Fast alternative method for measuring the wavefront of lithography exposure systems

被引:1
|
作者
Kabardiadi, Alexander [1 ]
Assmann, Heiko [2 ]
Greiner, Andreas [2 ]
Baselt, Tobias [1 ]
Taudt, Christopher [1 ]
Hartmann, Peter [1 ]
机构
[1] West Saxon Univ Appl Sci Zwickau, D-08056 Zwickau, Germany
[2] Infineon Technol Dresden GmbH, D-01099 Dresden, Germany
关键词
Wavefront measurement; wavefront reconstruction; Zernike approximation; designing of a measurements; PSD evaluation;
D O I
10.1117/12.2195334
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The work presented here describes the analysis of problems of the realization of alternative wavefront measurement methods for lithography exposure machines. The measurement method that is introduced is a redesign of a conventional Shack-Hartmann wavefront sensor and was based on the usage of a single pinhole and the lithography machine itself. Such a redesign is useful because it increases the degrees of freedom. Therefore, there is more freedom to analyze the problems of designing and planning measurements. A group of hardware prototypes under laboratory conditions with the required angular and lateral resolution were realized. For the approximation of the measurement results, numerical simulations are implemented using the Monte-Carlo method in order to statistically design the experiments themselves.
引用
收藏
页数:7
相关论文
共 50 条
  • [22] Measuring of slip resistance - An alternative method
    Kleicke, Roland
    Klug, Peter
    Köckritz, Uwe
    Lotzmann, Hagen
    Raschdorf, Monika
    Cherif, Chokri
    Unitex, 2010, (03): : 21 - 22
  • [23] An Alternative Method for Measuring Financial Frictions
    Aysun, Uluc
    B E JOURNAL OF MACROECONOMICS, 2011, 11 (01):
  • [24] An alternative method of measuring the QT interval
    Gibb, W
    Westphal, N
    Jalali, L
    Bornzin, G
    Florio, J
    Park, E
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 641 - 645
  • [25] An alternative method for measuring scoliosis curvature
    Chen, Yi-Lang
    Chen, Wen-Jer
    Chiou, Wen-Ko
    ORTHOPEDICS, 2007, 30 (10) : 828 - 831
  • [26] Fast fabrication of silicon nanopillar array using electron beam lithography with two-layer exposure method
    Wang, Xiaodong
    Xu, Jian
    Quan, Xueling
    Li, Yaqian
    Wang, Ying
    Cheng, Xiulan
    MICROELECTRONIC ENGINEERING, 2020, 227
  • [27] Fast Mask Optimization Method for Extreme Ultraviolet Lithography
    Zhang Zinan
    Li Sikun
    Wang Xiangzhao
    Cheng Wei
    ACTA OPTICA SINICA, 2022, 42 (13)
  • [28] Fast Hologram Calculation Method Based on Wavefront Precise Diffraction
    Wang, Zimu
    Li, Yilong
    Tang, Zhenyan
    Li, Zhaosong
    Wang, Di
    MICROMACHINES, 2023, 14 (09)
  • [29] Fast Mask Optimization Method for Extreme Ultraviolet Lithography
    Zhang, Zinan
    Li, Sikun
    Wang, Xiangzhao
    Cheng, Wei
    Guangxue Xuebao/Acta Optica Sinica, 2022, 42 (13):
  • [30] Progress in the development of extreme ultraviolet lithography exposure systems
    Stulen, RH
    MICROELECTRONIC ENGINEERING, 1999, 46 (1-4) : 19 - 22