Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy

被引:107
|
作者
Lin, G. [1 ]
Nishimura, R. A. [1 ]
Gersh, B. J. [4 ]
Phil, D. [1 ]
Ommen, S. R. [1 ]
Ackerman, M. J. [2 ,3 ]
Brady, P. A. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Med, Rochester, MN 55905 USA
[3] Mayo Clin, Div Pediat Cardiol, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Pediat & Adolescent Med, Rochester, MN 55905 USA
关键词
SUDDEN CARDIAC DEATH; RISK; PREVENTION; THERAPY; DETERMINANTS; MYECTOMY;
D O I
10.1136/hrt.2008.150656
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although the benefit of implantable cardioverter defibrillator (ICD) therapy in patients with hypertrophic cardiomyopathy (HCM) at risk for sudden cardiac arrest is well established, there may be a higher risk for device complications and inappropriate shocks. Objectives: To determine the incidence of inappropriate ICD shocks and device complications in HCM patients and the impact of young age at ICD implant and atrial fibrillation. Methods: HCM patients who underwent ICD implantation between January 1988 and December 2005 were included. The frequency of device complications, including pneumothorax, pericardial effusion, haematoma, lead revisions, infection and rate of inappropriate shocks, was determined. ICD shocks were characterised as inappropriate if triggered by sinus tachycardia, atrial fibrillation or device malfunction. Results: A total of 181 patients were included (mean age 44 (SD 17) years; 62% males). During a mean follow-up of 59 (42) months (4.92 years; 830.75 patient-years), 65 patients (36%) had a total of 88 device complications, including 42 (23%) patients with inappropriate shocks. The rate of inappropriate shocks was 5.3% per year (vs 4% risk of appropriate shocks), and the likelihood of inappropriate ICD shocks per 100 patient-years was 5.1. Younger age and atrial fibrillation were associated with an increased risk of inappropriate ICD discharges. Conclusions: The rate of inappropriate ICD shocks and frequency of device complications in HCM patients are not insignificant and are most common in younger patients and those with atrial fibrillation. Inappropriate ICD shocks are the most common device complication and should be accounted for when counselling high-risk HCM patients for ICD implantation.
引用
收藏
页码:709 / 714
页数:6
相关论文
共 50 条
  • [21] Implantable cardioverter defibrillator shocks: Appropriate versus inappropriate in MADIT II patients
    Lin, G.
    Brady, P.
    HEART, 2007, 93 : A66 - A66
  • [22] Appropriate therapy but not inappropriate shocks predict survival in implantable cardioverter defibrillator patients
    Dichtl, W.
    Wolber, T.
    Paoli, U.
    Bruellmann, S.
    Stuehlinger, M.
    Berger, T.
    Haegeli, L.
    Duru, F.
    Pachinger, O.
    Hintringer, F.
    EUROPEAN HEART JOURNAL, 2010, 31 : 838 - 838
  • [23] Multiple inappropriate shocks precipitated by interrogation of an implantable cardioverter defibrillator
    Hunn, RH
    Ashbaugh, TJ
    Calderini, M
    Anderson, KP
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06): : 1329 - 1330
  • [24] Inappropriate implantable cardioverter-defibrillator shocks in MADIT II
    Daubert, James P.
    Zareba, Wojciech
    Cannom, David S.
    McNitt, Scott
    Rosero, Spencer Z.
    Wang, Paul
    Schuger, Claudio
    Steinberg, Jonathan S.
    Higgins, Steven L.
    Wilber, David J.
    Klein, Helmut
    Andrews, Mark L.
    Hall, W. Jackson
    Moss, Arthur J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (14) : 1357 - 1365
  • [25] An unusual cause of inappropriate shocks delivered by an implantable cardioverter defibrillator
    Baldauf, Benito
    Lau, Ernest W.
    Giaccardi, Marzia
    Bonnemeier, Hendrik
    BMC CARDIOVASCULAR DISORDERS, 2024, 24 (01):
  • [26] Methods of minimizing inappropriate implantable cardioverter-defibrillator shocks
    Schaer B.
    Osswald S.
    Current Cardiology Reports, 2000, 2 (4) : 346 - 352
  • [27] Single Coil Implantable Cardioverter Defibrillator Leads in Patients With Hypertrophic Cardiomyopathy
    Kumar, Kartik R.
    Mandleywala, Swati N.
    Madias, Christopher
    Weinstock, Jonathan
    Rowin, Ethan J.
    Maron, Barry J.
    Maron, Martin S.
    Link, Mark S.
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (12): : 1896 - 1900
  • [28] Eligibility for the Subcutaneous Implantable Cardioverter-Defibrillator in Patients With Hypertrophic Cardiomyopathy
    Francia, Pietro
    Adduci, Carmen
    Palano, Francesca
    Semprini, Lorenzo
    Serdoz, Andrea
    Montesanti, Dalma
    Santini, Daria
    Musumeci, Beatrice
    Salvati, Adriano
    Volpe, Massimo
    Autore, Camillo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (08) : 893 - 899
  • [29] Clinical outcome in patients with hypertrophic cardiomyopathy and implantable cardioverter defibrillator therapy
    Schukro, Christoph
    Rosenhek, Raphael
    Pezawas, Thomas
    Stix, Johannes
    Kastner, Johannes
    Wolzt, Michael
    Schmidinger, Herwig
    WIENER KLINISCHE WOCHENSCHRIFT, 2009, 121 (15-16) : A36 - A37
  • [30] Subcutaneous Implantable Cardioverter Defibrillator in Patients With Hypertrophic Cardiomyopathy: An Initial Experience
    Weinstock, Jonathan
    Bader, Yousef H.
    Maron, Martin S.
    Rowin, Ethan J.
    Link, Mark S.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (02):