Errors induced by spectral measurement positions and instrument noise in soil organic carbon prediction using vis-NIR on intact soil

被引:5
|
作者
Sun, Xiao-Lin [1 ]
机构
[1] Sun Yat Sen Univ, Sch Geog & Planning, Guangzhou 510275, Peoples R China
基金
中国国家自然科学基金;
关键词
Soil spectroscopy; Error analysis; Sampling positions; Instrument noise; DIFFUSE-REFLECTANCE SPECTROSCOPY; IN-SITU; NEURAL-NETWORK; LEAST-SQUARES; CLAY CONTENT; MOISTURE; FIELD; PROPAGATION; ACCURACY;
D O I
10.1016/j.geoderma.2020.114731
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Soil spectroscopy potentially would become a routine method for the measurement of soil properties in the field on soil cores. However, many factors could lead to errors in the measurement of spectra from intact soil cores. So far, errors induced by spectral measurement positions and instrument noise have rarely been quantified. The present study evaluated these errors based on 160 intact ring core samples collected from 20 profiles in a forest, southwest China. Each ring sample was scanned using a visible near-infrared (vis-NIR) spectrometer at nine evenly distributed positions at both ends of the ring to characterize within-sample variability. In addition, 10 scans were made at each position to characterize instrument error. A position spectrum was then calculated by averaging the 10 scans at each position, while a sample spectrum was calculated by averaging all 180 scans of each sample. The samples were then tested for soil organic carbon (SOC) content using the wet oxidation method. Based on the sample spectra and SOC content, a partial least squares regression (PLSR) model was calibrated. The modeling error was empirically calculated. Each scan, position spectrum, and sample spectrum was then fed into the calibrated PLSR model to predict SOC content, and the prediction results were evaluated for errors induced by instrument noise and different spectral measurement positions. Results showed that the error induced by different spectral measurement positions was about 75% of the modeling error, while the error induced by instrument noise was small and negligible. These three errors in terms of standard error of prediction (SEP) accounted for 18.6%, 23.8% and 1.46% of the average measured SOC content of the samples, respectively. Besides, the error due to different soil core sampling positions was also considerable. In terms of SEP, this error accounted for 12.5% of the average measured SOC content. These quantified error budgets would help to account for uncertainty in the measurement of soil properties using spectroscopy in the field.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Prediction of soil organic carbon for different levels of soil moisture using Vis-NIR spectroscopy
    Nocita, Marco
    Stevens, Antoine
    Noon, Carole
    van Wesemael, Bas
    GEODERMA, 2013, 199 : 37 - 42
  • [2] Soil Organic Carbon Prediction Using Vis-NIR Spectroscopy with a Large Dataset
    Shi, Yang
    Wang, Rujing
    Wang, Yubing
    COMPUTER AND COMPUTING TECHNOLOGIES IN AGRICULTURE XI, PT I, 2019, 545 : 76 - 86
  • [3] Selection of "Local" Models for Prediction of Soil Organic Matter Using a Regional Soil Vis-NIR Spectral Library
    Zeng, Rong
    Zhao, Yu-Guo
    Li, De-Cheng
    Wu, Deng-Wei
    Wei, Chang-Long
    Zhang, Gan-Lin
    SOIL SCIENCE, 2016, 181 (01) : 13 - 19
  • [4] Analyzing Errors due to Measurement Positions and Sampling Locations for In Situ Measurements of Soil Organic Matter Using Vis-NIR Spectroscopy
    Zhang Hao-dan
    Sun Xiao-lin
    Wang Xiao-qing
    Wang Hui-li
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (11) : 3499 - 3507
  • [5] Development of a Danish national Vis-NIR soil spectral library for soil organic carbon determination
    Knadel, M.
    Deng, F.
    Thomsen, A.
    Greve, M. H.
    DIGITAL SOIL ASSESSMENTS AND BEYOND, 2012, : 403 - 408
  • [6] Prediction of soil organic carbon in a coal mining area by Vis-NIR spectroscopy
    Sun, Wenjuan
    Li, Xinju
    Niu, Beibei
    PLOS ONE, 2018, 13 (04):
  • [7] Sampling for field measurement of soil carbon using Vis-NIR spectroscopy
    Singh, Kanika
    Minasny, Budiman
    McBratney, Alex B.
    Short, Michael G.
    Namazi, Fatemeh
    DIGITAL SOIL ASSESSMENTS AND BEYOND, 2012, : 415 - 420
  • [8] Global Soil Salinity Prediction by Open Soil Vis-NIR Spectral Library
    Zhou, Yin
    Chen, Songchao
    Hu, Bifeng
    Ji, Wenjun
    Li, Shuo
    Hong, Yongsheng
    Xu, Hanyi
    Wang, Nan
    Xue, Jie
    Zhang, Xianglin
    Xiao, Yi
    Shi, Zhou
    REMOTE SENSING, 2022, 14 (21)
  • [9] Soil Organic Carbon Prediction Based on Vis-NIR Spectral Classification Data Using GWPCA-FCM Algorithm
    Miao, Yutong
    Wang, Haoyu
    Huang, Xiaona
    Liu, Kexin
    Sun, Qian
    Meng, Lingtong
    Xu, Dongyun
    SENSORS, 2024, 24 (15)
  • [10] On-line vis-NIR spectroscopy prediction of soil organic carbon using machine learning
    Nawar, S.
    Mouazen, A. M.
    SOIL & TILLAGE RESEARCH, 2019, 190 : 120 - 127