Joint solution for PET image segmentation, denoising, and partial volume correction

被引:30
|
作者
Xu, Ziyue [1 ]
Gao, Mingchen [1 ]
Papadakis, Georgios Z. [1 ]
Luna, Brian [2 ]
Jain, Sanjay [3 ]
Mollura, Daniel J. [1 ]
Bagci, Ulas [4 ]
机构
[1] NIH, CIDI, Radiol & Imaging Sci Dept, Bethesda, MD 20892 USA
[2] Univ Calif Irvine, Irvine, CA USA
[3] Johns Hopkins Univ, Sch Med, Baltimore, MD USA
[4] Univ Cent Florida, Orlando, FL 32816 USA
关键词
Denoising; Affinity propagation; Partial volume correction; Segmentation; Regional means denoising; POSITRON-EMISSION-TOMOGRAPHY; WHOLE-BODY PET; BRAIN FDG-PET; ITERATIVE DECONVOLUTION; GAUSSIAN NOISE; RECONSTRUCTION; QUANTIFICATION; ALGORITHM; REGISTRATION; DELINEATION;
D O I
10.1016/j.media.2018.03.007
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Segmentation, denoising, and partial volume correction (PVC) are three major processes in the quantification of uptake regions in post-reconstruction PET images. These problems are conventionally addressed by independent steps. In this study, we hypothesize that these three processes are dependent; therefore, jointly solving them can provide optimal support for quantification of the PET images. To achieve this, we utilize interactions among these processes when designing solutions for each challenge. We also demonstrate that segmentation can help in denoising and PVC by locally constraining the smoothness and correction criteria. For denoising, we adapt generalized Anscombe transformation to Gaussianize the multiplicative noise followed by a new adaptive smoothing algorithm called regional mean denoising. For PVC, we propose a volume consistency-based iterative voxel-based correction algorithm in which denoised and delineated PET images guide the correction process during each iteration precisely. For PET image segmentation, we use affinity propagation (AP)-based iterative clustering method that helps the integration of PVC and denoising algorithms into the delineation process. Qualitative and quantitative results, obtained from phantoms, clinical, and pre-clinical data, show that the proposed framework provides an improved and joint solution for segmentation, denoising, and partial volume correction. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:229 / 243
页数:15
相关论文
共 50 条
  • [41] Partial volume correction strategies for quantitative FDG PET in oncology
    Hoetjes, Nikie J.
    van Velden, Floris H. P.
    Hoekstra, Otto S.
    Hoekstra, Corneline J.
    Krak, Nanda C.
    Lammertsma, Adriaan A.
    Boellaard, Ronald
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) : 1679 - 1687
  • [42] Partial volume correction strategies for quantitative FDG PET in oncology
    Nikie J. Hoetjes
    Floris H. P. van Velden
    Otto S. Hoekstra
    Corneline J. Hoekstra
    Nanda C. Krak
    Adriaan A. Lammertsma
    Ronald Boellaard
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 1679 - 1687
  • [43] A recovery coefficient method for partial volume correction of PET images
    Srinivas, Shyam M.
    Dhurairaj, Thiruvenkatasamy
    Basu, Sandip
    Bural, Gonca
    Surti, Suleman
    Alavi, Abass
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (04) : 341 - 348
  • [44] Regional deconvolution method for partial volume correction in brain PET
    Rusinek, H
    Tsuia, WH
    de Leon, MJ
    MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2001, 4321 : 409 - 418
  • [45] Correction of partial volume effects for PET imaging: a comparison study
    Kops, ER
    Reilhac, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4125 - 4126
  • [46] A simple method for partial volume effect correction in PET images
    Department of Nuclear Medicine, General Hospital of PLA, Beijing 100853, China
    不详
    Hedianzixue Yu Tance Jishue, 2007, 6 (1231-1238): : 1231 - 1238
  • [47] Partial volume correction of lung nodules using PET/CT
    Bradley, W.
    Wendt, R.
    Pan, T.
    Erasmus, J.
    White, R.
    Mawlawi, O.
    MEDICAL PHYSICS, 2007, 34 (06) : 2553 - 2553
  • [48] Correction for partial volume effect in PET blood flow images
    Gage, HD
    Fahey, FH
    Santago, P
    Harkness, BA
    Keyes, JW
    MEDICAL IMAGING 1996: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1996, 2709 : 244 - 253
  • [49] Partial volume correction strategies for quantitative FDG PET in oncology
    Hoetjes, Nikie
    Lammertsma, Adriaan
    Hoekstra, Otto
    Hoekstra, Corneline
    Krak, Nanda
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [50] Importance of partial-volume correction in brain PET studies
    Fazio, F
    Perani, D
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (11) : 1849 - 1850