High accuracy volume flow rate measurement using vortex counting

被引:5
|
作者
Zaaraoui, A. [1 ]
Ravelet, F. [2 ]
Margnat, E. [2 ]
Khelladi, S. [2 ]
机构
[1] Univ Khemis Meliana, Lab Fluides Ind Mesures & Applicat, Meliana, Algeria
[2] Arts & Metiers ParisTech, DynFluid Lab, F-75013 Paris, France
关键词
Wake; Bluff body; Accuracy Strain gauges sensor; Vortex shedding; Digital volume; BLUFF-BODY; FLOWMETER; SIGNAL; UNCERTAINTY; VIBRATIONS; BODIES; NUMBER;
D O I
10.1016/j.flowmeasinst.2013.06.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A prototype device for measuring the volumetric flow-rate by counting vortices has been designed and realized. It consists of a square-section pipe in which a two-dimensional bluff body and a strain gauge force sensor are placed. These two elements are separated from each other, unlike the majority of vortex apparatus currently available. The principle is based on the generation of a separated wake behind the bluff body. The volumetric flow-rate measurement is done by counting vortices using a flat plate placed in the wake and attached to the beam sensor. By optimizing the geometrical arrangement, the search for a significant signal has shown that it was possible to get a quasi-periodic signal, within a good range of flow rates so that its performances are well deduced. The repeatability of the value of the volume of fluid passed for every vortex shed is tested for a given flow and then the accuracy of the measuring device is determined. This quantity is the constant of the device and is called the digital volume (Vu). It has the dimension of a volume and varies with the confinement of the flow and with the Reynolds number. Therefore, a dimensionless quantity is introduced, the reduced digital volume (V-r) that takes into account the average speed in the contracted section downstream of the bluff body. The reduced digital volume is found to be independent of the confinement in a significant range of Reynolds numbers, which gives the device a good accuracy. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 50 条
  • [1] VORTEX METERS - HIGH-ACCURACY FLOW MEASUREMENT
    OCONNOR, L
    MECHANICAL ENGINEERING, 1991, 113 (10) : 46 - 49
  • [2] MEASUREMENT OF THE FLOW RATE AND VOLUME VOID FRACTION OF GAS-LIQUID BUBBLE FLOW USING A VORTEX FLOW METER
    Sun, Zhiqiang
    Zhang, Hongjian
    CHEMICAL ENGINEERING COMMUNICATIONS, 2010, 197 (02) : 145 - 157
  • [3] Measurement of mass flow rate using a vortex flowmeter
    Huang, YM
    Zhang, HJ
    Sun, ZQ
    PROCEEDINGS OF THE IEEE SENSORS 2003, VOLS 1 AND 2, 2003, : 344 - 347
  • [4] A COUNTING-RATE METER OF HIGH ACCURACY
    COOKEYARBOROUGH, EH
    PULSFORD, EW
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1951, 98 (62): : 191 - &
  • [5] Flow rate measurement in a pipe flow by vortex shedding
    Reik, M.
    Hoecker, R.
    Bruzzese, C.
    Hollmach, M.
    Koudal, O.
    Schenkel, T.
    Oertel, H.
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 2010, 74 (02): : 77 - 86
  • [6] Measurement of flow rate using temperature fluctuation caused by vortex street
    Michiyoshi, I
    Ohtsubo, A
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1970, 7 (10): : 511 - 517
  • [7] ACCURACY AND REPRODUCIBILITY OF A MEASUREMENT USING HIGH-VOLUME SYRINGES
    Ferrandez Javier, Sanchez-Rubio
    Perez Virginia, Garcia
    Nieto Olga, Casado
    Maria Auxiliadora, Caro Manzanero
    Cabanillas Elisa, Martin-Pintado
    Gonzalez Alexandra, Monco
    Diaz Raquel, Moreno
    ATENCION FARMACEUTICA, 2012, 14 (05): : 379 - 382
  • [8] Influence of the wetness on flow rate measurement of wet steam using a vortex flow meter
    Umezawa, Shuichi
    Shimada, Hiroyuki
    Morita, Ryo
    Inada, Fumio
    Uchiyama, Yuta
    Ishibashi, Masahiro
    Funaki, Tatsuya
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2013, 79 (799): : 415 - 422
  • [9] FLOW AND VOLUME METERING USING THE VORTEX EFFECT
    BOURAS, C
    COMOLET, R
    REVUE GENERALE DE THERMIQUE, 1985, 24 (279): : 253 - 256
  • [10] ACCURACY OF DUPLEX SCANNING FOR MEASUREMENT OF ARTERIAL VOLUME FLOW
    ZIERLER, BK
    KIRKMAN, TR
    KRAISS, LW
    REISS, WG
    HORN, JR
    BAUER, LA
    CLOWES, AW
    KOHLER, TR
    JOURNAL OF VASCULAR SURGERY, 1992, 16 (04) : 520 - 526