How good is the ACR accreditation phantom for assessing image quality in digital mammography?'

被引:38
|
作者
Huda, W
Sajewicz, AM
Ogden, KM
Scalzetti, EM
Dance, DR
机构
[1] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
[2] Royal Marsden NHS Trust, Dept Med Phys, London, England
关键词
American College of Radiology (ACR) phantom; digital mammography; image quality; observer performance; radiation dose; radiographic techniques;
D O I
10.1016/S1076-6332(03)80345-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to evaluate the American College of Radiology (ACR) accreditation phantom for assessing image quality in digital mammography. Materials and Methods. Digital images were obtained of an ACR accreditation phantom at varying mAs (constant kVp) and varying kVp (constant mAs). The average glandular dose for a breast with 50% glandularity was determined for each technique factor. Images were displayed on a 5 mega-pixel monitor, with the window width and level settings individually optimized for viewing the fibers, specks, and masses in the ACR phantom. Digital images of the ACR phantom were presented in a random manner to eight observers, each of whom indicated the number of objects visible in each image. Results. Intraobserver variability was greater than interobserver variability for the detection of fibers and specks, but the reverse was true for the detection of masses. As the mAs increased, the number of fibers visible increased from less than one at 5 mAs to all six being visible at 80 mAs. The corresponding number of visible specks increased from 12 to 24, and the number of visible masses increased from 1.25 to about four. Above 26 kVp, object visibility was constant with increasing x-ray tube voltage. Reducing the x-ray tube voltage to 24 kVp, however, reduced the number of visible fibers from six to five, the number of visible specks from 24 to 21.1, and the number of visible masses from four to 3.1. Observer performance was approximately constant for average glandular doses greater than 1.6 mGy, so that the range of lesion delectability in the ACR phantom occurs at doses lower than those normally encountered in clinical practice. Conclusion. The current design of the ACR phantom is unsatisfactory for assessing image quality in digital mammography.
引用
收藏
页码:764 / 772
页数:9
相关论文
共 50 条
  • [21] SCORING OF IMAGE QUALITY PHANTOM FILMS IN MAMMOGRAPHY - REPLY
    LAW, J
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (763): : 641 - 641
  • [22] USE OF A MAMMOGRAPHY TEST PHANTOM FOR EVALUATING IMAGE QUALITY
    BUTLER, P
    SHUPING, R
    JANS, R
    HEALTH PHYSICS, 1977, 33 (06): : 654 - 654
  • [23] Why do mammography facilities fail clinical image review: An analysis of the database of the ACR-Mammography Accreditation Program?
    Bassett, LW
    Farria, DM
    Bansal, S
    Feig, SA
    Farquhar, M
    RADIOLOGY, 1999, 213P : 408 - 408
  • [24] Using the ACR CT accreditation phantom for routine image quality assurance on both CT and CBCT imaging systems in a radiotherapy environment
    Hobson, Maritza A.
    Soisson, Emilie T.
    Davis, Stephen D.
    Parker, William
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 226 - 239
  • [25] Improved image quality in digital mammography with image processing
    Baydush, AH
    Floyd, CE
    MEDICAL PHYSICS, 2000, 27 (07) : 1503 - 1508
  • [26] A TEST OBJECT FOR ASSESSING IMAGE QUALITY IN MAMMOGRAPHY
    WHITE, DR
    TUCKER, AK
    BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (628): : 331 - 335
  • [27] Comparing eDQE and eNEQ metrics - is there an alternative approach to assessing image quality in digital mammography?
    Wysocka-Rabin, Anna
    Dobrzynska, Magdalena
    Pasicz, Katarzyna
    Skrzynski, Witold
    Fabiszewska, Ewa
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (03): : 165 - 177
  • [28] Initial image quality and clinical experience with new CR digital mammography system:: A phantom and clinical study
    Gaona, Enrique
    Alvarez Alfonso, Beatriz Y.
    Casian Castellanos, Gustavo
    Franco Enriquez, Jesus Gabriel
    MEDICAL PHYSICS, 2008, 1032 : 237 - 239
  • [29] A new test phantom with different breast tissue compositions for image quality assessment in conventional and digital mammography
    Pachoud, M
    Lepori, D
    Valley, JF
    Verdun, FR
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (23): : 5267 - 5281
  • [30] An Image Quality Assurance Phantom for Positron Emission Mammography (PEM)
    Luo, W.
    Disher, N.
    Lu, X.
    MEDICAL PHYSICS, 2011, 38 (06)