this work aims to report the influence of ambient humidity on partial discharge inception voltage (PDIV) and lifetime (endurance) of the insulation for inverter-fed motors. The PDIV on polyimide film and rotor bar insulated by NOMEX at sinusoidal voltages with 50 Hz frequency and the endurance tests of inverter-fed motor turn insulation under repetitive unipolar impulsive voltages with 10 ns rise time and 200 ns voltage on-time were performed at four relative humidity (RH), i.e. 40% 60%, 80% 95%, controlling the ambient temperature at 50 degrees C . Experimental results show that both the PDIV and endurance decrease significantly with increasing RH. Accordingly, the influence of ambient humidity on the test results should be carefully considered when performing PDIV and endurance tests on the insulation of low-voltage and high-voltage inverter-fed motors according to IEC standards.
引用
收藏
页码:201 / 204
页数:4
相关论文
共 50 条
  • [11] Insulation Failure of Inter-Turn Insulation in Inverter-fed Traction Motor
    Luo, Y.
    Wu, G. N.
    Wang, P.
    Cao, K. J.
    Cui, Y.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 831 - 834
  • [12] The Effect of Impulsive Voltage Rise Time on Insulation Endurance of Inverter-fed Motors
    Wang, Peng
    Cavallini, Andrea
    Montanari, Gian Carlo
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 84 - 87
  • [13] Temperature Effects on PD Statistics and Endurance of Inverter-fed Motor Insulation under Repetitive Square Wave Voltages
    Wang, Peng
    Xu, Hongying
    Wang, Jian
    Cavallini, Andrea
    Montanari, Gian Carlo
    2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 202 - 205
  • [14] Low-voltage PWM inverter-fed motor insulation issues
    Melfi, MJ
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (01) : 128 - 133
  • [15] Fillet Radius Impact of Rectangular Insulated Wires on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors
    Naderiallaf, Hadi
    Degano, Michele
    Gerada, Chris
    Gerada, David
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (04) : 2084 - 2093
  • [16] PD Electromagnetic Emission of Turn-to-Turn Insulation in Inverter-Fed Motor
    Ma, Shijin
    Wang, Peng
    Cavallini, Andrea
    Zhu, Yingwei
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (06) : 3049 - 3056
  • [17] Improved Modelling of PDIV Evolution Over Time Under Multiple Ageing Factors for Insulation of Inverter-Fed Electrical Machines
    Pietrzak, Pawel
    Malec, David
    Picot, Antoine
    Maussion, Pascal
    Hamiti, Tahar
    Benmamas, Loucif
    Manfe, Philippe
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (05) : 5329 - 5340
  • [18] Temperature Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors: From Ground Level to Cruising Altitude
    Naderiallaf, Hadi
    Ji, Yatai
    Giangrande, Paolo
    Galea, Michael
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (02) : 1044 - 1053
  • [19] Influence of Repetitive Impulse Wave Voltage Duty Cycle on Partial Discharge Statistics in Inverter-fed Motor Insulation
    Xu H.
    Zhao L.
    Wang P.
    Wang J.
    Zhou W.
    Li J.
    2017, Chinese Society for Electrical Engineering (37): : 2159 - 2166
  • [20] Effect of high frequency conducted disturbances on the interturn insulation of an inverter-fed induction motor
    Candela, R
    Petrarca, C
    Romano, P
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 510 - 513