Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery

被引:13
|
作者
Tognetto, Daniele [1 ]
Pastore, Marco R. [1 ]
De Giacinto, Chiara [1 ]
Merli, Riccardo [1 ]
Franzon, Marco [2 ]
D'Aloisio, Rossella [1 ]
Belfanti, Lorenzo [1 ]
Giglio, Rosa [1 ]
Cirigliano, Gabriella [1 ]
机构
[1] Univ Trieste, Dept Med Surg Sci & Hlth, Eye Clin, I-34129 Trieste, Italy
[2] Univ Trieste, Dept Math & Comp Sci, I-34129 Trieste, Italy
关键词
MORPHOLOGY; DEVICE; EYES;
D O I
10.1038/s41598-019-46243-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall's Coefficient of 0.83 (range 0.76-0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86-0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery
    Daniele Tognetto
    Marco R. Pastore
    Chiara De Giacinto
    Riccardo Merli
    Marco Franzon
    Rossella D’Aloisio
    Lorenzo Belfanti
    Rosa Giglio
    Gabriella Cirigliano
    Scientific Reports, 9
  • [2] Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery
    Hirnschall, Nino
    Leisser, Christoph
    Radda, Stephan
    Maedel, Sophie
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 530 - 536
  • [3] Utility of IOLMaster 700 Swept-Source Optical Coherence Tomography in Detecting Macular Disease for Preoperative Cataract Surgery Patients
    Ma, Jeffrey
    Pathak, Chintan
    Ramaprasad, Abhijit
    Basti, Surendra
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 3369 - 3378
  • [4] Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
    Huang, Jinhai
    Zhao, Yuyu
    Savini, Giacomo
    Yu, Guanshun
    Yu, Jinjin
    Chen, Zhongxing
    Tu, Ruixue
    Zhao, Yune
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [5] Swept-source optical coherence tomography to screen for macular pathology in eyes having routine cataract surgery
    Zafar, Sidra
    Siddiqui, M. A. Rehman
    Shahzad, Rida
    Shahzad, Masroor H.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (03): : 324 - 327
  • [6] Refractive surprise after cataract surgery secondary to smeared optics of swept-source optical coherence tomography biometer: a case report
    Francis Carr
    Vinod Gangwani
    BMC Ophthalmology, 20
  • [7] Refractive surprise after cataract surgery secondary to smeared optics of swept-source optical coherence tomography biometer: a case report
    Carr, Francis
    Gangwani, Vinod
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [8] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Dominguez-Vicent, Alberto
    Venkataraman, Abinaya Priya
    Dalin, Amanda
    Brautaset, Rune
    Montes-Mico, Robert
    EYE AND VISION, 2023, 10 (01)
  • [9] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Alberto Domínguez-Vicent
    Abinaya Priya Venkataraman
    Amanda Dalin
    Rune Brautaset
    Robert Montés-Micó
    Eye and Vision, 10
  • [10] Cataract quantification using swept-source optical coherence tomography
    Bras, Joao E. G.
    Sickenberger, Wolfgang
    Hirnschall, Nino
    Findl, Oliver