Comparison of full-field digital and screen-film mammography dose

被引:0
|
作者
Schueler, B. [1 ]
机构
[1] Mayo Clin, Rochester, MN USA
关键词
D O I
10.1118/1.2240277
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
下载
收藏
页码:2005 / 2005
页数:1
相关论文
共 50 条
  • [21] Comparison of the microcalcifications between full-field digital mammography and screen film mammography
    Tohno, E
    Kujiraoka, Y
    Watanabe, Y
    Itai, Y
    RADIOLOGY, 2001, 221 : 189 - 189
  • [22] SCREEN-FILM VERSUS FULL-FIELD DIGITAL MAMMOGRAPHY: RADIATION DOSE AND IMAGE QUALITY IN A LARGE TEACHING HOSPITAL
    Stantic, Tomislav J.
    Ciraj-Bjelac, Olivera E.
    Stojanovic, Saida S.
    Basta-Nikolic, Marijana D.
    Arandjic, Danijela D.
    Stoiljkovic, Dragana S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2013, 28 (04): : 398 - 405
  • [23] Comparison of radiation dose using full field digital and conventional screen-film mammography in a screening clinic
    Gingold, E
    MEDICAL PHYSICS, 2005, 32 (06) : 2100 - 2100
  • [24] Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched mean glandular dose
    Hendrick, RE
    Berns, EA
    RADIOLOGY, 2001, 221 : 338 - 339
  • [25] Comparison of full-field digital mammography with screen-film mammography for cancer detection: Results of 4,945 paired examinations
    Lewin, JM
    Hendrick, RE
    D'Orsi, CJ
    Isaacs, PK
    Moss, LJ
    Karellas, A
    Sisney, GA
    Kuni, CC
    Cutter, GR
    RADIOLOGY, 2001, 218 (03) : 873 - 880
  • [26] Comparison of full-field digital mammography to screen-film mammography with respect to contrast and spatial resolution in tissue equivalent breast phantoms
    Kuzmiak, CM
    Pisano, ED
    Cole, EB
    Zeng, DL
    Burns, CB
    Roberto, C
    Pavic, D
    Lee, Y
    Seo, BK
    Koomen, M
    Washburn, D
    MEDICAL PHYSICS, 2005, 32 (10) : 3144 - 3150
  • [27] Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched average glandular dose
    Berns, EA
    Hendrick, RE
    Cutter, GR
    MEDICAL PHYSICS, 2003, 30 (03) : 334 - 340
  • [28] Full-field digital versus screen-film mammography: Comparative accuracy in concurrent screening cohorts
    Del Turco, Marco Rosselli
    Mantellini, Paola
    Ciatto, Stefano
    Bonardi, Rita
    Martinelli, Francesca
    Lazzari, Barbara
    Houssami, Nehmat
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) : 860 - 866
  • [29] Studies Comparing Screen-Film Mammography and Full-Field Digital Mammography in Breast Cancer Screening: Updated Review
    Skaane, P.
    ACTA RADIOLOGICA, 2009, 50 (01) : 3 - 14
  • [30] Observer variability in screen-film mammography versus full-field digital mammography with soft-copy reading
    Per Skaane
    Felix Diekmann
    Corinne Balleyguier
    Susanne Diekmann
    Jean-Charles Piguet
    Kari Young
    Michael Abdelnoor
    Loren Niklason
    European Radiology, 2008, 18