Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging

被引:3
|
作者
Leva, Lucia [1 ]
Matheoud, Roberta [2 ]
Sacchetti, Gianmauro [1 ]
Carriero, Alessandro [3 ]
Brambilla, Marco [2 ]
机构
[1] Univ Hosp Maggiore della Carita, Dept Nucl Med, Novara, Italy
[2] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[3] Univ Hosp Maggiore della Carita, Dept Radiol, Novara, Italy
关键词
CAD; gated SPECT; instrumentation; perfusion agents; statistical analysis; ITERATIVE RECONSTRUCTION ALGORITHMS; MYOCARDIAL-PERFUSION SPECT; RESOLUTION RECOVERY; VOLUME MEASUREMENTS; VALIDATION; SYSTEM; QUANTIFICATION; ASSOCIATION; ACQUISITION; PARAMETERS;
D O I
10.1007/s12350-018-1457-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference. Methods Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators. The values of the different datasets were compared using the Bland-Altman analysis method: the bias and the limits of agreement (LA) were estimated in a head-to-head comparison of the three protocols. Results In the (Method A-Method C) comparison for LVEF, the bias was 3.8% and the LAs ranged from - 9.3% to 16.8%. The agreement was still lower between Method B and C, whilst only slightly improved when Methods A and B were compared. Conclusions The wide amplitude in LA intervals of about 30% indicates that IQ and LEHR GSPECT are not interchangeable. The values obtained with IQ-SPECT should only be used with caution when evaluating the functional state of the heart.
引用
收藏
页码:1714 / 1724
页数:11
相关论文
共 50 条
  • [21] Assessment of left ventricular ejection fraction measured by quantitative gated SPECT
    Abe, K
    Hirakawa, K
    Yonenaga, T
    Kobayashi, S
    Nishimura, M
    Ayabe, Z
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (02): : 223 - 230
  • [22] Reproducibility of left ventricular ejection fraction calculated from gated spect
    Buyukdereli, G.
    Polat, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S235 - S235
  • [23] The Impact of Acquisition Time on Left Ventricular Volumes and Ejection Fraction of Gated Myocardial SPECT Imaging
    Han, P. P.
    Tian, Y. Q.
    Li, J. J.
    He, Z. X.
    CARDIOLOGY, 2010, 117 : 100 - 101
  • [24] Biological factors and overestimation of left ventricular ejection fraction by gated SPECT
    Conde de Oliveira, Marco Antonio
    Duarte, Paulo Schiavom
    Gonzalez, Maria Margarita C.
    Moises, Valdir Ambrosio
    Alonso, Gilberto
    Lima, Eduardo Vilaca
    Smanio, Paola Emanuela
    Fernandes Martins, Luiz Roberto
    Oliveira, Carlos A. R.
    Mastrocolla, Luiz Eduardo
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2008, 90 (05) : 333 - 338
  • [25] Keeping the reproducibility of functional parameters of the left ventricle between conventional system and IQ-SPECT
    Havel, M.
    Kaminek, M.
    Henzlova, L.
    Koranda, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S559 - S559
  • [26] LEFT-VENTRICULAR EJECTION FRACTION ASSESSED FROM GATED TECHNETIUM-99M-SESTAMIBI SPECT
    DEPUEY, EG
    NICHOLS, K
    DOBRINSKY, C
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (11) : 1871 - 1876
  • [27] Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging
    C. Marcassa
    R. Giubbini
    W. Acampa
    C. Cittanti
    O. Djepaxhija
    A. Gimelli
    A. Kokomani
    G. Medolago
    E. Milan
    R. Sciagrà
    Journal of Nuclear Cardiology, 2017, 24 : 1292 - 1301
  • [28] Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging
    Marcassa, C.
    Giubbini, R.
    Acampa, W.
    Cittanti, C.
    Djepaxhija, O.
    Gimelli, A.
    Kokomani, A.
    Medolago, G.
    Milan, E.
    Sciagra, R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1292 - 1301
  • [29] Comparison of IQ-SPECT/CT with conventional SPECT/CT for myocardial perfusion imaging
    Novak, Mackenzie
    Grancorvitz, Abigail
    Johnson, Carlyn
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [30] Comparison of left ventricular volumes and ejection fraction measured by gated SPECT and by cine magnetic resonance imaging
    He, ZX
    Vick, GW
    Vaduganathan, P
    Verani, MS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 44A - 44A