High-intensity transient signals due to prosthetic valve obstruction: Diagnostic and therapeutic implications

被引:5
|
作者
Hiratsuka, R [1 ]
Fukunaga, S [1 ]
Tayama, E [1 ]
Takagi, K [1 ]
Arinaga, K [1 ]
Shojima, T [1 ]
Teshima, H [1 ]
Aoyagi, S [1 ]
机构
[1] Kurume Univ, Sch Med, Dept Surg, Kurume, Fukuoka 8300011, Japan
来源
ANNALS OF THORACIC SURGERY | 2004年 / 77卷 / 05期
关键词
D O I
10.1016/j.athoracsur.2003.10.062
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. High-intensity transient signals (HITS) can be detected by transcranial Doppler ultrasonography (TCD) in patients carrying a mechanical prosthetic valve. The HITS counts and a frequency analysis were evaluated in patients with prosthetic valve obstruction in the aortic position. Methods. Simultaneous echocardiographic, cineradiographic, and TCD evaluations for a St. Jude Medical valve were performed. in 108 patients. All patients were asymptomatic and had no significant stenosis of the carotid artery. The HITS were identified according to criteria established by consensus of the International Cerebral Hemodynamics Symposium. Results. The HITS counts in 69 patients with normal prosthetic valve function were 2.2 +/- 4.4, and the counts in 39 patients with prosthetic valve obstruction (group D) were 8.3 +/- 10.8. This difference was significant (p = 0.0002). In 2 patients of group D who had a greater rate of less than 400 Hz HITS, which were produced by solid microemboli, thrombolysis resulted in a mitigation of restricted leaflet movement equal to or greater than 10degrees. The total number of HITS decreased and the rate of less than 400 Hz HITS also markedly decreased after thrombolysis in these 2 patients. On the other hand, 4 patients who obtained no improvement of leaflet movement by thrombolysis had lower rates of less than 400 Hz HITS than did the 2 patients. Conclusions. These results suggest that measurement of HITS counts is useful for detection of prosthetic valve obstruction, and that a frequency analysis of HITS may be valuable to clarify the cause of the obstructed prosthetic valves.
引用
收藏
页码:1615 / 1621
页数:7
相关论文
共 50 条
  • [2] Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients
    Milano, A
    D'Alfonso, A
    Codecasa, R
    De Carlo, M
    Nardi, C
    Orlandi, G
    Landucci, L
    Bortolotti, U
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (05): : 488 - 494
  • [3] Intracranial high-intensity transient signals after homograft or mechanical aortic valve replacement
    Lievense, AM
    Bakker, SLM
    Dippel, DWJ
    Taams, MA
    Koudstaal, PJ
    Bogers, AJJC
    JOURNAL OF CARDIOVASCULAR SURGERY, 1998, 39 (05): : 613 - 617
  • [4] High-intensity transient signals in patients with cerebral ischemia
    Daffertshofer, M
    Ries, S
    Schminke, U
    Hennerici, M
    STROKE, 1996, 27 (10) : 1844 - 1849
  • [5] Platelet aggregation and high-intensity transient signals (HITS) in a sheep model of mitral valve replacement
    Raco, L
    Belcher, PR
    Sim, I
    McGarrity, A
    Bernacca, GM
    Wheatley, DJ
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (05): : 476 - 480
  • [6] Clinical relevance of intracranial high intensity transient signals in patients following prosthetic aortic valve replacement
    Kofidis, T
    Fischer, S
    Leyh, R
    Mair, H
    Deckert, M
    Haberl, R
    Haverich, A
    Reichart, B
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (01) : 22 - 26
  • [7] Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients - Meeting discussion
    Shah, P
    Milano, A
    Kleine, P
    Hwang, N
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (05): : 494 - 494
  • [8] Cognitive dysfunction due to high intensity transient signals (HITS) following mechanical valve replacement
    Laas, J
    Daum, I
    Ueckermann, J
    Klingbell, A
    Perthel, M
    CIRCULATION, 2002, 106 (19) : 514 - 514
  • [9] HIGH-INTENSITY TRANSIENT SIGNALS AND CAROTID-ARTERY DISEASE
    RIES, S
    SCHMINKE, U
    DAFFERTSHOFER, M
    SCHINDLMAYR, C
    HENNERICI, M
    CEREBROVASCULAR DISEASES, 1995, 5 (02) : 124 - 127
  • [10] EXPERIMENTAL ASPECTS OF HIGH-INTENSITY TRANSIENT SIGNALS IN THE DETECTION OF EMBOLI
    MARKUS, HS
    TEGELER, CH
    JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (02) : 81 - 87