Purification of IgG from Sera of Rabbit and Guinea Pig by Flow-Through Mode Ion-Exchange Chromatography using DEAE Sepharose Fast Flow Column

被引:1
|
作者
Ying Wang
Peiyin Zhang
Shujun Liu
Yongsheng Zhang
Tiesuo Zhao
Wenhui Huang
Chunyan He
Yongli Yu
Liying Wang
Min Wan
机构
[1] Jilin University,Department of Molecular Biology, Norman Bethune College of Medicine
[2] Jilin University,Department of Immunology, Norman Bethune College of Medicine
[3] Jilin University,Department of Nephropathy, The Second Hospital
来源
Chromatographia | 2011年 / 74卷
关键词
Flow-through mode ion-exchange chromatography; Immunoglobulin G (IgG); Purification; pH value;
D O I
暂无
中图分类号
学科分类号
摘要
A one-step purification process using flow-through mode ion-exchange chromatography (Ft-IEC) was evaluated for the purification of Immunoglobulin G (IgG) from rabbit and guinea pig serum. A simple protein precipitation with saturated ammonium sulfate was used to pretreated plasma samples. Chromatographic separation was carried out on DEAE Sepharose Fast Flow (F.F.) column at a flow rate of 1 mL min−1. Ft-IEC using Tris–HCl buffer at pH 7.0 allowed the recovery of 22% of the loaded IgG with purity of 95% existed in flowthrough and washing effluents but not in elution effluents. To be compared, bind-elute mode IEC using Tris–HCl buffer at pH 8.5 based on the routine protocol showed that the recovery of 15% of the loaded IgG with purity of 80% existed in elution effluents. These results indicate that the Ft-IEC is an effective method for purifying IgG from sera of rabbit and guinea pig and may also be suitable for other animal sera by adjusting pH at equilibrium buffer for chromatography column.
引用
收藏
页码:209 / 214
页数:5
相关论文
共 20 条
  • [1] Purification of IgG from Sera of Rabbit and Guinea Pig by Flow-Through Mode Ion-Exchange Chromatography using DEAE Sepharose Fast Flow Column
    Wang, Ying
    Zhang, Peiyin
    Liu, Shujun
    Zhang, Yongsheng
    Zhao, Tiesuo
    Huang, Wenhui
    He, Chunyan
    Yu, Yongli
    Wang, Liying
    Wan, Min
    CHROMATOGRAPHIA, 2011, 74 (3-4) : 209 - 214
  • [2] Purification of hemoglobin by ion exchange chromatography in flow-through mode with PEG as an escort
    Lu, XL
    Zhao, DX
    Su, ZG
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2004, 32 (02): : 209 - 227
  • [3] Chromatography of human prothrombin from Nitschmann fraction III on DEAE Sepharose Fast Flow using axial and radial flow column
    Sun, T
    Chen, G
    Liu, YP
    Bu, FR
    Wen, MJ
    BIOMEDICAL CHROMATOGRAPHY, 2000, 14 (07) : 478 - 482
  • [4] A FLOW-THROUGH MICROSAMPLING DEVICE APPLIED TO AN ION-EXCHANGE CHROMATOGRAPHY SYSTEM
    NILSSON, J
    SZECSI, P
    SCHAFERNIELSEN, C
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1993, 27 (03): : 181 - 190
  • [6] Behavior of weakly adsorbing protein impurities in flow-through ion-exchange chromatography
    Herman, Chase E.
    Xu, Xuankuo
    Traylor, Steven J.
    Ghose, Sanchayita
    Li, Zheng Jian
    Lenhoff, Abraham M.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1664
  • [7] Removal of monoclonal antibody aggregates with ion exchange chromatography by flow-through mode
    Zhao Y.
    Zhang X.
    Wang R.
    Sun G.
    Yao S.
    Lin D.
    Huagong Xuebao/CIESC Journal, 2023, 74 (09): : 3879 - 3887
  • [8] Chemiluminescence flow-through sensor for copper based on an anodic stripping voltammetric flow cell and an ion-exchange column with immobilized reagents
    Qin, W
    Zhang, ZJ
    Liu, HJ
    ANALYTICAL CHEMISTRY, 1998, 70 (17) : 3579 - 3584
  • [9] Chromatography of human prothrombin from Nitschmann fraction III on Q Sepharose Fast Flow using axial and radial flow column
    Tao, S
    Ge, C
    Liu, YP
    Bu, FR
    Wen, MJ
    BIOPROCESS ENGINEERING, 2000, 23 (02) : 121 - 125
  • [10] Chromatography of human prothrombin from Nitschmann fraction III on Q Sepharose Fast Flow using axial and radial flow column
    Sun Tao
    Chen Ge
    Liu Yipin
    Bu Fenfrong
    Wen Meijuan
    Bioprocess Engineering, 2000, 23 : 121 - 125