Comparison of Blackbody Sources for Low-Temperature IR Calibration

被引:0
|
作者
S. Ljungblad
M. Holmsten
L. E. Josefson
P. Klason
机构
[1] SP Technical Research Institute of Sweden,
来源
关键词
Blackbody; IR calibration; Radiation thermometry;
D O I
暂无
中图分类号
学科分类号
摘要
Radiation thermometers are traditionally mostly used in high-temperature applications. They are, however, becoming more common in different applications at room temperature or below, in applications such as monitoring frozen food and evaluating heat leakage in buildings. To measure temperature accurately with a pyrometer, calibration is essential. A problem with traditional, commercially available, blackbody sources is that ice is often formed on the surface when measuring temperatures below 0∘C\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0\,{}^{\circ }\hbox {C}$$\end{document}. This is due to the humidity of the surrounding air and, as ice does not have the same emissivity as the blackbody source, it biases the measurements. An alternative to a traditional blackbody source has been tested by SP Technical Research Institute of Sweden. The objective is to find a cost-efficient method of calibrating pyrometers by comparison at the level of accuracy required for the intended use. A disc-shaped blackbody with a surface pyramid pattern is placed in a climatic chamber with an opening for field of view of the pyrometer. The temperature of the climatic chamber is measured with two platinum resistance thermometers in the air in the vicinity of the disc. As a rule, frost will form only if the deposition surface is colder than the surrounding air, and, as this is not the case when the air of the climatic chamber is cooled, there should be no frost or ice formed on the blackbody surface. To test the disc-shaped blackbody source, a blackbody cavity immersed in a conventional stirred liquid bath was used as a reference blackbody source. Two different pyrometers were calibrated by comparison using the two different blackbody sources, and the results were compared. The results of the measurements show that the disc works as intended and is suitable as a blackbody radiation source.
引用
收藏
页码:3310 / 3319
页数:9
相关论文
共 50 条
  • [1] Comparison of Blackbody Sources for Low-Temperature IR Calibration
    Ljungblad, S.
    Holmsten, M.
    Josefson, L. E.
    Klason, P.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (12) : 3310 - 3319
  • [2] LOW-TEMPERATURE BLACKBODY
    PAVLYUKOV, AK
    KHOLOPOV, GK
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (03) : 854 - 855
  • [3] A High-Emissivity Blackbody with Large Aperture for Radiometric Calibration at Low-Temperature
    Ko, Hsin-Yi
    Wen, Bor-Jiunn
    Tsa, Shu-Fei
    Li, Guo-Wei
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2009, 30 (01) : 98 - 104
  • [4] A High-Emissivity Blackbody with Large Aperture for Radiometric Calibration at Low-Temperature
    Hsin-Yi Ko
    Bor-Jiunn Wen
    Shu-Fei Tsa
    Guo-Wei Li
    [J]. International Journal of Thermophysics, 2009, 30 : 98 - 104
  • [5] Blackbody calibration sources
    Merchant, J
    [J]. MEASUREMENTS & CONTROL, 1996, (175): : 114 - 117
  • [6] IR spectral characterization of customer blackbody sources: first calibration results
    Mekhontsev, S.
    Noorma, M.
    Prokhorov, A.
    Hanssen, L.
    [J]. THERMOSENSE XXVIII, 2006, 6205
  • [7] Spectroradiometric calibration of blackbody sources
    Madding, RP
    [J]. THERMOSENSE XXIII, 2001, 4360 : 363 - 371
  • [8] LOW-TEMPERATURE BLACKBODY BASED ON THERMOELECTRIC REFRIGERATOR
    KOGAN, AV
    KOLENKO, EA
    NECHAI, ES
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (06): : 1439 - &
  • [9] A Low-temperature Blackbody Source from-30 °C to 30 °C for Industrial Calibration
    Knazovicka, L.
    Strnad, R.
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 678 - 681
  • [10] Uncertainties in blackbody corrections for low-temperature radiation thermometers
    Saunders, P.
    Manoi, A.
    [J]. METROLOGIA, 2020, 57 (02)