Improving wedged field dose distributions

被引:10
|
作者
Keall, P
Zavgorodni, S
Schmidt, L
Haskard, D
机构
[1] QUEENSLAND UNIV TECHNOL,SCH PHYS,BRISBANE,QLD,AUSTRALIA
[2] ROYAL ADELAIDE HOSP,DEPT MED PHYS,ADELAIDE,SA 5000,AUSTRALIA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 11期
关键词
D O I
10.1088/0031-9155/42/11/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dose profiles produced by wedge filters in the non-wedged direction can exhibit a 7% or greater dose reduction at the outer ends of the field compared with open field profiles. However, many planning systems use open field profiles to model wedged dose distributions. In the present work, wedges have been modified to reproduce open field profile shapes. This modification involved removing varying thicknesses of the wedge using a simple milling machine. The wedge thickness was calculated using the assumption that dose is proportional to primary collision kerma. The discrepancies in dose between wedged field and open field profile shapes of up to 7% were reduced to less than 3% with the modifications, even for varying depths and off-axis distances. The necessary measurements are simple to perform, and hence this technique could be applied to improve wedged field dose distributions in other radiotherapy departments.
引用
收藏
页码:2183 / 2192
页数:10
相关论文
共 50 条
  • [1] ERRORS IN WEDGED FIELD ISODOSE DISTRIBUTIONS
    AMOLS, HI
    LAGUEUX, B
    MEDICAL PHYSICS, 1986, 13 (02) : 270 - 270
  • [2] Measured vs. calculated off-axis wedged dose distributions
    Sethi, A
    Leybovich, L
    Dogan, N
    Glasgow, G
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2502 - 2505
  • [3] SCATTER DOSE FOR WEDGED FIELDS
    BROWN, LH
    SIDDON, RL
    BJARNGARD, BE
    PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (10): : 1321 - 1326
  • [4] Improving jet distributions with effective field theory
    Bauer, Christian W.
    Schwartz, Matthew D.
    PHYSICAL REVIEW LETTERS, 2006, 97 (14)
  • [5] DOSE DISTRIBUTIONS IF FIELD IS LARGER THAN PATIENT
    FAW, FL
    GLENN, DW
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 675 - &
  • [6] ANALYTICAL CALCULATIONS OF SCATTERED DOSE FOR WEDGED FIELDS
    BROWN, LH
    SVENSSON, GK
    MEDICAL PHYSICS, 1981, 8 (04) : 577 - 577
  • [7] Characterization of wedge factors and dose distributions in radiotherapy with symmetric and asymmetric physical wedged beams of 6 MV photon beam
    Zabihzadeh M.
    Fadaei M.
    Hoseini S.M.
    Arvandi S.
    Tahmasbi M.
    Iranian Journal of Medical Physics, 2020, 17 (03) : 213 - 219
  • [8] CONTROL OF PROTON DOSE DISTRIBUTIONS FOR LARGE FIELD THERAPY
    SCHNEIDER, RJ
    KOEHLER, AM
    SISTERSON, JM
    SCHMIDT, RA
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 156 - 156
  • [9] DOSE DISTRIBUTIONS OF PENDULUM FIELDS IN THE FIELD BORDER PLANE
    SCHRADER, R
    STRAHLENTHERAPIE UND ONKOLOGIE, 1986, 162 (12): : 764 - 767
  • [10] Improving the mean field approximation via the use of mixture distributions
    Jaakkola, TS
    Jordan, MI
    LEARNING IN GRAPHICAL MODELS, 1998, 89 : 163 - 173