Digital gamma-ray tracking algorithms in segmented germanium detectors

被引:10
|
作者
Pearson, CJ [1 ]
Dobón, JJV
Regan, PH
Sellin, PJ
Morton, E
Nolan, PJ
Boston, A
Descovich, M
Thornhill, J
Cresswell, J
Lazarus, I
Simpson, J
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[2] Univ Liverpool, Dept Phys, Liverpool L69 3BX, Merseyside, England
[3] SERC, Daresbury Lab, CCLRC, Warrington WA4 4AD, Cheshire, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1109/TNS.2002.1039639
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A gamma-ray tracking algorithm has been. implemented and tested, using simulated data, for gamma rays with energies between 0.1 and 2 MeV, and its performance evaluated for a 90-mm-long, 60-mm-diameter, cylindrical, 36 (6 x 6) segment detector. The performance of the algorithm in two areas was determined: Compton suppression and Doppler shift correction. It was found that for gamma rays of energies around 1 MeV, a ratio of photopeak counts to total counts of 2 : 3, could be obtained using the tracking algorithm, with only a 2% reduction in detection efficiency, compared to the untracked data. Approximately 80% of first interaction points could be correctly identified, enabling a good Doppler shift correction. A detector of the type simulated has recently been delivered, together with a compactPCI digital data acquisition system comprising 36 12-bit, 40-MHz flash ADCs, and 6 200-MHz DSPs. Some initial data has been recorded using this system, and the performance of the tracking algorithm on this real data is comparable to its performance on simulated data.
引用
收藏
页码:1209 / 1215
页数:7
相关论文
共 50 条
  • [31] Identification of bremsstrahlung events in gamma-ray tracking detectors
    Tashenov, S.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [33] LARGE VOLUME LITHIUM-DRIFTED GERMANIUM GAMMA-RAY DETECTORS
    FIEDLER, HJ
    HUGHES, LB
    KENNETT, TJ
    PRESTWICH, WV
    WALL, BJ
    NUCLEAR INSTRUMENTS & METHODS, 1966, 40 (02): : 229 - +
  • [34] High-resolution gamma-ray spectroscopy of hypernuclei with germanium detectors
    Tanida, K
    Tamura, H
    Abe, D
    Ajimura, S
    Akikawa, P
    Araki, K
    Bhang, HC
    Chrien, RE
    Eugenio, P
    Frankling, GB
    Fujii, Y
    Fukuda, T
    Gan, L
    Hashimoto, O
    Hotchi, H
    Imai, K
    Kakiguchi, Y
    Khaustov, P
    Kim, JH
    Kim, YD
    Kohri, H
    May, M
    Miyoshi, T
    Murakami, T
    Nagae, T
    Nakano, J
    Noumi, H
    Ozawa, K
    Outa, H
    Pile, PH
    Quinn, BP
    Rusek, A
    Saito, T
    Sasao, J
    Sato, Y
    Satoh, S
    Sawafta, RI
    Schumacher, RA
    Sekimoto, M
    Takahashi, T
    Tamagawa, T
    Tang, L
    Xia, HH
    Yuan, L
    Zhou, SH
    Zhou, LH
    Zhu, XF
    NUCLEAR PHYSICS A, 2001, 684 : 560C - 562C
  • [35] 3-D positioning germanium detectors for gamma-ray astronomy
    Coburn, W
    Amrose, S
    Boggs, SE
    Lin, RP
    Amman, M
    Burks, MT
    Hull, EL
    Luke, PN
    Madden, N
    X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 : 54 - 63
  • [36] AUTOMATIC-ANALYSIS OF GAMMA-RAY SPECTRA FROM GERMANIUM DETECTORS
    PHILLIPS, GW
    MARLOW, KW
    NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (03): : 525 - 536
  • [37] THE NEED FOR CYLINDRICAL GERMANIUM GAMMA-RAY DETECTORS WITH ACCURATELY SPECIFIED DIMENSIONS
    MOENS, L
    DEBERTIN, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 238 (01): : 180 - 181
  • [38] Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy
    Amman, M
    Luke, PN
    HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 : 144 - 156
  • [39] SEMICONDUCTOR RADIATION DETECTORS - LARGE VOLUME GERMANIUM GAMMA-RAY SPECTROMETERS
    TRAMMELL, RC
    WAGNER, S
    NUCLEAR ENGINEERING INTERNATIONAL, 1972, 17 (192): : 389 - &
  • [40] MEV GAMMA-RAY DETECTION ALGORITHMS FOR STACKED SILICON DETECTORS
    MCMURRAY, RE
    HUBBARD, GS
    WERCINSKI, PF
    KELLER, RG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 882 - 889