Quantitation of five organophosphorus nerve agent metabolites in serum using hydrophilic interaction liquid chromatography and tandem mass spectrometry

被引:42
|
作者
Hamelin, Elizabeth I. [1 ]
Schulze, Nicholas D. [2 ]
Shaner, Rebecca L. [1 ]
Coleman, Rebecca M. [2 ]
Lawrence, Richard J. [3 ]
Crow, Brian S. [1 ]
Jakubowski, E. M. [3 ]
Johnson, Rudolph C. [1 ]
机构
[1] Ctr Dis Control & Prevent, Div Sci Lab, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
[2] ORISE, Oak Ridge, TN 37831 USA
[3] US Army Edgewood Chem Biol Ctr, R&T Directorate, Aberdeen, MD 21010 USA
关键词
Organophosphorus nerve agents; Metabolites; Serum; Exposure; ISOPROPYL METHYLPHOSPHONIC ACID; ISOTOPE-DILUTION; HUMAN URINE; DEGRADATION-PRODUCTS; QUANTIFICATION; SAMPLES; SARIN; SOMAN; IONIZATION; EXTRACTION;
D O I
10.1007/s00216-014-7702-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although nerve agent use is prohibited, concerns remain for human exposure to nerve agents during decommissioning, research, and warfare. Exposure can be detected through the analysis of hydrolysis products in urine as well as blood. An analytical method to detect exposure to five nerve agents, including VX, VR (Russian VX), GB (sarin), GD (soman), and GF (cyclosarin), through the analysis of the hydrolysis products, which are the primary metabolites, in serum has been developed and characterized. This method uses solid-phase extraction coupled with high-performance liquid chromatography for separation and isotopic dilution tandem mass spectrometry for detection. An uncommon buffer of ammonium fluoride was used to enhance ionization and improve sensitivity when coupled with hydrophilic interaction liquid chromatography resulting in detection limits from 0.3 to 0.5 ng/mL. The assessment of two quality control samples demonstrated high accuracy (101-105 %) and high precision (5-8 %) for the detection of these five nerve agent hydrolysis products in serum.
引用
收藏
页码:5195 / 5202
页数:8
相关论文
共 50 条
  • [41] Detection and quantitation of ecdysterone in human serum by liquid chromatography coupled to tandem mass spectrometry
    Ambrosio, Gabriella
    Joseph, Jan Felix
    Wuest, Bernhard
    Mazzarino, Monica
    de la Torre, Xavier
    Diel, Patrick
    Botre, Francesco
    Parr, Maria Kristina
    STEROIDS, 2020, 157
  • [42] Determination of tiapride in human plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Moon, Y
    Paek, IB
    Kim, HH
    Ji, HY
    Lee, HW
    Park, HG
    Lee, HS
    ARCHIVES OF PHARMACAL RESEARCH, 2004, 27 (09) : 901 - 905
  • [43] Hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry method for quantification of five phospholipid classes in various matrices
    Mazzella, Nicolas
    Moreira, Aurelie
    Eon, Melissa
    Medina, Arthur
    Millan-Navarro, Debora
    Creusot, Nicolas
    METHODSX, 2023, 10
  • [44] DETERMINATION OF URINARY CREATINE AND GUANIDINOACETATE BY HYDROPHILIC INTERACTION LIQUID CHROMATOGRAPHY AND TANDEM MASS SPECTROMETRY
    Kok, F.
    Madeira, M. F.
    Cardozo, K. H.
    Carvalho, V. M.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2011, 34 : S128 - S128
  • [45] Hydrophilic Interaction Liquid Chromatography Tandem Mass Spectrometry Method for the Determination of Bicozamycin in Milk
    Inoue, Koichi
    Yamada, Erina
    Hino, Tomoaki
    Oka, Hisao
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (13) : 1914 - 1924
  • [46] Hydrophilic interaction liquid chromatography/tandem mass spectrometry for the analysis of diallyldimethylammonium chloride in water
    Esparza, X.
    Moyano, E.
    Ventura, F.
    Galceran, M. T.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (02) : 379 - 387
  • [47] Hydrophilic interaction liquid chromatography-tandem mass spectrometry for quantitation of paralytic shellfish toxins: validation and application to reference materials
    Thomas, Krista M.
    Beach, Daniel G.
    Reeves, Kelley L.
    Gibbs, Ryan S.
    Kerrin, Elliott S.
    McCarron, Pearse
    Quilliam, Michael A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (24) : 5675 - 5687
  • [48] Hydrophilic interaction liquid chromatography-tandem mass spectrometry for quantitation of paralytic shellfish toxins: validation and application to reference materials
    Krista M. Thomas
    Daniel G. Beach
    Kelley L. Reeves
    Ryan S. Gibbs
    Elliott S. Kerrin
    Pearse McCarron
    Michael A. Quilliam
    Analytical and Bioanalytical Chemistry, 2017, 409 : 5675 - 5687
  • [49] Analysis of plant nucleotide sugars by hydrophilic interaction liquid chromatography and tandem mass spectrometry
    Ito, Jun
    Herter, Thomas
    Baidoo, Edward E. K.
    Lao, Jeemeng
    Vega-Sanchez, Miguel E.
    Smith-Moritz, A. Michelle
    Adams, Paul D.
    Keasling, Jay D.
    Usadel, Bjoern
    Petzold, Christopher J.
    Heazlewood, Joshua L.
    ANALYTICAL BIOCHEMISTRY, 2014, 448 : 14 - 22
  • [50] Analysis of drugs of abuse in wastewater by hydrophilic interaction liquid chromatography–tandem mass spectrometry
    Alexander L. N. van Nuijs
    Isabela Tarcomnicu
    Lieven Bervoets
    Ronny Blust
    Philippe G. Jorens
    Hugo Neels
    Adrian Covaci
    Analytical and Bioanalytical Chemistry, 2009, 395 : 819 - 828