Digital gamma-ray tracking algorithms in segmented germanium detectors

被引:10
|
作者
Pearson, CJ [1 ]
Dobón, JJV
Regan, PH
Sellin, PJ
Morton, E
Nolan, PJ
Boston, A
Descovich, M
Thornhill, J
Cresswell, J
Lazarus, I
Simpson, J
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[2] Univ Liverpool, Dept Phys, Liverpool L69 3BX, Merseyside, England
[3] SERC, Daresbury Lab, CCLRC, Warrington WA4 4AD, Cheshire, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1109/TNS.2002.1039639
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A gamma-ray tracking algorithm has been. implemented and tested, using simulated data, for gamma rays with energies between 0.1 and 2 MeV, and its performance evaluated for a 90-mm-long, 60-mm-diameter, cylindrical, 36 (6 x 6) segment detector. The performance of the algorithm in two areas was determined: Compton suppression and Doppler shift correction. It was found that for gamma rays of energies around 1 MeV, a ratio of photopeak counts to total counts of 2 : 3, could be obtained using the tracking algorithm, with only a 2% reduction in detection efficiency, compared to the untracked data. Approximately 80% of first interaction points could be correctly identified, enabling a good Doppler shift correction. A detector of the type simulated has recently been delivered, together with a compactPCI digital data acquisition system comprising 36 12-bit, 40-MHz flash ADCs, and 6 200-MHz DSPs. Some initial data has been recorded using this system, and the performance of the tracking algorithm on this real data is comparable to its performance on simulated data.
引用
收藏
页码:1209 / 1215
页数:7
相关论文
共 50 条
  • [21] Gamma-ray imaging with low fold segmented semiconductor detectors
    Mihailescu, L
    Gast, W
    Lieder, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 20 - 24
  • [22] FUZZY CLUSTERING ALGORITHM FOR GAMMA RAY TRACKING IN SEGMENTED DETECTORS
    Suliman, G.
    Bucurescu, D.
    ROMANIAN REPORTS IN PHYSICS, 2010, 62 (01) : 27 - 36
  • [23] NOTE ON LITHIUM-DRIFTED GERMANIUM GAMMA-RAY DETECTORS
    RAESIDE, DE
    AMERICAN JOURNAL OF PHYSICS, 1972, 40 (09) : 1343 - &
  • [24] Germanium (Compton) focal plane detectors for gamma-ray lenses
    Wunderer, Cornelia B.
    Weidenspointner, Georg
    Zoglauer, Andreas
    Ballmoos, Peter v.
    Barriere, Nicolas
    Boggs, Steven E.
    Halloin, Hubert
    Knodlseder, Jurgen
    Lund, Niels
    SPACE TELESCOPES AND INSTRUMENTATION II: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2006, 6266
  • [25] GAMMA-RAY DETECTORS BASED ON I-CONDUCTIVITY GERMANIUM
    VAVILOV, VS
    UKHRIN, Y
    CHUKICHE.MV
    GONCHARO.LA
    PAVLOVA, TI
    ATOMNAYA ENERGIYA, 1972, 32 (04): : 335 - &
  • [26] GAMMA-RAY DETECTORS MADE FROM HIGH PURITY GERMANIUM
    BAERTSCH, RD
    HALL, RN
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (03) : 235 - &
  • [27] RADIOACTIVE STANDARDS FOR CALIBRATION OF GERMANIUM DETECTORS FOR GAMMA-RAY SPECTROMETRY
    DEBERTIN, K
    SCHOTZIG, U
    WALZ, KF
    WEISS, HM
    PTB-MITTEILUNGEN, 1977, 87 (01): : 22 - 26
  • [28] ANALYTICAL APPROXIMATION OF THE GAMMA-RAY SPECTRA FROM GERMANIUM DETECTORS
    NAJAFI, SI
    KIKINDAI, T
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1982, 68 (1-2): : 127 - 134
  • [29] TOTAL EFFICIENCY OF GAMMA-RAY DETECTION BY GERMANIUM SEMICONDUCTOR DETECTORS
    GRAUDYNYA, LY
    PELEKIS, LL
    KALNYN, YRH
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1971, 9 (02): : 341 - +
  • [30] ISOTOPICALLY ENRICHED GERMANIUM DETECTORS FOR ASTROPHYSICAL GAMMA-RAY SPECTROSCOPY
    GEHRELS, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (02): : 505 - 516