Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinical trial

被引:62
|
作者
Adriaenssens, Tom [1 ,2 ]
Dens, Jo [3 ]
Ughi, Giovanni [1 ,2 ]
Bennett, Johan [1 ,2 ]
Dubois, Christophe [1 ,2 ]
Sinnaeve, Peter [1 ,2 ]
Wiyono, Stefanus [1 ,2 ]
Coosemans, Mark [1 ,2 ]
Belmans, Ann [1 ,2 ]
D'hooge, Jan [1 ,2 ]
Vrolix, Mathias [3 ]
Desmet, Walter [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Univ Hosp Leuven, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[3] ZOL Hosp Genk, Genk, Belgium
关键词
drug-eluting balloon; drug-eluting stent; in-stent restenosis; optical coherence tomography; percutaneous coronary intervention; stent coverage; BARE-METAL STENTS; COATED BALLOON; FOLLOW-UP; VASCULAR BRACHYTHERAPY; MYOCARDIAL-INFARCTION; NEOINTIMAL COVERAGE; ANGIOPLASTY; NEOATHEROSCLEROSIS; ANGIOGRAPHY; PREVENTION;
D O I
10.4244/EIJV10I4A77
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Little is known about the respective healing responses and clinical efficacy and safety of drug-eluting balloons (DEB) and the second generation of drug-eluting stents (DES) when used to treat in-stent restenosis (ISR). In this study, we set out to compare prospectively the healing characteristics, as assessed by optical coherence tomography (OCT), of DEB versus DES after treatment of ISR in bare metal stents (BMS). Methods and results: Fifty patients with BMS ISR were randomised to treatment with a paclitaxel-eluting balloon vs. an everolimus-eluting stent (EES). The primary endpoint was the percentage of uncovered struts, assessed with OCT at nine months, as a marker of vessel wall healing. A mean of 366 +/- 135 and 636 +/- 184 struts were analysed per patient in the DEB and EES groups, respectively. The percentage of uncovered struts per patient was significantly lower with DEB vs. EES (1.4% vs. 3.1%, p=0.025). Mean neointimal hyperplasia area was 2.4 +/- 1.08 mm(2) in DEB vs. 1.92 +/- 0.67 mm(2) in EES (p=0.1806), while the percentage of malapposed struts per patient was very low in both groups (0.2% vs. 0.3%, p=0.699). At nine months, angiographic in-stent MLD (minimum lumen diameter) was lower (2.13 vs. 2.54 mm, p=0.006), while diameter stenosis (26.4 vs. 11.4%, p=0.002), and LLL (0.28 vs. 0.07 mm, p=0.1) were higher after DEB compared to EES. During one-year follow-up, we did not observe differences in the rates of death, TLR (target lesion revascularisation) or stent thrombosis. Conclusions: DEB appears to be associated with better healing characteristics, as assessed by stent strut coverage with OCT, but tended to be slightly less effective compared to EES. These findings give support to the use of either DEB or EES as valuable treatment options for ISR.
引用
收藏
页码:439 / 448
页数:10
相关论文
共 50 条
  • [41] COMPARISON OF EFFICACY AND SAFETY BETWEEN SIROLIMUS, PACLITAXEL, EVEROLIMUS-ELUTING STENT AND SEQUENT™ PLEASE, A DRUG-ELUTING BALLOON ON THE OUTCOME OF PATIENTS WITH DIFFUSE IN-STENT RESTENOSIS AFTER BARE METAL STENT IMPLANTATION
    Nakamura, Sunao
    Ogawa, Hisao
    Bae, Jang-Ho
    Cahyadi, Yeo H.
