Research on the Uncertainty Propagation of the Removal Algorithm of Time-base Errors

被引:0
|
作者
Zhao Linxiao [1 ]
Zhu Jiangmiao [1 ]
Miao Jingyuan [2 ]
Zhang Yueqian [1 ]
机构
[1] Beijing Univ Technol, Coll Elect Informat & Control Engn, Beijing 100124, Peoples R China
[2] Natl Inst Metrol, Beijing 100013, Peoples R China
关键词
Uncertainty propagation; time-base drift; time-base jitter; time -base distortion;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Time-base drift, time-base jitter and time -base distortion are the important factors affect the accuracy of the calibration of the broadband oscilloscope. Therefore, the removal algorithms should be designed to remove or correct the time-base errors. On the study of uncertainty propagation, the results after the propagation algorithms of removing the time -base errors should be considered. Therefore, the uncertainty propagation should be considered to make the uncertainty of bandwidth of oscilloscope more reasonable. This paper introduced the methods to remove time-base errors, and studied the uncertainty propagation of removing the time-base errors. Finally, the experiment data were processed to verify that the results of uncertainty evaluation are more reasonable by considering the uncertainty propagation of the time -base errors removal algorithms.
引用
收藏
页码:257 / 261
页数:5
相关论文
共 50 条
  • [31] SOLID-STATE SEQUENCER FOR TIME-BASE CONTROL
    不详
    DESIGN NEWS, 1978, 34 (22) : 85 - &
  • [33] Hybrid Time-Base Device for Coherent Sampling Oscilloscope
    Tankeliun, Tomas
    Zaytsev, Oleg
    Urbanavicius, Vytautas
    MEASUREMENT SCIENCE REVIEW, 2019, 19 (03): : 93 - 100
  • [34] APPLICATION OF EXPONENTIAL TIME-BASE IN RECORDING OF EVOKED RESPONSES IN MAN
    CIGANEK, L
    ZALCIK, J
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1965, 18 (02): : 190 - &
  • [35] CORRELATION OF ACOUSTIC WAVEFRONT AND SIGNAL TIME-BASE INSTABILITIES IN OCEAN
    WILLIAMS, RE
    WEI, CH
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 59 (06): : 1310 - 1316
  • [36] A time-base sweep unit for the PA-2 polarograph
    Ovchinnikov A.V.
    Gabdullin M.G.
    Biomedical Engineering, 1998, 32 (4) : 242 - 243
  • [37] SPECTRAL MODEL FOR TIME-BASE DISTORTIONS IN MAGNETIC RECORDING.
    Totzek, Ulrich
    Preis, Douglas
    Bohme, Johann F.
    AEU. Archiv fur Elektronik und Ubertragungstechnik, 1987, 41 (04): : 223 - 231
  • [38] DIGITAL TIME-BASE CORRECTION FOR VIDEO SIGNAL-PROCESSING
    ACKER, DE
    MCLEAN, RH
    SMPTE JOURNAL, 1976, 85 (03): : 146 - 150
  • [39] A DIGITAL AUDIO TIME-BASE CORRECTOR FOR LINEAR MAGNETIC RECORDING
    ROSBACK, TJ
    SMPTE JOURNAL, 1985, 94 (04): : 481 - 481
  • [40] A DIGITAL AUDIO TIME-BASE CORRECTOR FOR LINEAR MAGNETIC RECORDING
    ROSBACK, TJ
    SMPTE JOURNAL, 1985, 94 (11): : 1180 - 1184