Effects of Intraluminal Thrombus on Patient-Specific Abdominal Aortic Aneurysm Hemodynamics via Stereoscopic Particle Image Velocity and Computational Fluid Dynamics Modeling

被引:36
|
作者
Chen, Chia-Yuan [1 ]
Anton, Raul [2 ]
Hung, Ming-yang [3 ]
Menon, Prahlad [3 ]
Finol, Ender A. [4 ]
Pekkan, Kerem [3 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 70101, Taiwan
[2] Tecnun Univ Navarra, Dept Mech Engn, Navarra 20018, Spain
[3] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15219 USA
[4] Univ Texas San Antonio, Dept Biomed Engn, San Antonio, TX 78249 USA
基金
美国国家卫生研究院;
关键词
stereoscopic particle image velocimetry (PIV); abdominal aortic aneurysm (AAA); thrombus; blood flow; vortex; wall shear stress; Computational fluid dynamics validation; WALL STRESS; BLOOD-FLOW; PATHOGENESIS; ASYMMETRY; PROGRAM;
D O I
10.1115/1.4026160
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The pathology of the human abdominal aortic aneurysm (AAA) and its relationship to the later complication of intraluminal thrombus (ILT) formation remains unclear. The hemodynamics in the diseased abdominal aorta are hypothesized to be a key contributor to the formation and growth of ILT. The objective of this investigation is to establish a reliable 3D flow visualization method with corresponding validation tests with high confidence in order to provide insight into the basic hemodynamic features for a better understanding of hemodynamics in AAA pathology and seek potential treatment for AAA diseases. A stereoscopic particle image velocity (PIV) experiment was conducted using transparent patient-specific experimental AAA models (with and without ILT) at three axial planes. Results show that before ILT formation, a 3D vortex was generated in the AAA phantom. This geometry-related vortex was not observed after the formation of ILT, indicating its possible role in the subsequent appearance of ILT in this patient. It may indicate that a longer residence time of recirculated blood flow in the aortic lumen due to this vortex caused sufficient shear-induced platelet activation to develop ILT and maintain uniform flow conditions. Additionally, two computational fluid dynamics (CFD) modeling codes (Fluent and an in-house cardiovascular CFD code) were compared with the two-dimensional, three-component velocity stereoscopic PIV data. Results showed that correlation coefficients of the out-of-plane velocity data between PIV and both CFD methods are greater than 0.85, demonstrating good quantitative agreement. The stereoscopic PIV study can be utilized as test case templates for ongoing efforts in cardiovascular CFD solver development. Likewise, it is envisaged that the patient-specific data may provide a benchmark for further studying hemodynamics of actual AAA, ILT, and their convolution effects under physiological conditions for clinical applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Patient-Specific Characterization of Breast Cancer Hemodynamics Using Image-Guided Computational Fluid Dynamics
    Wu, Chengyue
    Hormuth, David A.
    Oliver, Todd A.
    Pineda, Federico
    Lorenzo, Guillermo
    Karczmar, Gregory S.
    Moser, Robert D.
    Yankeelov, Thomas E.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (09) : 2760 - 2771
  • [22] Prediction of wall stress and oxygen flow in patient-specific abdominal aortic aneurysms: the role of intraluminal thrombus
    Alexis Throop
    Martina Bukac
    Rana Zakerzadeh
    Biomechanics and Modeling in Mechanobiology, 2022, 21 : 1761 - 1779
  • [23] Patient-specific assessment of hemodynamics by computational fluid dynamics in patients with bicuspid aortopathy
    Kimura, Naoyuki
    Nakamura, Masanori
    Komiya, Kenji
    Nishi, Satoshi
    Yamaguchi, Atsushi
    Tanaka, Osamu
    Misawa, Yoshio
    Adachi, Hideo
    Kawahito, Koji
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (04): : S52 - +
  • [24] Abdominal Aortic Aneurysm Endovascular Repair: Profiling Postimplantation Morphometry and Hemodynamics With Image-Based Computational Fluid Dynamics
    Tasso, Paola
    Raptis, Anastasios
    Matsagkas, Mitiadis
    Rizzini, Maurizio Lodi
    Gallo, Diego
    Xenos, Michalis
    Morbiducci, Umberto
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (11):
  • [25] Influence of IABP-Induced Abdominal Occlusions on Aortic Hemodynamics: A Patient-Specific Computational Evaluation
    Caruso, Maria Vitoria
    Renzuli, Attilio
    Fragomeni, Gionata
    ASAIO JOURNAL, 2017, 63 (02) : 161 - 167
  • [26] MANUFACTURING AND COMPUTATIONAL FLUID DYNAMICS MODELING OF A PATIENT-SPECIFIC FISTULA MODEL
    Liu, Yang
    Zheng, Yihao
    Pitre, John
    Weitzel, William
    Bull, Joseph
    Shih, Albert
    PROCEEDINGS OF THE ASME 12TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE - 2017, VOL 4, 2017,
  • [27] Local Morphologic and Hemodynamic Analyses for the Prediction of Abdominal Aortic Aneurysm Rupture Based on Patient-Specific CTA and Computational Modeling
    Wang, Jian
    Chen, Bing
    Bai, Zhixuan
    Yang, Tingting
    Gao, Fan
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [28] Measuring and modeling patient-specific distributions of material properties in abdominal aortic aneurysm wall
    C. Reeps
    A. Maier
    J. Pelisek
    F. Härtl
    V. Grabher-Meier
    W. A. Wall
    M. Essler
    H.-H. Eckstein
    M. W. Gee
    Biomechanics and Modeling in Mechanobiology, 2013, 12 : 717 - 733
  • [29] Measuring and modeling patient-specific distributions of material properties in abdominal aortic aneurysm wall
    Reeps, C.
    Maier, A.
    Pelisek, J.
    Haertl, F.
    Grabher-Meier, V.
    Wall, W. A.
    Essler, M.
    Eckstein, H. -H.
    Gee, M. W.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2013, 12 (04) : 717 - 733
  • [30] A patient-specific computational model of fluid-structure interaction in abdominal aortic aneurysms
    Wolters, BJBM
    Rutten, MCM
    Schurink, GWH
    Kose, U
    de Hart, J
    van de Vosse, FN
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (10) : 871 - 883