Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging

被引:3
|
作者
Leva, Lucia [1 ]
Matheoud, Roberta [2 ]
Sacchetti, Gianmauro [1 ]
Carriero, Alessandro [3 ]
Brambilla, Marco [2 ]
机构
[1] Univ Hosp Maggiore della Carita, Dept Nucl Med, Novara, Italy
[2] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[3] Univ Hosp Maggiore della Carita, Dept Radiol, Novara, Italy
关键词
CAD; gated SPECT; instrumentation; perfusion agents; statistical analysis; ITERATIVE RECONSTRUCTION ALGORITHMS; MYOCARDIAL-PERFUSION SPECT; RESOLUTION RECOVERY; VOLUME MEASUREMENTS; VALIDATION; SYSTEM; QUANTIFICATION; ASSOCIATION; ACQUISITION; PARAMETERS;
D O I
10.1007/s12350-018-1457-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference. Methods Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators. The values of the different datasets were compared using the Bland-Altman analysis method: the bias and the limits of agreement (LA) were estimated in a head-to-head comparison of the three protocols. Results In the (Method A-Method C) comparison for LVEF, the bias was 3.8% and the LAs ranged from - 9.3% to 16.8%. The agreement was still lower between Method B and C, whilst only slightly improved when Methods A and B were compared. Conclusions The wide amplitude in LA intervals of about 30% indicates that IQ and LEHR GSPECT are not interchangeable. The values obtained with IQ-SPECT should only be used with caution when evaluating the functional state of the heart.
引用
收藏
页码:1714 / 1724
页数:11
相关论文
共 50 条
  • [31] Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes
    Riemer H. J. A. Slart
    René A. Tio
    Clark J. Zeebregts
    Antoon T. M. Willemsen
    Rudi A. J. O. Dierckx
    Johan De Sutter
    Annals of Nuclear Medicine, 2008, 22 : 171 - 176
  • [32] A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT
    Dustin Kliner
    Li Wang
    Daniel Winger
    William P. Follansbee
    Prem Soman
    Journal of Nuclear Cardiology, 2015, 22 : 1237 - 1243
  • [33] A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT
    Kliner, Dustin
    Wang, Li
    Winger, Daniel
    Follansbee, William P.
    Soman, Prem
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (06) : 1237 - 1243
  • [34] Left ventricular ejection fraction: Gated blood pool SPECT versus myocardial perfusion gated SPECT.
    Daou, D
    Coaguila, C
    Vilain, D
    Lebtahi, R
    Benelhadj, S
    Fourme, T
    Colin, P
    Idy-Peretti, I
    Slama, M
    Le Guludec, D
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 97P - 97P
  • [35] Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes
    Slart, Riemer H. J. A.
    Tio, Rene A.
    Zeebregts, Clark J.
    Willemsen, Antoon T. M.
    Dierckx, Rudi A. J. O.
    De Sutter, Johan
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (03) : 171 - 176
  • [36] COMPARISON OF GATED SPECT WITH CARDIAC CT FOR THE ASSESSMENT OF LEFT VENTRICULAR VOLUMES AND LEFT VENTRICULAR EJECTION FRACTION
    Subramanian, L.
    Warrington, J. C.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2012, 181 : S455 - S456
  • [37] The relation between left ventricular ejection fraction and perfusion defect size by gated SPECT myocardial perfusion imaging in patients with coronary artery disease
    Aljaroudi, W.
    Mundkur, M.
    Heo, J.
    Iskandrian, A. E.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 55 (06): : 688 - 693
  • [38] Comparative study of IQ-SPECT and conventional SPECTGated Myocardial Perfusion Imaging
    Biao, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S824 - S824
  • [39] Comparison of left ventricular ejection fraction assessment by echocardiography and gated SPECT: data from 2870 patients
    Rogers, B. A.
    Khandekar, S.
    Gupta, A.
    Jaber, W. A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 561 - 562
  • [40] Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy
    Feng Wang
    Jian Zhang
    Wei Fang
    Shi-Hua Zhao
    Min-Jie Lu
    Zuo-Xiang He
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1611 - 1621