Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy

被引:107
|
作者
Lin, G. [1 ]
Nishimura, R. A. [1 ]
Gersh, B. J. [4 ]
Phil, D. [1 ]
Ommen, S. R. [1 ]
Ackerman, M. J. [2 ,3 ]
Brady, P. A. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Med, Rochester, MN 55905 USA
[3] Mayo Clin, Div Pediat Cardiol, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Pediat & Adolescent Med, Rochester, MN 55905 USA
关键词
SUDDEN CARDIAC DEATH; RISK; PREVENTION; THERAPY; DETERMINANTS; MYECTOMY;
D O I
10.1136/hrt.2008.150656
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although the benefit of implantable cardioverter defibrillator (ICD) therapy in patients with hypertrophic cardiomyopathy (HCM) at risk for sudden cardiac arrest is well established, there may be a higher risk for device complications and inappropriate shocks. Objectives: To determine the incidence of inappropriate ICD shocks and device complications in HCM patients and the impact of young age at ICD implant and atrial fibrillation. Methods: HCM patients who underwent ICD implantation between January 1988 and December 2005 were included. The frequency of device complications, including pneumothorax, pericardial effusion, haematoma, lead revisions, infection and rate of inappropriate shocks, was determined. ICD shocks were characterised as inappropriate if triggered by sinus tachycardia, atrial fibrillation or device malfunction. Results: A total of 181 patients were included (mean age 44 (SD 17) years; 62% males). During a mean follow-up of 59 (42) months (4.92 years; 830.75 patient-years), 65 patients (36%) had a total of 88 device complications, including 42 (23%) patients with inappropriate shocks. The rate of inappropriate shocks was 5.3% per year (vs 4% risk of appropriate shocks), and the likelihood of inappropriate ICD shocks per 100 patient-years was 5.1. Younger age and atrial fibrillation were associated with an increased risk of inappropriate ICD discharges. Conclusions: The rate of inappropriate ICD shocks and frequency of device complications in HCM patients are not insignificant and are most common in younger patients and those with atrial fibrillation. Inappropriate ICD shocks are the most common device complication and should be accounted for when counselling high-risk HCM patients for ICD implantation.
引用
收藏
页码:709 / 714
页数:6
相关论文
共 50 条
  • [41] Predictors and Clinical Impact of Inappropriate Implantable Cardioverter-Defibrillator Shocks in Korean Patients
    Yang, Jeong Hoon
    Byeon, Kyeongmin
    Yim, Hye Ran
    Park, Jung Wae
    Park, Seung-Jung
    Huh, June
    Kim, June Soo
    On, Young Keun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2012, 27 (06) : 619 - 624
  • [42] Inappropriate shocks after implantable cardioverter-defibrillator for primary prevention in idiopathic cardiomyopathy: Independent determinants
    Safak, Erdal
    D'Ancona, Giuseppe
    Ince, Hueseyin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 223 : 512 - 513
  • [43] Inappropriate implantable cardioverter-defibrillator shocks in a public swimming pool
    Alzand, Becker S. N.
    Leemput, Niels
    Willems, Rik
    EUROPACE, 2014, 16 (08): : 1124 - 1124
  • [44] HEALTHCARE UTILIZATION AND COSTS OF TREATING PATIENTS EXPERIENCING INAPPROPRIATE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SHOCKS
    Coleman, Craig I.
    Giedrimiene, Dalia
    Bhavnani, Sanjeev
    Azeem, Meena
    Kluger, Jeffrey
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1580 - E1580
  • [45] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EVALUATING SUSPECTED INAPPROPRIATE SHOCKS
    CHAPMAN, PD
    TROUP, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (05) : 1075 - 1078
  • [46] Apparent inappropriate shocks from an implantable cardioverter defibrillator: What is the mechanism?
    Moore, DR
    Kok, LC
    Vijayaraman, P
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (01) : 116 - 117
  • [47] Effectiveness of subcutaneous implantable cardioverter-defibrillator testing in patients with hypertrophic cardiomyopathy
    Maurizi, Niccolo
    Tanini, Ilaria
    Olivotto, Iacopo
    Amendola, Ernesto
    Limongelli, Giuseppe
    Losi, Maria Angela
    Allocca, Giuseppe
    Perego, Giovanni Battista
    Pieragnoli, Paolo
    Ricciardi, Giuseppe
    De Filippo, Paolo
    Ferrari, Paola
    Quarta, Giovanni
    Viani, Stefano
    Rapacciuolo, Antonio
    Bongiorni, Maria Grazia
    Cecchi, Franco
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 231 : 115 - 119
  • [48] Indications for Implantable Cardioverter-Defibrillator Placement in Pediatric Patients With Hypertrophic Cardiomyopathy
    Santamaria, Lizano Ramiro W.
    Fan, Chun-Po S.
    Runeckles, Kyle
    Grosse-Wortmann, Lars
    Stephenson, Elizabeth
    Benson, Lee
    CIRCULATION, 2018, 138
  • [49] An Automated System for Analysis of Implantable Cardioverter Defibrillator Reports in Hypertrophic Cardiomyopathy Patients
    Moon, Sungrim
    Wen, Andrew
    Scott, Christopher G.
    Noseworthy, Peter A.
    Geske, Jeffrey G.
    Shellum, Jane L.
    Chaudhry, Rajeev
    Ommen, Steve R.
    Nishimura, Rick A.
    Liu, Hongfang
    Arruda-Olson, Adelaide
    CIRCULATION, 2018, 138
  • [50] Circadian rhythm of appropriate implantable cardioverter defibrillator discharges in patients with hypertrophic cardiomyopathy
    Kiernan, Thomas J.
    Weivoda, Peggy L.
    Somers, Virend K.
    Ommen, Steve R.
    Gersh, Bernard J.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (10): : 1253 - 1258