Performances of capillary X-ray optics for confocal three-dimensional micro-X-ray fluorescence technology

被引:12
|
作者
Sun, Tianxi [1 ,2 ,3 ]
Liu, Zhiguo [1 ,2 ,3 ]
Li, Yude [1 ,2 ,3 ]
Zhu, Guanghua [1 ,2 ,3 ]
Lin, Xiaoyan [1 ,2 ,3 ]
Luo, Ping [1 ,2 ,3 ]
Pan, Qiuli [1 ,2 ,3 ]
Liu, Hui [1 ,2 ,3 ]
Teng, Yuepeng [1 ,2 ,3 ]
Yang, Ke [1 ,2 ,3 ]
Ding, Xunliang [1 ,2 ,3 ]
机构
[1] Beijing Normal Univ, Key Lab Beam Technol & Mat Modificat, Minist Educ, Beijing 100875, Peoples R China
[2] Beijing Normal Univ, Coll Nucl Sci & Technol, Beijing 100875, Peoples R China
[3] Beijing Radiat Ctr, Beijing 100875, Peoples R China
基金
高等学校博士学科点专项科研基金;
关键词
Capillary X-ray optics; Confocal 3D Micro-XRF; Performance study; PAINT LAYERS; DEPTH; LENS;
D O I
10.1016/j.nima.2009.05.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performances of capillary X-ray optics (CXRO) for confocal three-dimensional micro-X-ray fluorescence (3D Micro-XRF) technology are presented. In particular, the energy dependence of the collecting angle and input focal spot size of the polycapillary parallel X-ray lens (PPXRL), and the energy dependence of spatial resolution of the confocal 3D Micro-XRF spectrometer based on the CXRO are reported. In order to obtain the input focal spot size of the PPXRL, the source scan method was used. The size of the input focal spot of the PPXRL was 25.5 mu m at 13 keV, and it was close to that of the output focal spot of a polycapillary focusing X-ray lens (PFXRL) at the same energy. The collecting angle of the PPXRL was 110mrad at 10keV, and it decreased with the increasing energies. The depth spatial resolution of the confocal 3D Micro-XRF spectrometer based on the CXRO was 29.3 mu m at 17 keV, and it decreased with the increasing energies. The minimal detection limit of this confocal 3D Micro-XRF spectrometer was 101 ppm for the Ti-K alpha, when the operating voltage and current of the Mo X-ray tube were 36.0 kV and 800.0 mu A, respectively. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:829 / 832
页数:4
相关论文
共 50 条
  • [41] Review on the Application of Micro-X-Ray Fluorescence Analysis Technology in China
    Wang Yi-ya
    Wang Yi-min
    Deng Sai-wen
    Gao Xin-hua
    Liang Guo-li
    Zhang Zhong
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (06) : 1728 - 1735
  • [42] Development of confocal micro X-ray fluorescence instrument using two X-ray beams
    Tsuji, Kouichi
    Nakano, Kazuhiko
    Ding, Xunliang
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (6-7) : 549 - 553
  • [43] A micro-fluorescent/diffracted x-ray spectrometer with a micro-x-ray beam formed by a fine glass capillary
    Yamamoto, N
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (09): : 3051 - 3064
  • [44] The surface morphology analysis based on progressive approximation method using confocal three-dimensional micro X-ray fluorescence
    Yi, Longtao
    Sun, Tianxi
    Wang, Kai
    Qin, Min
    Yang, Kui
    Wang, Jinbang
    Liu, Zhiguo
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 122 : 127 - 131
  • [45] X-ray fluorescence imaging with polycapillary X-ray optics
    Yonehara, Tasuku
    Yamaguchi, Makoto
    Tsuji, Kouichi
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (06) : 441 - 444
  • [46] Fundamental characteristics of hybrid X-ray focusing optics for micro X-ray fluorescence analysis
    Komatani, Shintaro
    Nakamachi, Kazuo
    Nakano, Kazuhiko
    Ohzawa, Sumito
    Uchihara, Hiroshi
    Bando, Atsushi
    Tsuji, Kouichi
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 260 - 263
  • [47] Processing of three-dimensional microscopic X-ray fluorescence data
    Vekemans, B
    Vincze, L
    Brenker, FE
    Adams, F
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (10) : 1302 - 1308
  • [48] Processing of three-dimensional microscopic X-ray fluorescence data
    [J]. Vekemans, B., 1600, Royal Society of Chemistry (19):
  • [49] Quantitative analysis of single aerosol particles with confocal micro-X-ray fluorescence spectrometer
    Sun, Tianxi
    Liu, Zhiguo
    Li, Yude
    Lin, Xiaoyan
    Wang, Guangfu
    Zhu, Guanghua
    Xu, Qing
    Luo, Ping
    Pan, Qiuli
    Liu, Hui
    Ding, Xunliang
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 295 - 297
  • [50] Investigation of polycapillary half lenses for quantitative confocal micro-X-ray fluorescence analysis
    Iro, Michael
    Ingerle, Dieter
    Radtke, Martin
    Buzanich, Ana Guilherme
    Kregsamer, Peter
    Streli, Christina
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 1376 - 1384