, Tetsuro [1 ]
Harano, Hideki [1 ]
Masuda, Akiniko [1 ]
Hori, Jun-ichi [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Cent 2, 1-1-1 Umezono, Tsukuba, Ibaraki 3058568, Japan
[2] Kyoto Univ, Inst Res Reactor, Kumatori, Osaka 5900494, Japan
基金
日本学术振兴会;
关键词
CALIBRATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We are developing a new type of manganese bath for determination of neutron emission rate of a radioactive neutron source. The manganese bath gas a multilayered structure composed of polyethylene plates and manganese alloy plates containing 70 A, manganese. In measurements of neutron emission rate, a neutron source is set in the center of the manganese bath at first. Mn-55 is produced by the Mn-55(n,gamma)Mn-56 reaction. The neutron emission rate is finally determined by measuring gamma rays emitted from Mn-56 using a NaI(TI) scintillation detector with a 5.08 cm diameter and a 5.08 cm length and a high purity Ge detector with relative efficiency of 60%.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Neutron-emission Measurements at a White Neutron Source
    Haight, R. C.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 1553 - 1557
  • [23] IMPROVEMENTS IN MANGANESE BATH TECHNIQUE FOR CALIBRATION OF NEUTRON SOURCES
    AXTON, EJ
    ROBERTSON, JC
    CROSS, P
    JOURNAL OF NUCLEAR ENERGY PARTS A AND B-REACTOR SCIENCE AND TECHNOLOGY, 1963, 17 (10): : 440 - &
  • [24] EXTENSION OF RANGE OF DETERMINATION OF MANGANESE SULPHATE CONTENT FOR NEUTRON SOURCE MEASUREMENTS
    DEVOLPI, A
    ARMANI, RJ
    PORGES, KG
    JOURNAL OF NUCLEAR ENERGY, 1967, 21 (06): : 521 - &
  • [25] In-vessel calibration of JET neutron detectors: Comparison of methods of neutron emission rate determination
    Laszynska, E.
    Batistoni, P.
    Cufar, A.
    Ghani, Z.
    Jednorog, S.
    Packer, L. W.
    Popovichev, S.
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 1661 - 1664
  • [26] Cathode cooling effects on the neutron production rate in the glow discharge type of fusion neutron source
    Sakabe, Toshiro
    Ishii, Takaya
    Mukai, Keisuke
    Yagi, Juro
    JOURNAL OF APPLIED PHYSICS, 2024, 136 (04)
  • [27] Figaro: Measuring neutron emission spectra with a white neutron source
    Haight, RC
    O'Donnell, JM
    Zanini, L
    Devlin, M
    Rochman, D
    CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2003, : 451 - 459
  • [28] NEUTRON ACTIVATION ANALYSIS - DETERMINATION OF MANGANESE
    PAPAVASILIOU, P
    COTZIAS, GC
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1961, 236 (08) : 2365 - &
  • [29] DETERMINATION OF MANGANESE IN ALUMINUM BY NEUTRON-ACTIVATION WITH A CF-252 SOURCE
    SAILER, K
    DAROTSI, S
    NAD, S
    RAICH, P
    CHIKAI, I
    GERGEI, L
    SOVIET ATOMIC ENERGY, 1975, 39 (04): : 911 - 912
  • [30] IRRADIATOR SYSTEM FOR MANGANESE SULFATE BATH EFFICIENCY MEASUREMENTS USING A PLUTONIUM-BERYLLIUM NEUTRON SOURCE
    Silva, F. S.
    Martins, M. M.
    Conti, C. C.
    Leite, S. P.
    Fonseca, E. S.
    Patrao, K. C. S.
    Pereira, W. W.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 42 - 45