Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinical trial

被引:62
|
作者
Adriaenssens, Tom [1 ,2 ]
Dens, Jo [3 ]
Ughi, Giovanni [1 ,2 ]
Bennett, Johan [1 ,2 ]
Dubois, Christophe [1 ,2 ]
Sinnaeve, Peter [1 ,2 ]
Wiyono, Stefanus [1 ,2 ]
Coosemans, Mark [1 ,2 ]
Belmans, Ann [1 ,2 ]
D'hooge, Jan [1 ,2 ]
Vrolix, Mathias [3 ]
Desmet, Walter [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Univ Hosp Leuven, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[3] ZOL Hosp Genk, Genk, Belgium
关键词
drug-eluting balloon; drug-eluting stent; in-stent restenosis; optical coherence tomography; percutaneous coronary intervention; stent coverage; BARE-METAL STENTS; COATED BALLOON; FOLLOW-UP; VASCULAR BRACHYTHERAPY; MYOCARDIAL-INFARCTION; NEOINTIMAL COVERAGE; ANGIOPLASTY; NEOATHEROSCLEROSIS; ANGIOGRAPHY; PREVENTION;
D O I
10.4244/EIJV10I4A77
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Little is known about the respective healing responses and clinical efficacy and safety of drug-eluting balloons (DEB) and the second generation of drug-eluting stents (DES) when used to treat in-stent restenosis (ISR). In this study, we set out to compare prospectively the healing characteristics, as assessed by optical coherence tomography (OCT), of DEB versus DES after treatment of ISR in bare metal stents (BMS). Methods and results: Fifty patients with BMS ISR were randomised to treatment with a paclitaxel-eluting balloon vs. an everolimus-eluting stent (EES). The primary endpoint was the percentage of uncovered struts, assessed with OCT at nine months, as a marker of vessel wall healing. A mean of 366 +/- 135 and 636 +/- 184 struts were analysed per patient in the DEB and EES groups, respectively. The percentage of uncovered struts per patient was significantly lower with DEB vs. EES (1.4% vs. 3.1%, p=0.025). Mean neointimal hyperplasia area was 2.4 +/- 1.08 mm(2) in DEB vs. 1.92 +/- 0.67 mm(2) in EES (p=0.1806), while the percentage of malapposed struts per patient was very low in both groups (0.2% vs. 0.3%, p=0.699). At nine months, angiographic in-stent MLD (minimum lumen diameter) was lower (2.13 vs. 2.54 mm, p=0.006), while diameter stenosis (26.4 vs. 11.4%, p=0.002), and LLL (0.28 vs. 0.07 mm, p=0.1) were higher after DEB compared to EES. During one-year follow-up, we did not observe differences in the rates of death, TLR (target lesion revascularisation) or stent thrombosis. Conclusions: DEB appears to be associated with better healing characteristics, as assessed by stent strut coverage with OCT, but tended to be slightly less effective compared to EES. These findings give support to the use of either DEB or EES as valuable treatment options for ISR.
引用
收藏
页码:439 / 448
页数:10
相关论文
共 50 条
  • [31] PREDICTORS OF ANGIOGRAPHIC OUTCOMES FOLLOWING IN-STENT RESTENOSIS TREATMENT WITH PACLITAXEL-ELUTING BALLOONS AND SECOND-GENERATION DRUG-ELUTING STENTS
    Gravel, G. Marquis
    Gobeil, F.
    Noiseux, N.
    Stevens, L.
    Mansour, S.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S279 - S280
  • [32] Impact of Paclitaxel-Eluting Balloons Compared to Second-Generation Drug-Eluting Stents for of In-Stent Restenosis in a Primarily Acute Coronary Syndrome Population
    Marquis-Gravel, Guillaume
    Matteau, Alexis
    Potter, Brian J.
    Gobeil, Francois
    Noiseux, Nicolas
    Stevens, Louis-Mathieu
    Mansour, Samer
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2017, 109 (04) : 277 - 283
  • [33] Paclitaxel-coated balloons: a safe alternative to drug-eluting stents for coronary in-stent restenosis
    Lansky, Alexandra
    Grubman, Daniel
    Scheller, Bruno
    EUROPEAN HEART JOURNAL, 2020, 41 (38) : 3729 - 3731
  • [34] A Prospective Randomized Trial of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis of Drug-Eluting Stents: The RIBS IV Randomized Clinical Trial (vol 66, pg 23, 2015)
    Alfonso, F.
    Perez-Vizcayno, M. J.
    Cardenas, A.
    del Blanco, Garcia B.
    Garcia-Touchard, A.
    Lopez-Minguez, J. R.
    Benedicto, A.
    Masotti, M.
    Zueco, J.
    Iniguez, A.
    Velazquez, M.
    Moreno, R.
    Mainar, V
    Dominguez, A.
    Pomar, F.
    Melgares, R.
    Rivero, F.
    Jimenez-Quevedo, P.
    Gonzalo, N.
    Fernandez, C.
    Macaya, C.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (12) : 1414 - 1414
  • [36] Neointimal Tissue Healing Patterns After Paclitaxel-Eluting Balloon Treatment of In-Stent Restenosis: Optical Coherence Tomography and Intravascular Ultrasound Insights
    Sandoval, Jorge
    Medina, Miguel
    Alfonso, Fernando
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (10): : E215 - E218
  • [37] PREDICTORS OF ANGIOGRAPHIC OUTCOMES FOLLOWING IN-STENT RESTENOSIS TREATMENT WITH PACLITAXEL-ELUTING BALLOONS AND SECOND-GENERATION DRUG-ELUTING STENTS.
    Gravel, Guillaume Marquis
    Gobeil, Francois
    Noiseux, Nicolas
    Stevens, Louis-Mathieu
    Mansour, Samer
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B138 - B139
  • [38] The effect of sex differences on neointimal characteristics of in-stent restenosis in drug-eluting stents: An optical coherence tomography study
    Yuan, Xiaohang
    Jiang, Mengting
    Feng, Huanhuan
    Han, Yan
    Zhang, Xi
    Chen, Yundai
    Gao, Lei
    HELIYON, 2023, 9 (08)
  • [39] 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents
    Alfonso, Fernando
    Jose Perez-Vizcayno, Maria
    Cuesta, Javier
    Garcia del Blanco, Bruno
    Garcia-Touchard, Arturo
    Ramon Lopez-Minguez, Jose
    Masotti, Monica
    Zueco, Javier
    Cequier, Angel
    Velazquez, Maite
    Moreno, Raul
    Mainar, Vicente
    Dominguez, Antonio
    Moris, Cesar
    Molina, Eduardo
    Rivero, Fernando
    Jimenez-Quevedo, Pilar
    Gonzalo, Nieves
    Fernandez-Perez, Cristina
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (10) : 981 - 991
  • [40] Impact of Optical Coherence Tomography Tissue Appearance and Properties for Restenosis of Drug-Eluting Stents on Recurrent In-Stent Restenosis Following Balloon Angioplasty
    Tahara, Satoko
    Fujino, Yusuke
    Nakamura, Shotaro
    Hozawa, Kouji
    Kurita, Naoyuku
    Ohta, Kenichi
    Tsukiji, Miwako
    Naganuma, Toru
    Watanabe, Yuzo
    Tanaka, Kentaro
    Mitomo, Satoru
    Kawamoto, Hirosada
    Nakamura, Sunao
    CIRCULATION, 2011, 124 (21)