Monte Carlo simulation of lung counting efficiency using a whole-body counter at a nuclear power plant

被引:0
|
作者
Dongming, L. [1 ,2 ,3 ]
Shuhai, J. [3 ]
Houwen, L. [4 ]
机构
[1] Shaanxi Normal Univ, Sch Phys & Informat Technol, Xian 710119, Peoples R China
[2] Xian Shiyou Univ, Sch Sci, 18 Second Dianzi Rd, Xian 710065, Peoples R China
[3] Xi An Jiao Tong Univ, 28 Xianning Rd West, Xian 710049, Peoples R China
[4] Third Qinshan Nucl Power Co Ltd, Haiyan 314300, Peoples R China
关键词
whole-body counter; Monte Carlo simulation; lung counting; counting efficiency;
D O I
10.1051/radiopro/2015030
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to routinely evaluate workers' internal exposure due to intake of radionuclides, a whole-body counter (WBC) at the Third Qinshan Nuclear Power Co.Ltd. (TQNPC) is used. Counting would typically occur immediately after a confirmed or suspected inhalation exposure. The counting geometry would differ as a result of the height of the individual being counted, which would result in over- or underestimated intake(s). In this study, Monte Carlo simulation was applied to evaluate the counting efficiency when performing a lung count using the WBC at the TQNPC. In order to validate the simulated efficiencies for lung counting, the WBC was benchmarked for various lung positions using a Cs-137 source. The results show that the simulated efficiencies are fairly consistent with the measured ones for Cs-137, with a relative error of 0.289%. For a lung organ simulation, the discrepancy between the calibration phantom and the Chinese reference adult person (170 cm) was within 6% for peak energies ranging from 59.5 keV to 2000 keV. The relative errors vary from 4.63% to 8.41% depending on the person's height and photon energy. Therefore, the simulation technique is effective and practical for lung counting, which is difficult to calibrate using a physical phantom.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 50 条
  • [1] EVALUATION OF COUNTING EFFICIENCIES OF A WHOLE-BODY COUNTER USING MONTE CARLO SIMULATION WITH VOXEL PHANTOMS
    Takahashi, Masa
    Kinase, Sakae
    Kramer, Richard
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 407 - 410
  • [2] MONTE CARLO SIMULATION OF A WHOLE-BODY COUNTER USING IGOR PHANTOMS
    Bochud, Francois O.
    Laedermann, Jean-Pascal
    Baechler, Sebastien
    Bailat, Claude J.
    Boschung, Markus
    Aroua, Abbas
    Mayer, Sabine
    RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 280 - 288
  • [3] Monte Carlo simulation of the movement and detection efficiency of a whole-body counting system using a BOMAB phantom
    Bento, Joana
    Barros, Silvia
    Teles, Pedro
    Neves, Maria
    Goncalves, Isabel
    Corisco, Jose
    Vaz, Pedro
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (04) : 403 - 413
  • [4] A calibration method for whole-body counters, using Monte Carlo simulation
    Ishikawa, T
    Matsumoto, M
    Uchiyama, M
    RADIATION PROTECTION DOSIMETRY, 1996, 64 (04) : 283 - 288
  • [5] Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations
    Park, MinSeok
    Kim, Han Sung
    Yoo, Jaeryong
    Kim, Chan Hyeong
    Jang, Won Il
    Park, Sunhoo
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (12) : 4122 - 4129
  • [6] Evaluation of counting efficiency of a whole-body counter using the EGS4 code
    Kinase, S
    Yoshizawa, M
    Noguchi, H
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2000, 37 (12) : 1103 - 1107
  • [7] Application of voxel phantoms and Monte Carlo method to whole-body counter calibration
    Kinase, S.
    Takagi, S.
    Noguchi, H.
    Saito, K.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 189 - 193
  • [8] Improvement to whole-body counting procedures at nuclear power plants
    Kong, Tae Young
    Kim, Hee Geun
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (02) : 89 - 96
  • [9] Calibration of a whole body counter using Monte Carlo methods
    Breustedt, Bastian
    Schieck, Hans Paetz Gen
    Schicha, Harald
    Eschner, Wolfgang
    Zeitschrift fur Medizinische Physik, 2004, 14 (02): : 85 - 94
  • [10] COMPARISON OF TWO ANTHROPOMORPHIC PHANTOMS AS A CALIBRATION TOOL FOR WHOLE-BODY COUNTER USING MONTE CARLO SIMULATIONS
    Manohari, M.
    Mathiyarasu, R.
    Rajagopal, V.
    Venkatraman, B.
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 298 - 303