Measuring Ventricular Width on Cranial Computed Tomography: Feasibility of Dose Reduction in a Custom-Made Adult Phantom

被引:6
|
作者
Daubner, D. [1 ]
Spieth, S. [2 ]
Cerhova, J. [1 ]
Linn, J. [1 ]
Kirchhof, K. [3 ]
机构
[1] Univ Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, Germany
[2] Univ Dresden, Carl Gustav Carus Med Sch, Dept Radiol, Dresden, Germany
[3] Hosp Chemnitz, Dept Diagnost & Intervent Radiol & Neuroradiol, Chemnitz, Germany
关键词
brain; radiation dose; CT-spiral; ventricular width; hydrocephalus; adults; NONENHANCED HEAD CT; IMAGE QUALITY; RADIATION; CHILDREN; LENS;
D O I
10.1055/s-0041-106072
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate feasible dose reduction to reliably measure ventricular width in adults with hydrocephalus in follow-up cranial computed tomography (CCT) using a custom-made phantom. Materials and Methods: A gelatine-filled adult calvarium with embedded central fibers of two carrots representing the lateral ventricles was used as a phantom. The phantom was scanned 11 times with two CT scanners (LightSpeed Ultra, GE and Somatom Sensation, Siemens), using tube currents of 380/400, 350, 300, 250, 200, 150 and 100 mA, and tube voltages of 140, 120, 100 and 80 kV. The width of the carrots was measured at four sites in consensus decision of two principle investigators blinded to the scan parameters. Values measured at 380/400 mA and 140 kV served as a reference for the width of the ventricles. Measurements received 1 point if they did not differ more than 0.5 mm from the reference values. A maximum score of 4 could be achieved. Results: The relationship between the correct width measurement of the carrots (lateral ventricles) and the radiation dose can be described by a quadratic regression function. Pixel noise increases and accuracy of measurements decreases with a lower radiation dose. Starting from a tube current of 380/400 mA and a tube voltage of 140 kV, the dose can be reduced by 76 % for LightSpeed Ultra and by 80 % for Somatom Sensation provided that a margin of error of 37.5 % (score = 2.5) for correct width measurement of the carrots is accepted. Conclusion: Lowering the radiation dose by up to 48 % for LightSpeed Ultra and by 52 % for Somatom Sensation, compared to the standard protocol (120 kV and 400 mA) still allowed reliable measurements of ventricular widths in this model.
引用
收藏
页码:73 / 81
页数:9
相关论文
共 48 条
  • [1] CRANIAL COMPUTED-TOMOGRAPHY AND ULTRASOUND IN NEONATES - A SUPERMARKET, MAIL-ORDER OR CUSTOM-MADE APPROACH
    HARWOODNASH, DC
    MARTIN, DJ
    FITZ, CR
    CHUANG, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (04) : 864 - 865
  • [2] Usage of Industrial Computed Tomography for Evaluation of Custom-Made Implants
    Hudak, Radovan
    Zivcak, Jozef
    Toth, Teodor
    Majernik, Jaroslav
    Lisy, Martin
    [J]. APPLICATIONS OF COMPUTATIONAL INTELLIGENCE IN BIOMEDICAL TECHNOLOGY, 2016, 606 : 29 - 45
  • [3] Evaluation of Custom-Made Implants Using Industrial Computed Tomography
    Radovan, Hudak
    Jozef, Zivcak
    Teodor, Toth
    Jaroslav, Majernik
    Martin, Lisy
    [J]. 2014 10TH INTERNATIONAL CONFERENCE ON DIGITAL TECHNOLOGIES (DT), 2014, : 82 - 86
  • [4] Feasibility of slice width reduction for spiral cranial computed tomography using iterative image reconstruction
    Haubenreisser, Holger
    Fink, Christian
    Nance, John W., Jr.
    Sedlmair, Martin
    Schmidt, Bernhard
    Schoenberg, Stefan O.
    Henzler, Thomas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (06) : 964 - 969
  • [5] Ultrasound Computed Tomography in Breast Imaging: First Clinical Results of a Custom-Made Scanner
    Hollenhorst, M.
    Hansen, C.
    Huettebraeuker, N.
    Schasse, A.
    Heuser, L.
    Ermert, H.
    Schulte-Altedorneburg, G.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2010, 31 (06): : 604 - 609
  • [6] Computed Tomography-Based Custom-Made Stem for Dysplastic Hips in Japanese Patients
    Kawate, Kenji
    Ohneda, Yutaka
    Ohmura, Tetsuji
    Yajima, Hiroshi
    Sugimoto, Kazuya
    Takakura, Yoshinori
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 65 - 70
  • [7] Characterization of Commercial and Custom-Made Printing Filament Materials for Computed Tomography Imaging of Radiological Phantoms
    Okkalidis, Filippos
    Chatzigeorgiou, Chrysoula
    Okkalidis, Nikiforos
    Dukov, Nikolay
    Milev, Minko
    Bliznakov, Zhivko
    Mettivier, Giovanni
    Russo, Paolo
    Bliznakova, Kristina
    [J]. TECHNOLOGIES, 2024, 12 (08)
  • [8] Feasibility study for distributed dose monitoring in ionizing radiation environments with standard and custom-made optical fibers
    Van Uffelen, M
    Berghmans, F
    Brichard, B
    Borgermans, P
    Decréton, M
    [J]. PHOTONICS FOR SPACE ENVIRONMENTS VIII, 2002, 4823 : 213 - 221
  • [9] Estimation of the Minimum Dose Required to Measure Ventricular Width in Follow-Up Cranial Computed Tomography (CCT) in Children with Hydrocephalus
    Kirchhof, K.
    Wohlgemuth, W. A.
    Berlis, A.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (12): : 1118 - 1124
  • [10] Production of custom-made bungs using computed tomography and rapid prototyping: a novel method to correct nasoseptal defects
    Key, S. J.
    Evans, P. L.
    Bocca, A.
    Whittet, H.
    Silvester, K. C.
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2008, 46 (06): : 507 - 508