Viral Clearance by Flow-Through Mode Ion Exchange Columns and Membrane Adsorbers

被引:29
|
作者
Miesegaes, G. R. [1 ]
Lute, S. C. [1 ]
Read, E. K. [1 ]
Brorson, K. A. [1 ]
机构
[1] CDER FDA, Off Biotechnol Prod, Silver Spring, MD 20903 USA
关键词
monoclonal antibodies; viral clearance; anion exchange chromatography; membrane adsorbers; downstream purification; design-of-experiments; DoE; VIRUS REMOVAL; CHROMATOGRAPHY; PURIFICATION; PROTEIN; ANTIBODIES; ROBUST; MEDIA; DNA;
D O I
10.1002/btpr.1832
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Anion exchange (AEX) is a common downstream purification operation for biotechnology products manufactured in cell culture such as therapeutic monoclonal antibodies (mAbs) and Fc-fusion proteins. We present a head-to-head comparison of the viral clearance efficiency of AEX adsorbers and column chromatography using the same process fluids and comparable run conditions. We also present overall trends from the CDER viral clearance database. In our comparison of multiple brands of resins and adsorbers, clearance of three model viruses (PPV, X-MuLV, and PR772) was largely comparable, with some exceptions which may reflect run conditions that had not been optimized on a resin/membrane specific basis. (c) 2013 American Institute of Chemical Engineers Biotechnol. Prog., 30:124-131, 2014
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [31] Ion-exchange membranes in gold electowinning processes on flow-through carbon fiber electrodes
    V. K. Varentsov
    I. A. Bataev
    Petroleum Chemistry, 2017, 57 : 961 - 968
  • [32] Ion-exchange membranes in gold electowinning processes on flow-through carbon fiber electrodes
    Varentsov, V. K.
    Bataev, I. A.
    PETROLEUM CHEMISTRY, 2017, 57 (11) : 961 - 968
  • [33] Purification of IgG from Sera of Rabbit and Guinea Pig by Flow-Through Mode Ion-Exchange Chromatography using DEAE Sepharose Fast Flow Column
    Wang, Ying
    Zhang, Peiyin
    Liu, Shujun
    Zhang, Yongsheng
    Zhao, Tiesuo
    Huang, Wenhui
    He, Chunyan
    Yu, Yongli
    Wang, Liying
    Wan, Min
    CHROMATOGRAPHIA, 2011, 74 (3-4) : 209 - 214
  • [34] Purification of IgG from Sera of Rabbit and Guinea Pig by Flow-Through Mode Ion-Exchange Chromatography using DEAE Sepharose Fast Flow Column
    Ying Wang
    Peiyin Zhang
    Shujun Liu
    Yongsheng Zhang
    Tiesuo Zhao
    Wenhui Huang
    Chunyan He
    Yongli Yu
    Liying Wang
    Min Wan
    Chromatographia, 2011, 74 : 209 - 214
  • [35] Purification of monoclonal antibodies entirely in flow-through mode
    Yamada, Tsuyoshi
    Yamamoto, Koichi
    Ishihara, Takashi
    Ohta, Shigeru
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1061 : 110 - 116
  • [36] Impact of the substrate viscosity, potentially interfering proteins and further sample characteristics on the ion exchange efficiency of tangential flow membrane adsorbers
    Brand, Janina
    Kulozik, Ulrich
    FOOD AND BIOPRODUCTS PROCESSING, 2017, 102 : 90 - 97
  • [37] A portable flow-through immunoassay system for bacterial and viral detection
    Abdel-Hamid, I
    Atanasov, P
    Wilkins, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U932 - U932
  • [38] CONSTANT FLOW DEVICE FOR ION-EXCHANGE COLUMNS
    MCCORMICK, PG
    JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (01) : 15 - 15
  • [39] A METHOD FOR STUDYING DIAGENESIS IN SHALLOW SEDIMENTS USING FLOW-THROUGH COLUMNS
    FRYAR, AE
    SCHWARTZ, FW
    JOURNAL OF SEDIMENTARY RESEARCH SECTION A-SEDIMENTARY PETROLOGY AND PROCESSES, 1994, 64 (03): : 679 - 681
  • [40] FLOW-THROUGH ELECTRODE UNIT FOR LIQUID MEMBRANE ELECTRODES
    PAPASTATHOPOULOS, DS
    DIAMANDIS, EP
    HADJIIOANNOU, TP
    ANALYTICAL CHEMISTRY, 1980, 52 (13) : 2100 - 2104