New residual-charge measurement for water-tree deteriorated power cable

被引:0
|
作者
Kon, H [1 ]
Wantanabe, K [1 ]
Miyajima, K [1 ]
Uchida, K [1 ]
机构
[1] Fujikura LTd, Adv Technol Ctr Power T&D Syst, Futtu City, Chiba 2930011, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have been investigating the residual-charge measurement as a diagnostic method for water-tree deteriorated cross-linked polyethylene cables. The conventional method uses the amount of the residual charge as a diagnostic index, but it has a difficulty in estimating the degree of water-tree deterioration in a long line, because the amount of the residual charge depends on the length of the cable. The distribution of residual charges obtained by using the unproved method we proposed here could correlate to the water-tree distribution in insulation of the cable. In this method, the residual-charge component released by higher AC voltage application, which could correspond to longer water trees, is used as an index how degree the insulation is deteriorated by water trees. This index is independent of the length of the cable. Therefore, the method we have developed is effective to diagnose the degree of water-tree deterioration. We applied this method to the cable line in fields and confirmed its effectiveness.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 37 条
  • [2] Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable
    Ebinuma, Yasumitsu
    Masui, Noriaki
    [J]. TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2006, 7 (05) : 224 - 229
  • [3] Correlation between space charge distribution and water-tree location in aged XLPE cable
    Suzuki, K
    Tanaka, Y
    Takada, T
    Ohki, Y
    Takeya, C
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2001, 8 (01) : 78 - 81
  • [4] Investigation on dynamic characteristics of water-tree discharge in underground cable
    Yang Qi
    Yang Fan
    Gao Bing
    Jadoon, Ammad
    Huang Xin
    Zou Lekai
    Wang Shaohua
    Cao Junping
    [J]. PROCEEDINGS OF THE 2019 14TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2019), 2019, : 832 - 836
  • [5] Current Integrated Technique for Insulation Diagnosis of Water-tree Degraded Cable
    Wang, Weiwang
    Sonoda, Keita
    Yoshida, Syugo
    Takada, Tatsuo
    Tanaka, Yasuhiro
    Kurihara, Takashi
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (01) : 94 - 101
  • [6] Research on the properties of water-tree in PP/POE composites for cable insulation
    Ren, Guangzhen
    Wang, Zhao
    Li, Peng
    Chen, Kexin
    Tang, Zhenfu
    Xu, Man
    [J]. 2024 IEEE ELECTRICAL INSULATION CONFERENCE, EIC 2024, 2024, : 277 - 282
  • [7] Influence of AC Voltage Prestressing on AC Electrical-tree Inception of Deteriorated LDPE with Dried Water-tree
    Asai, D.
    Kurimoto, M.
    Komori, F.
    Kato, T.
    Funabashi, T.
    Suzuoki, Y.
    [J]. 2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 385 - 388
  • [8] Study on Charge Dynamics in Water-Tree XLPE Insulation for Deterioration Diagnosis
    Ra, Nhet
    Futami, Hiroyuki
    Kawashima, Tomohiro
    Murakami, Yoshinobu
    Hozumi, Naohiro
    Kurihara, Takashi
    Okamoto, Tatsuki
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 343 - 346
  • [9] Water Tree Deterioration Diagnosis for 10 kV XLPE cable based on Residual Charge Method
    Du, B. X.
    Huo, Z. X.
    Li, H. B.
    Gao, Y.
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 417 - 420
  • [10] High frequency characteristics of water-tree degraded XLPE insulation in power cables
    Mugala, Gavita
    Eriksson, Roland
    Pettersson, Per
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (05) : 1271 - 1277