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1638 - E1638
  • [42] COMPARISON OF EFFICACY AND SAFETY BETWEEN SIROLIMUS, PACLITAXEL, EVEROLIMUS-ELUTING STENT AND SEQUENT™ PLEASE, A DRUG-ELUTING BALLOON ON THE OUTCOME OF PATIENTS WITH DIFFUSE IN-STENT RESTENOSIS AFTER BARE METAL STENT IMPLANTATION
    Nakamura, Sunao
    Ogawa, Hisao
    Yeo, Hans
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1644 - E1644
  • [43] Comparison of Efficacy and Safety between Sirolimus, Paclitaxel, Everolimus-Eluting Stent and SeQuent™ Please, a Drug-Eluting Balloon on the Outcome of Patients with Diffuse In-Stent Restenosis after Bare Metal Stent Implantation
    Nakamura, Sunao
    Ogawa, Hisao
    Bae, Jang-Ho
    Cahyadi, Yeo H.
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    CIRCULATION, 2010, 122 (21)
  • [44] In-Stent Restenosis with "Inflammatory" Neointima Following Everolimus-Eluting Stent Implantation In Vivo Optical Coherence Tomography and Histopathological Assessment
    Tsuji, Yumika
    Koide, Masahiro
    Katsura, Kanade
    Fujita, Hiroshi
    Ishibashi-Ueda, Hatsue
    Otsuka, Fumiyuki
    INTERNATIONAL HEART JOURNAL, 2018, 59 (05) : 1142 - 1145
  • [45] Comparison of Efficacy and Safety between Sirolimus, Paclitaxel, Everolimus-Eluting Stent and SeQuent™ Please, a Drug-Eluting Balloon on the Outcome of Patients with Diffuse In-Stent Restenosis after Bare Metal Stent Implantation
    Nakamura, Sunao
    Ogawa, Hisao
    Bae, Jang-Ho
    Cahyadi, Yeo
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B22 - B22
  • [46] Comparison of paclitaxel-eluting vs. everolimus-eluting stents implanted simultaneously in different lesions of the same coronary artery: 12-month follow-up with optical coherence tomography
    de la Torre Hernandez, Jose M.
    Lee, Dae-Hyun
    Garcia-Camarero, Tamara
    Sainz Laso, Fermin
    Zueco, Javier
    EUROINTERVENTION, 2013, 9 (08) : 952 - 958
  • [47] A prospective randomized trial using optical coherence tomography to compare the Xience V everolimus-eluting stent with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial)
    Poerner, T. C.
    Otto, S.
    Janiak, F.
    Gassdorf, J.
    Nitsche, K.
    Jung, C.
    Goebel, B.
    Figulla, H. R.
    EUROPEAN HEART JOURNAL, 2012, 33 : 520 - 520
  • [48] Use of intravascular ultrasound vs. optical coherence tomography for mechanism and patterns of in-stent restenosis among bare metal stents and drug eluting stents
    Akhtar, Muzina
    Liu, Wei
    JOURNAL OF THORACIC DISEASE, 2016, 8 (01) : E104 - E108
  • [49] Difference of Tissue Characteristics in In-stent Re-restenosis Lesions: a Comparison Between Paclitaxel-eluting Balloon Dilatation and Plain Old Balloon Angioplasty for In-stent Restenosis Lesions After Drug-eluting Stent Implantation
    Tada, Takeshi
    Kadota, Kazushige
    Kubo, Shunsuke
    Ozaki, Masatomo
    Yoshino, Misturu
    Miyake, Koshi
    Eguchi, Haruki
    Ohashi, Noriyuki
    Hayakawa, Yuki
    Saito, Naoki
    Otsuru, Suguru
    Hasegawa, Daiji
    Shigemoto, Yoshikazu
    Habara, Seiji
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Oka, Naoki
    Kato, Harumi
    Yamamoto, Hiroyuki
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    CIRCULATION, 2011, 124 (21)
  • [50] In-stent restenosis in a polytetrafluoroethylene covered stent combined with drug eluting stents: potential pathogenesis revealed by optical coherence tomography
    Yang, Qing
    Liu, Wei
    Fang, Fang
    Yu, Cheuk-Man
    Zhou, Yu-Jie
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 198 : 42 - 44