Assessment of the reproducibility and repeatability of a method of grading macular subretinal fluid using optical coherence tomography

被引:7
|
作者
Benson, S. E. [1 ]
Schlottmann, P. G. [1 ]
Bunce, C. [1 ]
Xing, W. [1 ]
Charteris, D. G. [1 ]
机构
[1] Moorfields Eye Hosp, London EC1V 2PD, England
关键词
optical coherence tomography; macula; grading; subretinal fluid;
D O I
10.1038/sj.eye.6702073
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To devise a quantative method for the measurement of the extent of macular subretinal fluid using optical coherence tomography (OCT), and to assess the interobserver and intraobserver agreement for this grading system. Methods Observational cohort series. Patients were a cohort who underwent retinal detachment surgery over an 18- month period. All patients had OCT scan at 6 weeks after surgery. The scans were graded by two independent observers experienced in OCT interpretation and each grader was masked to the others findings. Observer 1 then regraded the scans on a later day masked to his previous findings. The interobserver and intraobserver agreement was assessed using weighted Kappa ( Kw) statistics. Results In all, 116 patients were analysed. Both the intraobserver and interobserver agreement was very high, with Kw being 0.9631 and 0.9070, respectively. Conclusions The grading system for assessment of the extent of macular subretinal fluid using OCT appears to have very good reproducibility and repeatability. We propose that this grading system would be clinically useful when applied to pathologies visible on OCT scan of the macula.
引用
下载
收藏
页码:1030 / 1033
页数:4
相关论文
共 50 条
  • [21] Repeatability and reproducibility of optic nerve head perfusion measurements using optical coherence tomography angiography
    Chen, Chieh-Li
    Bojikian, Karine D.
    Xin, Chen
    Wen, Joanne C.
    Gupta, Divakar
    Zhang, Qinqin
    Mudumbai, Raghu C.
    Johnstone, Murray A.
    Chen, Philip P.
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
  • [22] Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema
    Krzystolik, Magdalena G.
    Strauber, Samara F.
    Ai-ello, Lloyd Paul
    Beek, Roy W.
    Berger, Brian B.
    Bressler, Neil M.
    Browning, David J.
    Chambers, Robert B.
    Danis, Ronald P.
    Davis, Matthew D.
    Glassman, Adam R.
    Gonzalez, Victor H.
    Greenberg, Paul B.
    Gross, Jeffrey G.
    Kim, Judy E.
    Kollman, Craig
    OPHTHALMOLOGY, 2007, 114 (08) : 1520 - 1525
  • [23] Idiopathic macular hole with extensive subretinal fluid: Clinical and optical coherence tomography features before and after surgery
    Kitchens, JW
    Flynn, HW
    Moshfeghi, AA
    Puliafito, CA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (02) : 383 - 386
  • [24] Repeatability and reproducibility of axial and lateral measurements on handheld optical coherence tomography systems
    McGeehan, Brendan
    Chen, Xi
    Tai, Vincent
    Ying, Gui-Shuang
    Viehland, Christian
    Imperio, Ryan
    Winter, Katrina
    Raynor, William
    Du Tran-Viet
    Mangalesh, Shwetha
    Maguire, Maureen
    Toth, Cynthia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [25] Interobserver reproducibility and interocular symmetry of the macular ganglion cell complex: assessment in healthy children using optical coherence tomography
    Munoz-Gallego, Alicia
    de la Cruz, Javier
    Rodriguez-Salgado, Martin
    Torres-Pena, Jose L.
    Sambricio, Javier
    Ortueta-Olartecoechea, Ana
    Tejada-Palacios, Pilar
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [26] Interobserver reproducibility and interocular symmetry of the macular ganglion cell complex: assessment in healthy children using optical coherence tomography
    Alicia Muñoz-Gallego
    Javier De la Cruz
    Martín Rodríguez-Salgado
    José L. Torres-Peña
    Javier Sambricio
    Ana Ortueta-Olartecoechea
    Pilar Tejada-Palacios
    BMC Ophthalmology, 20
  • [27] Reproducibility of macular thickness mapping on the commercial optical coherence tomography device
    MacNutt, JM
    Schuman, JS
    Guedes, VRF
    Miller, VM
    Pakter, HM
    Ghanta, RK
    Drexler, W
    Hertzmark, E
    Peiris, ID
    Puliafito, CA
    Fujimoto, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [28] Repeatability and Reproducibility of Manual Choroidal Volume Measurements Using Enhanced Depth Imaging Optical Coherence Tomography
    Chhablani, Jay
    Barteselli, Giulio
    Wang, Haiyan
    El-Emam, Sharif
    Kozak, Igor
    Doede, Aubrey L.
    Bartsch, Dirk-Uwe
    Cheng, Lingyun
    Freeman, William R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (04) : 2274 - 2280
  • [29] Anterior chamber depth measurements using Scheimpflug imaging and optical coherence tomography: Repeatability, reproducibility, and agreement
    Wang, Qinmei
    Ding, Xixia
    Savini, Giacomo
    Chen, Hao
    Feng, Yifan
    Pan, Chao
    Hua, Yanjun
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01): : 178 - 185
  • [30] Repeatability and reproducibility of automatic segmentation of retinal layers in healthy subjects using Spectralis optical coherence tomography
    Cetinkaya, Ersan
    Duman, Rahmi
    Duman, Resat
    Sabaner, Mehmet Cem
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (06) : 378 - 381