Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy

被引:107
|
作者
Lin, G. [1 ]
Nishimura, R. A. [1 ]
Gersh, B. J. [4 ]
Phil, D. [1 ]
Ommen, S. R. [1 ]
Ackerman, M. J. [2 ,3 ]
Brady, P. A. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Med, Rochester, MN 55905 USA
[3] Mayo Clin, Div Pediat Cardiol, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Pediat & Adolescent Med, Rochester, MN 55905 USA
关键词
SUDDEN CARDIAC DEATH; RISK; PREVENTION; THERAPY; DETERMINANTS; MYECTOMY;
D O I
10.1136/hrt.2008.150656
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although the benefit of implantable cardioverter defibrillator (ICD) therapy in patients with hypertrophic cardiomyopathy (HCM) at risk for sudden cardiac arrest is well established, there may be a higher risk for device complications and inappropriate shocks. Objectives: To determine the incidence of inappropriate ICD shocks and device complications in HCM patients and the impact of young age at ICD implant and atrial fibrillation. Methods: HCM patients who underwent ICD implantation between January 1988 and December 2005 were included. The frequency of device complications, including pneumothorax, pericardial effusion, haematoma, lead revisions, infection and rate of inappropriate shocks, was determined. ICD shocks were characterised as inappropriate if triggered by sinus tachycardia, atrial fibrillation or device malfunction. Results: A total of 181 patients were included (mean age 44 (SD 17) years; 62% males). During a mean follow-up of 59 (42) months (4.92 years; 830.75 patient-years), 65 patients (36%) had a total of 88 device complications, including 42 (23%) patients with inappropriate shocks. The rate of inappropriate shocks was 5.3% per year (vs 4% risk of appropriate shocks), and the likelihood of inappropriate ICD shocks per 100 patient-years was 5.1. Younger age and atrial fibrillation were associated with an increased risk of inappropriate ICD discharges. Conclusions: The rate of inappropriate ICD shocks and frequency of device complications in HCM patients are not insignificant and are most common in younger patients and those with atrial fibrillation. Inappropriate ICD shocks are the most common device complication and should be accounted for when counselling high-risk HCM patients for ICD implantation.
引用
收藏
页码:709 / 714
页数:6
相关论文
共 50 条
  • [1] The survival, efficacy and complications of implantable cardioverter defibrillator therapy in patients with hypertrophic cardiomyopathy
    Vriesendorp, P. A.
    Schinkel, A. F. L.
    Theuns, D. A. M. J.
    Van Slegtenhorst, M. A.
    Wessels, M. W.
    Jordaens, L. J. L. M.
    Ten Cate, F. J.
    Michels, M.
    EUROPEAN HEART JOURNAL, 2012, 33 : 542 - 542
  • [2] Complications of Implantable Cardioverter Defibrillator and Their Potential Risk Factors in Patients with Hypertrophic Cardiomyopathy
    Goudarzi, Mohammad Taghi Hedayati
    Moradi, Maryam
    Abrotan, Saeed
    Saravi, Mehrdad
    Shirafkan, Hoda
    Irilouzadian, Rana
    Omran, Hossein Salehi
    CARDIOLOGY RESEARCH AND PRACTICE, 2023, 2023
  • [3] Biventricular implantable cardioverter defibrillator and inappropriate shocks
    Srivathsan, K
    Bazzell, JL
    Lee, RW
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (01) : 88 - 89
  • [4] Incidence and causes of inappropriate shocks in patients with implantable cardioverter/defibrillator
    Schukro, C.
    Siebermair, J.
    Stix, G.
    Kastner, J.
    Pezawas, T.
    Wolzt, M.
    Schmidinger, H.
    EUROPEAN HEART JOURNAL, 2008, 29 : 645 - 645
  • [5] APPROPRIATE AND INAPPROPRIATE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY IN PATIENTS WITH HYPERTROPHIC CARDIOMYOPATHY: INCIDENCE AND PREDICTORS
    Min, David B.
    Masri, Ahmad
    Popovic, Zoran
    Kanj, Mohamed
    Smedira, Nicholas
    Lytle, Bruce
    Thamilarasan, Maran
    Lever, Harry
    Desai, Milind
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A319 - A319
  • [6] Younger Age Increases the Risk for Inappropriate Shocks in Hypertrophic Cardiomyopathy Patients With Implantable Cardioverter Defibrillators
    McCambridge, Amanda J.
    Fenstad, Eric R.
    Sheldon, Seth H.
    Sugrue, Alan M.
    Geske, Jeffrey B.
    Ommen, Steve R.
    Gersh, Bernard J.
    CIRCULATION, 2014, 130
  • [7] Tactics for the Reduction of Inappropriate Implantable Cardioverter Defibrillator Shocks
    Okuyama, Yuji
    CIRCULATION JOURNAL, 2010, 74 (07) : 1290 - 1291
  • [8] INAPPROPRIATE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SHOCKS INCREASE MORTALITY
    Van Rees, Johannes B.
    Borleffs, C. Jan Willem
    de Bie, Mihaly K.
    Stijnen, Theo
    van Erven, Lieselot
    Bax, Jeroen J.
    Schalij, Martin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [9] Hypertrophic cardiomyopathy and the implantable cardioverter-defibrillator
    Manovel-Sanchez, Ana J.
    Pedrote-Martinez, Alonso
    Arana-Rueda, Eduardo
    de Tejada, Francisco Errazquin-Saenz
    REVISTA ESPANOLA DE CARDIOLOGIA, 2007, 60 (07): : 784 - 784
  • [10] Implantable cardioverter defibrillator in patients with hypertrophic cardiomyopathy - A nationwide study
    Amin, A.
    Tsangaris, A.
    Arora, A.
    Satya, K.
    EUROPEAN HEART JOURNAL, 2018, 39 : 54 - 55