Discount Counting for Fast Flow Statistics on Flow Size and Flow Volume

被引:30
|
作者
Hu, Chengchen [1 ]
Liu, Bin [2 ]
Zhao, Hongbo [3 ]
Chen, Kai [4 ]
Chen, Yan [5 ]
Cheng, Yu [6 ]
Wu, Hao [2 ]
机构
[1] Xi An Jiao Tong Univ, Dept Comp Sci & Technol, MOE KLINNS Lab, Xian 710000, Peoples R China
[2] Tsinghua Univ, Dept Comp Sci & Technol, Beijing 100084, Peoples R China
[3] MeshSr Co Ltd, Nanjing 211100, Jiangsu, Peoples R China
[4] Hong Kong Univ Sci & Technol, Dept Comp Sci & Engn, Hong Kong, Hong Kong, Peoples R China
[5] Northwestern Univ, Dept Elect Engn & Comp Sci, Evanston, IL 60208 USA
[6] IIT, Dept Elect & Comp Engn Technol, Chicago, IL 60616 USA
基金
美国国家科学基金会;
关键词
Counter; flow statistics; network measurement; unbiased estimation; ARCHITECTURE;
D O I
10.1109/TNET.2013.2270439
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
A complete flow statistics report should include both flow size (the number of packets in a flow) counting and flow volume (the number of bytes in a flow) counting. Although previous studies have contributed a lot to the flow size counting problem, it is still a great challenge to well support the flow volume statistics due to the demanding requirements on both memory size and memory bandwidth in monitoring device. In this paper, we propose a DIScount COunting (DISCO) method, which is designed for both flow size and flow bytes counting. For each incoming packet of length, DISCO increases the corresponding counter assigned to the flow with an increment that is less than. With an elaborate design on the counter update rule and the inverse estimation, DISCO saves memory consumption while providing an accurate unbiased estimator. The method is evaluated thoroughly under theoretical analysis and simulations with synthetic and real traces. The results demonstrate that DISCO is more accurate than related work given the same counter sizes. DISCO is also implemented on the network processor Intel IXP2850 for a performance test. Using only one microengine (ME) in IXP2850, the throughput can reach up to 11.1 Gb/s under a traditional traffic pattern. The throughput increases to 39 Gb/s when employing four MEs.
引用
收藏
页码:970 / 981
页数:12
相关论文
共 50 条
  • [21] FAST AND EXACT FLOW MEASUREMENTS WITH THE FAST FOURIER FLOW TECHNIQUE
    HENNIG, J
    MUERI, M
    BRUNNER, P
    FRIEDBURG, H
    MAGNETIC RESONANCE IMAGING, 1988, 6 (04) : 369 - 372
  • [22] High accuracy volume flow rate measurement using vortex counting
    Zaaraoui, A.
    Ravelet, F.
    Margnat, E.
    Khelladi, S.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 33 : 138 - 144
  • [23] Small, inexpensive flow cytometer automates fast tumor cell counting
    不详
    LASER FOCUS WORLD, 2015, 51 (08): : 58 - 58
  • [24] Sinusoidal Flow: A Fast Invertible Autoregressive Flow
    Wei, Yumou
    ASIAN CONFERENCE ON MACHINE LEARNING, VOL 157, 2021, 157 : 299 - 314
  • [25] THE SELF-COUNTING FLOW
    Schumacher, Raphael
    FIBONACCI QUARTERLY, 2022, 60 (05): : 324 - 343
  • [26] Counting on Faster Flow Cytometry
    Raper V.
    Raper, Vivienne, 1600, Mary Ann Liebert Inc. (37): : 1and6 - 7
  • [27] DROP COUNTING FLOW COMPUTER
    BURGAR, CG
    WINTER, GJ
    SHEPHERD, AP
    AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 248 (02): : H286 - H290
  • [28] Improving Packet Flow Counting With Fingerprint Counting
    Reviriego, Pedro
    Martinez, Jorge
    Pontarelli, Salvatore
    IEEE COMMUNICATIONS LETTERS, 2020, 24 (01) : 76 - 80
  • [29] Discount Cash Flow model for business evaluation
    Zhao, H
    Wang, L
    Proceedings of the 2005 International Conference on Management Science and Engineering, 2005, : 666 - 670
  • [30] Subjective Cash Flow and Discount Rate Expectations
    De La O, Ricardo
    Myers, Sean
    JOURNAL OF FINANCE, 2021, 76 (03): : 1339 - 1387