High-intensity transient signals due to prosthetic valve obstruction: Diagnostic and therapeutic implications

被引:5
|
作者
Hiratsuka, R [1 ]
Fukunaga, S [1 ]
Tayama, E [1 ]
Takagi, K [1 ]
Arinaga, K [1 ]
Shojima, T [1 ]
Teshima, H [1 ]
Aoyagi, S [1 ]
机构
[1] Kurume Univ, Sch Med, Dept Surg, Kurume, Fukuoka 8300011, Japan
来源
ANNALS OF THORACIC SURGERY | 2004年 / 77卷 / 05期
关键词
D O I
10.1016/j.athoracsur.2003.10.062
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. High-intensity transient signals (HITS) can be detected by transcranial Doppler ultrasonography (TCD) in patients carrying a mechanical prosthetic valve. The HITS counts and a frequency analysis were evaluated in patients with prosthetic valve obstruction in the aortic position. Methods. Simultaneous echocardiographic, cineradiographic, and TCD evaluations for a St. Jude Medical valve were performed. in 108 patients. All patients were asymptomatic and had no significant stenosis of the carotid artery. The HITS were identified according to criteria established by consensus of the International Cerebral Hemodynamics Symposium. Results. The HITS counts in 69 patients with normal prosthetic valve function were 2.2 +/- 4.4, and the counts in 39 patients with prosthetic valve obstruction (group D) were 8.3 +/- 10.8. This difference was significant (p = 0.0002). In 2 patients of group D who had a greater rate of less than 400 Hz HITS, which were produced by solid microemboli, thrombolysis resulted in a mitigation of restricted leaflet movement equal to or greater than 10degrees. The total number of HITS decreased and the rate of less than 400 Hz HITS also markedly decreased after thrombolysis in these 2 patients. On the other hand, 4 patients who obtained no improvement of leaflet movement by thrombolysis had lower rates of less than 400 Hz HITS than did the 2 patients. Conclusions. These results suggest that measurement of HITS counts is useful for detection of prosthetic valve obstruction, and that a frequency analysis of HITS may be valuable to clarify the cause of the obstructed prosthetic valves.
引用
收藏
页码:1615 / 1621
页数:7
相关论文
共 50 条
  • [21] HIGH-INTENSITY TRANSIENT TRANSCRANIAL DOPPLER SIGNALS ARE ASSOCIATED WITH CEREBRAL ISCHEMIC SYMPTOMS
    BABIKIAN, VL
    HYDE, C
    POCHAY, V
    ANNALS OF NEUROLOGY, 1994, 36 (02) : 305 - 305
  • [22] Transcranial Doppler high-intensity transient signals during cardiac catheterization and angiography
    Morimoto, K
    Matsumura, Y
    Ishikawa, M
    Mitani, T
    Doi, T
    Fukui, T
    Osaki, Y
    Kitaoka, H
    Seo, H
    Chikamori, T
    Doi, Y
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 339A - 339A
  • [23] INTERPRETATION OF HIGH-INTENSITY TRANSIENT SIGNALS (HITS) DURING INTRACRANIAL DOPPLER SONOGRAPHY
    SLIWKA, U
    DIEHL, RR
    NOTH, J
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1995, 120 (48) : 1667 - 1670
  • [24] Impact of high intensity transient signals on the choice of mechanical aortic valve substitutes
    Laas, J
    Kseibi, S
    Perthel, M
    Klingbeil, A
    El-Ayoubi, L
    Alken, A
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (01) : 93 - 96
  • [25] Effectiveness of atrial fibrillation on high-intensity transient signals to cerebral circulation during TAVI
    Kalantzis, C.
    Vavuranakis, M. A.
    Voudris, V.
    Kosmas, E.
    Kalogeras, K.
    Bei, E.
    Katsianos, E.
    Siasos, G.
    Tousoulis, D.
    Tsioufis, C.
    Vavuranakis, M.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1630 - 1630
  • [26] High-intensity transient signals (HITS) as a parameter for optimum orientation of mechanical aortic valves
    Kleine, P
    Perthel, M
    Hasenkam, JM
    Nygaard, H
    Hansen, SB
    Laas, J
    THORACIC AND CARDIOVASCULAR SURGEON, 2000, 48 (06): : 360 - 363
  • [27] Intraoperative cerebral high-intensity transient signals and postoperative cognitive function: a systematic review
    Whitaker, Donald
    Motallebzadeh, Reza
    AMERICAN JOURNAL OF SURGERY, 2009, 198 (02): : 295 - 297
  • [28] Intraoperative cerebral high-intensity transient signals and postoperative cognitive function: a systematic review
    Martin, Kristin K.
    Wigginton, Jeremy B.
    Babikian, Viken L.
    Pochay, Val E.
    Crittenden, Michael D.
    Rudolph, James L.
    AMERICAN JOURNAL OF SURGERY, 2009, 197 (01): : 55 - 63
  • [29] The narrow band hypothesis: An interesting approach for high-intensity transient signals (hits) detection
    Roy, E
    Abraham, P
    Montresor, S
    Baudry, M
    Saumet, JL
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03): : 375 - 382
  • [30] Detection of high-intensity transient signals by Doppler ultrasound during percutaneous coronary interventions
    Bahrmann, P
    Werner, GS
    Wagner, M
    Ferrari, M
    Hopfe, J
    Voss, A
    Figulla, HR
    EUROPEAN HEART JOURNAL, 2004, 25 : 98 - 98