Inception of electrical tree from water-tree degradation

被引:0
|
作者
Suzuoki, Y. [1 ]
Saito, T. [1 ]
Komori, F. [2 ]
Uchida, K. [3 ]
机构
[1] Nagoya Univ, Nagoya, Aichi, Japan
[2] Toba Natl Coll Maritime Technol, Toba, Mie, Japan
[3] Chubu Elect Power Co Inc, Nagoya, Aichi, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to clarify the mechanism of electrical-tree inception and propagation from a water tree within polyethylene, we carried out simultaneous observation of partial discharge characteristics, electrical-tree inception and propagation and associated light emission on both samples with a wet water tree and a dried water tree. The ac electrical-tree inception voltage increased with increasing water-tree degradation in a sample with a wet water tree, which was attributed to field moderation. On the other hand, under impulse voltage application the increase in tree-inception voltage is much, higher than ac-tree-inception voltage, suggesting increase in the intrinsic breakdown strength in and/or near water-tree region. On the basis of these results, effects of structural change in water tree region on electrical tree inception were discussed by investigating effects of drying of water tree and ac prestressing.
引用
收藏
页码:111 / +
页数:2
相关论文
共 50 条
  • [31] New residual-charge measurement for water-tree deteriorated power cable
    Kon, H
    Wantanabe, K
    Miyajima, K
    Uchida, K
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 77 - 82
  • [32] Transformation Mechanism of Electrical Tree to Water Tree in XLPE Cables
    Huang, Ming
    Zhou, Kai
    Tao, Wenbiao
    Yang, Mingliang
    Yang, Di
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014, : 1491 - 1496
  • [33] Power frequency breakdown characteristics of water-tree retardant XLPE power cable
    Yan, Meng-Kun
    Luo, Jun-Hua
    Yang, Li-Ming
    Zheng, Chuan-Bao
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (10): : 2395 - 2400
  • [34] THRESHOLD VOLTAGE FOR ELECTRICAL TREE INCEPTION IN UNDERGROUND HV TRANSMISSION CABLES
    BAMJI, SS
    BULINSKI, AT
    CHEN, Y
    DENSLEY, RJ
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (02): : 402 - 404
  • [35] Fundamental study on water-tree degradation diagnosis for dry-cured and extruded three-layer (E-E Type) 6.6 kV XLPE cables with penetrated water tree
    Kurihara T.
    Sato T.
    Kabasawa Y.
    Nagashima T.
    IEEJ Transactions on Fundamentals and Materials, 2019, 139 (04) : 226 - 233
  • [36] The effect of semiconductive screens and XLPE insulation combinations on electrical tree inception
    Moody, SM
    Hampton, RN
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 106 - 109
  • [37] The effect of semiconductive screens and XLPE insulation combinations on electrical tree inception
    Moody, SM
    Hampton, RN
    CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 591 - 594
  • [38] Retardation of electrical tree propagation by resin degradation
    Weiers, T.
    Keller, D.
    Hutter, W.
    Stephan, C. E.
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2007, 17 (03): : 255 - 267
  • [39] Investigation of electrical tree propagation from water tree by utilizing partial discharge and optical observation
    Morita, M
    Wu, K
    Komori, F
    Suzuoki, Y
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 891 - 894
  • [40] Correlation between space charge distribution and water-tree location in aged XLPE cable
    Suzuki, K
    Tanaka, Y
    Takada, T
    Ohki, Y
    Takeya, C
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2001, 8 (01) : 78 - 81