摘要
In orthopaedic surgery, resection of pelvic bone tumors can be inaccurate due to complex geometry, limited visibility and restricted working space of the pelvis. The present study investigated accuracy of patient-specific instrumentation (PSI) for bone-cutting during simulated tumor surgery within the pelvis. A synthetic pelvic bone model was imaged using a CT-scanner. The set of images was reconstructed in 3D and resection of a simulated periacetabular tumor was defined with four target planes (ischium, pubis, anterior ilium, and posterior ilium) with a 10-mm desired safe margin. Patient-specific instruments for bone-cutting were designed and manufactured using rapid-prototyping technology. Twenty-four surgeons (10 senior and 14 junior) were asked to perform tumor resection. After cutting, ISO1101 location and flatness parameters, achieved surgical margins and the time were measured. With PSI, the location accuracy of the cut planes with respect to the target planes averaged 1 and 1.2 mm in the anterior and posterior ilium, 2 mm in the pubis and 3.7 mm in the ischium (p < 0.0001). Results in terms of the location of the cut planes and the achieved surgical margins did not reveal any significant difference between senior and junior surgeons (p = 0.2214 and 0.8449, respectively). The maximum differences between the achieved margins and the 10-mm desired safe margin were found in the pubis (3.1 and 5.1 mm for senior and junior surgeons respectively). Of the 24 simulated resection, there was no intralesional tumor cutting. This study demonstrates that using PSI technology during simulated bone cuts of the pelvis can provide good cutting accuracy. Compared to a previous report on computer assistance for pelvic bone cutting, PSI technology clearly demonstrates an equivalent value-added for bone cutting accuracy than navigation technology. When in vivo validated, PSI technology may improve pelvic bone tumor surgery by providing clinically acceptable margins.
引用
收藏
页码:205 / 213
页数:9
相关论文
共 50 条
  • [1] Improved Accuracy with 3D Planning and Patient-Specific Instruments During Simulated Pelvic Bone Tumor Surgery
    Olivier Cartiaux
    Laurent Paul
    Bernard G. Francq
    Xavier Banse
    Pierre-Louis Docquier
    Annals of Biomedical Engineering, 2014, 42 : 205 - 213
  • [2] 3D osteotomies—improved accuracy with patient-specific instruments (PSI)
    Maximilian Jörgens
    Alexander M. Keppler
    Philipp Ahrens
    Wolf Christian Prall
    Marcel Bergstraesser
    Andreas T. Bachmeier
    Christian Zeckey
    Adrian Cavalcanti Kußmaul
    Wolfgang Böcker
    Julian Fürmetz
    European Journal of Trauma and Emergency Surgery, 2024, 50 : 3 - 10
  • [3] 3D osteotomies-improved accuracy with patient-specific instruments (PSI)
    Joergens, Maximilian
    Keppler, Alexander M.
    Ahrens, Philipp
    Prall, Wolf Christian
    Bergstraesser, Marcel
    Bachmeier, Andreas T.
    Zeckey, Christian
    Kussmaul, Adrian Cavalcanti
    Boecker, Wolfgang
    Fuermetz, Julian
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024, 50 (01) : 3 - 10
  • [4] How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study
    Sallent, A.
    Vicente, M.
    Reverte, M. M.
    Lopez, A.
    Rodriguez-Baeza, A.
    Perez-Dominguez, M.
    Velez, R.
    BONE & JOINT RESEARCH, 2017, 6 (10): : 577 - 583
  • [5] Fluoroscopically calibrated 3D-printed patient-specific instruments improve the accuracy of osteotomy during bone tumor resection adjacent to joints
    Wang, Chen
    Huang, Siyi
    Yu, Yue
    Liang, Haijie
    Wang, Ruifeng
    Tang, Xiaodong
    Ji, Tao
    3D PRINTING IN MEDICINE, 2024, 10 (01)
  • [6] Multidisciplinary Assessment of Planning and Resection of Complex Bone Tumor Using Patient-Specific 3D Model
    Anil Murat Ozturk
    Suzan Sirinturk
    Levent Kucuk
    Fulya Yaprak
    Figen Govsa
    Mehmet Asim Ozer
    Ufuk Cagirici
    Dundar Sabah
    Indian Journal of Surgical Oncology, 2019, 10 : 115 - 124
  • [7] Multidisciplinary Assessment of Planning and Resection of Complex Bone Tumor Using Patient-Specific 3D Model
    Ozturk, Anil Murat
    Sirinturk, Suzan
    Kucuk, Levent
    Yaprak, Fulya
    Govsa, Figen
    Ozer, Mehmet Asim
    Cagirici, Ufuk
    Sabah, Dundar
    INDIAN JOURNAL OF SURGICAL ONCOLOGY, 2019, 10 (01) : 115 - 124
  • [8] 3D planning and surgical navigation of clavicle osteosynthesis using adaptable patient-specific instruments
    Roner, S.
    Bersier, P.
    Fuernstahl, P.
    Vlachopoulos, L.
    Schweizer, A.
    Wieser, K.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [9] 3D planning and surgical navigation of clavicle osteosynthesis using adaptable patient-specific instruments
    S. Roner
    P. Bersier
    P. Fürnstahl
    L. Vlachopoulos
    A. Schweizer
    K. Wieser
    Journal of Orthopaedic Surgery and Research, 14
  • [10] Evaluation of the accuracy of 3D-printed patient-specific osteotomy templates in pelvic tumor resection and reconstruction
    Zhao, Lulu
    Zhang, Zhengjia
    Zhou, Xin
    Li, Xiaomin
    Wu, Wen
    Ai, Songtao
    LANGENBECKS ARCHIVES OF SURGERY, 2024, 409 (01)