Ventricular fibrillation undersensing due to air entrapment in a patient implanted with a subcutaneous cardioverter defibrillator

被引:4
|
作者
Adduci, Carmen [1 ]
Spadoni, Loris [2 ]
Palano, Francesca [1 ]
Francia, Pietro [1 ]
机构
[1] Sapienza Univ, St Andrea Hosp, Div Cardiol, Dept Clin & Mol Med, Rome, Italy
[2] Boston Sci Italy, Milan, Italy
关键词
air entrapment; subcutaneous ICD; ventricular fibrillation undersensing;
D O I
10.1111/jce.14005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:1373 / 1374
页数:2
相关论文
共 50 条
  • [1] Undersensing of ventricular fibrillation in a noncommitted nonthoracotomy cardioverter defibrillator system
    Peralta, AO
    John, RM
    Venditti, FJ
    Martin, DT
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (03): : 610 - 618
  • [2] Undersensing of ventricular fibrillation due to interference between a pacemaker and defibrillator in the same patient
    Van Casteren, Lieve
    Huybrechts, Wim
    Willems, Rik
    EUROPACE, 2009, 11 (10): : 1390 - 1391
  • [3] Inappropriate Shock Due to Air Entrapment in the Pocket of a Subcutaneous Implantable Cardioverter-defibrillator
    Linhart, Markus
    Maria Tolosana, Jose
    Chipa, Fredy
    Trucco, Emilce
    Mont, Lluis
    REVISTA ESPANOLA DE CARDIOLOGIA, 2019, 72 (01): : 79 - 81
  • [4] Undersensing of ventricular fibrillation by a biventricular implantable cardioverter-defibrillator: What is the cause and the troubleshooting?
    Kien Vo Le
    Okamura, Hideo
    Nakajima, Kenzaburo
    Noda, Takashi
    Kusano, Kengo
    JOURNAL OF ARRHYTHMIA, 2019, 35 (02) : 276 - 278
  • [5] Ventricular fibrillation frequency from implanted cardioverter defibrillator devices
    Panfilov, Ilia
    Lever, Nigel A.
    Smaill, Bruce H.
    Larsen, Peter D.
    EUROPACE, 2009, 11 (08): : 1052 - 1056
  • [6] Air Entrapment Causing Inappropriate Shock From a Subcutaneous Implantable Cardioverter Defibrillator
    Yang, Ying Chi
    Thein Tun Aung
    Bailin, Steven J.
    Rhodes, Troy E.
    CARDIOLOGY RESEARCH, 2019, 10 (02) : 128 - 130
  • [7] Ventricular Fibrillation due to Automated Atrial Threshold Testing in a Patient with an Implantable Cardioverter Defibrillator
    Schellevis, Mindel M.
    Van Halm, Vokko P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (11): : 1355 - 1358
  • [8] Subcutaneous air entrapment after subcutaneous implantable cardioverter defibrillator implantation evaluated by computed tomography
    Taguchi, Yuka
    Ishikawa, Toshiyuki
    Matsumoto, Katsumi
    Narikawa, Masatoshi
    Okazaki, Yoshinori
    Miyagawa, Shuichi
    Horigome, Akira
    Hosoda, Junya
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (04): : 496 - 502
  • [9] Fracture of the subcutaneous patch electrode in a patient with an implanted cardioverter-defibrillator
    Milasinovic, G
    Jelic, V
    Savic, D
    Pavlovic, SU
    Velinovic, M
    CIRCULATION JOURNAL, 2005, 69 (01) : 116 - 118
  • [10] Signal-processing enhancement to reduce oversensing of T waves without increasing undersensing of ventricular fibrillation in the subcutaneous implantable cardioverter-defibrillator
    Nair, Sandeep G.
    Swerdlow, Charles D.
    HEART RHYTHM, 2018, 15 (10) : 1523 - 1524