High-intensity transient signals due to prosthetic valve obstruction: Diagnostic and therapeutic implications

被引:5
|
作者
Hiratsuka, R [1 ]
Fukunaga, S [1 ]
Tayama, E [1 ]
Takagi, K [1 ]
Arinaga, K [1 ]
Shojima, T [1 ]
Teshima, H [1 ]
Aoyagi, S [1 ]
机构
[1] Kurume Univ, Sch Med, Dept Surg, Kurume, Fukuoka 8300011, Japan
来源
ANNALS OF THORACIC SURGERY | 2004年 / 77卷 / 05期
关键词
D O I
10.1016/j.athoracsur.2003.10.062
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. High-intensity transient signals (HITS) can be detected by transcranial Doppler ultrasonography (TCD) in patients carrying a mechanical prosthetic valve. The HITS counts and a frequency analysis were evaluated in patients with prosthetic valve obstruction in the aortic position. Methods. Simultaneous echocardiographic, cineradiographic, and TCD evaluations for a St. Jude Medical valve were performed. in 108 patients. All patients were asymptomatic and had no significant stenosis of the carotid artery. The HITS were identified according to criteria established by consensus of the International Cerebral Hemodynamics Symposium. Results. The HITS counts in 69 patients with normal prosthetic valve function were 2.2 +/- 4.4, and the counts in 39 patients with prosthetic valve obstruction (group D) were 8.3 +/- 10.8. This difference was significant (p = 0.0002). In 2 patients of group D who had a greater rate of less than 400 Hz HITS, which were produced by solid microemboli, thrombolysis resulted in a mitigation of restricted leaflet movement equal to or greater than 10degrees. The total number of HITS decreased and the rate of less than 400 Hz HITS also markedly decreased after thrombolysis in these 2 patients. On the other hand, 4 patients who obtained no improvement of leaflet movement by thrombolysis had lower rates of less than 400 Hz HITS than did the 2 patients. Conclusions. These results suggest that measurement of HITS counts is useful for detection of prosthetic valve obstruction, and that a frequency analysis of HITS may be valuable to clarify the cause of the obstructed prosthetic valves.
引用
收藏
页码:1615 / 1621
页数:7
相关论文
共 50 条
  • [31] Correlation of platelet inhibition and cerebral thromboembolic events, as expressed with number of high-intensity transient signals,during Transcatheter Aortic valve Implantation
    Katsianos, E.
    Vavuranakis, M.
    Kalantzis, C. K.
    Voudris, V. V.
    Kosmas, E. K.
    Iakovou, I. I.
    Kalogeras, K. K.
    Siasos, G. S.
    Bei, E. B.
    Katsarou, O.
    Aznaouridis, K.
    Toutouzas, K. T.
    Moldovan, C. M.
    Tousoulis, D. T.
    Vavuranakis, E. V.
    EUROPEAN HEART JOURNAL, 2020, 41 : 2609 - 2609
  • [32] Hemolysis, high-intensity transient signals (HITS) and hemodynamic results after aortic valve replacement with the Medtronic Hall Easy-Fit™ heart valve prosthesis
    Warnecke, RH
    Laas, J
    Hecker, H
    Perthel, M
    Alken, A
    JOURNAL OF HEART VALVE DISEASE, 2006, 15 (02): : 174 - 179
  • [33] Thrombotic Obstruction of a Mechanical Prosthetic Valve in Tricuspid Position: Therapeutic Considerations
    Manuel Caceres-Loriga, Fidel
    Santos-Gracia, Jose
    Perez-Lopez, Horacio
    TEXAS HEART INSTITUTE JOURNAL, 2009, 36 (05): : 505 - 505
  • [34] Multiple High-Intensity Transient Signals in a Polycythemia Rubra Vera Patient with Hemorrhagic Infarction: A Case
    Marie Beltran, Jeanie Allen
    Jose, Navarro
    Kristoffer Batino, Laurence
    Timothy Cinco, Mark
    CEREBROVASCULAR DISEASES, 2023, 52 : 275 - 275
  • [35] Effectiveness of Platelet Inhibition on Reducing High-Intensity Transient Signals to Cerebral Circulation During Tavi
    Kalantzis, Charalampos
    Vavouranakis, Michael
    Kariori, Maria
    Voudris, Vasilios
    Toutouzas, Konstantinos
    Latsios, Georgios
    Kosmas, Elias
    Kalogeras, Konstantinos
    Moldovan, Carmen-Maria
    Bei, Evangelia
    Kolokathis, Angel-Michail
    Vrachatis, Dimitrios
    Siasos, Gerasimos
    Tousoulis, Dimitrios
    Vavuranakis, Manolis
    CIRCULATION, 2018, 138
  • [36] High-Intensity Transient Signals in the Outflow Graft and Thrombosis of a HeartWare Left Ventricular Assist Device
    Dimitrov, Kamen
    Riebandt, Julia
    Haberl, Thomas
    Wiedemann, Dominik
    Simon, Paul
    Laufer, Guenther
    Schima, Heinrich
    Zimpfer, Daniel
    ANNALS OF THORACIC SURGERY, 2016, 101 (03): : E83 - E85
  • [37] SPALL DUE TO SHORT HIGH-INTENSITY IMPULSES
    FROESCHNER, KE
    MAIDEN, DE
    CHAU, HH
    JOURNAL OF APPLIED PHYSICS, 1989, 65 (08) : 2964 - 2973
  • [38] Prosthetic Mitral Valve Obstruction with Left Atrial Appendage Thrombus: A Therapeutic Dilemma
    Ravi, Venkatesh
    Chandran, Aswathi
    Matar, Ralph
    Pulipati, Priyanjali
    Yadav, Neha
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)
  • [39] Native and prosthetic valve infective endocarditis complicated by rapidly progressive glomerulonephritis and its diagnostic challenges and therapeutic implications
    Getachew, Yitagesu
    Getahun, Zerubabel
    Wondafrash, Getachew
    Asmare, Zemenay
    Solela, Gashaw
    Aberra, Beka
    Daba, Merga
    CLINICAL CASE REPORTS, 2024, 12 (06):
  • [40] Relationship between exercise-induced heart rate increase and the formation of microbubbles and high-intensity transient signals in mechanical heart valve implanted patients
    Sunbul, Aysegul
    Kirbas, Ahmet
    Tanrikulu, Nursen
    Sengul, Cihan
    Dagdeviren, Bahadir
    Isik, Omer
    ARCHIVES OF MEDICAL SCIENCE, 2014, 10 (04) : 701 - 705