-30 °C to 960 °C to Variable Temperature Blackbody (VTBB) Radiance Temperature Calibration Facility

被引:0
|
作者
Yuan, Z. [1 ]
Wang, J. [1 ]
Hao, X. [1 ]
Wang, T. [1 ]
Dong, W. [1 ]
机构
[1] Natl Inst Metrol, Div Thermophys & Proc Measurements, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
Emissivity; Heat pipe; Multi-wavelength effective radiance temperature calibration; Radiation thermometry; Uncertainty; Variable temperature blackbody; THERMOMETRY;
D O I
10.1007/s10765-015-1989-x
中图分类号
O414.1 [热力学];
学科分类号
摘要
A blackbody radiance temperature calibration facility (RTCF) has recently been established at the National Institute of Metrology, China, offering calibration and verification services for variable temperature blackbody (VTBB) radiation sources. The RTCF includes reference VTBBs in the range of to and consists of a stirred liquid bath blackbody of to and water, cesium, and sodium heat-pipe blackbodies spanning to . In addition, the facility is equipped with a set of radiation thermometers with different working wavelengths (or wavebands); these thermometers are used to transfer radiance temperatures from the reference to customers' VTBBs. Cavities with V-notch grooves in the inner surface have an estimated emissivity from 0.99986 to 0.99994. The temperature control stability and temperature uniformity of VTBBs are characterized. Furthermore, we test the difference between a cavity and thermometer well temperatures and compare the radiance temperatures of the Cs and Na heat-pipe blackbodies. The expanded uncertainty of VTBBs' radiance temperatures at ( to ) is evaluated from to . The facility has been used to calibrate and characterize customers' VTBBs.
引用
收藏
页码:3297 / 3309
页数:13
相关论文
共 50 条
  • [21] Bionic Metamaterial Microwave Blackbody with Temperature Insensitivity for C ∼ Ku Bands
    Qiao, Mengke
    Li, Xiangcheng
    Chen, Pingan
    Zhu, Yingli
    PLASMONICS, 2024, 19 (05) : 2537 - 2543
  • [22] High emissivity blackbody for radiometric calibration near ambient temperature
    Té, Y
    Jeseck, P
    Camy-Peyret, C
    Payan, S
    Briaudeau, S
    Fanjeaux, M
    METROLOGIA, 2003, 40 (02) : 24 - 30
  • [23] Temperature dependence of the thermoelectric inhomogeneity for type B thermocouples from 180°C to 960°C
    Kim, Yong-Gyoo
    Lee, Young Hee
    Joung, Wukchul
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (05)
  • [24] Comparison of Blackbody Sources for Low-Temperature IR Calibration
    Ljungblad, S.
    Holmsten, M.
    Josefson, L. E.
    Klason, P.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (12) : 3310 - 3319
  • [25] Comparison of Blackbody Sources for Low-Temperature IR Calibration
    S. Ljungblad
    M. Holmsten
    L. E. Josefson
    P. Klason
    International Journal of Thermophysics, 2015, 36 : 3310 - 3319
  • [26] DSC temperature calibration over the range −125 °C to 50 °C
    Ashton, Gage P.
    Charsley, Edward L.
    Harding, Lindsay P.
    Parkes, Gareth M.B.
    Thermochimica Acta, 2021, 698
  • [27] Development and characterisation of a bath-based vertical blackbody cavity calibration source for the range-30 °C to 150 °C
    Boles, Sam
    Pusnik, Igor
    Mac Lochlainn, Dubhaltach
    Fleming, David
    Naydenova, Izabela
    Martin, Suzanne
    MEASUREMENT, 2017, 106 : 121 - 127
  • [28] Water heat pipe blackbody as a reference spectra radiance source between 50°C and 250°C
    Noorma, M.
    Mekhontsev, S.
    Khromchenko, V.
    Litorja, M.
    Cagran, C.
    Zeng, J.
    Hanssen, L.
    THERMOSENSE XXVIII, 2006, 6205
  • [29] Spaceborne radiance temperature standard blackbody for Chinese high-precision infrared spectrometer
    Hao, Xiaopeng
    Song, Jian
    Ding, Lei
    Wen, Ping
    Sun, Jianping
    Liu, Yang
    Yuan, Zundong
    Duan, Yuning
    Zhang, Yong
    METROLOGIA, 2020, 57 (06)
  • [30] A method to retrieve blackbody temperature errors in the two points radiometric calibration
    Te, Yao
    Jeseck, Pascal
    Pepin, Isabelle
    Camy-Peyret, Claude
    INFRARED PHYSICS & TECHNOLOGY, 2009, 52 (05) : 187 - 192