Chromatography of human prothrombin from Nitschmann fraction III on DEAE Sepharose Fast Flow using axial and radial flow column

被引:0
|
作者
Sun, T
Chen, G
Liu, YP
Bu, FR
Wen, MJ
机构
[1] Inst Transfus Med, Beijing 100850, Peoples R China
[2] Univ Sci & Technol Beijing, Dept Chem, Beijing 100083, Peoples R China
关键词
D O I
10.1002/1099-0801(200011)14:7<478::AID-BMC996>3.0.CO;2-P
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An axial column (3 x 2.6 cm) and a radial flow column (3.5 x 5 cm) packed with DEAE Sepharose Fast Flow media was evaluated for the separation of human prothrombin from Nitschmann fraction III. Under radial flow conditions, a sample flow rate up to 14 mL/min (approximately 18 bed vols/h) was achieved. Breakthrough capacity was determined and both columns had almost the same breakthrough capacity per mL media, indicating that the sample loading was independent of radial column geometry. Copyright (C) 2000 John Wiley & Sons, Ltd.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 26 条
  • [1] Chromatography of human prothrombin from Nitschmann fraction III on Q Sepharose Fast Flow using axial and radial flow column
    Tao, S
    Ge, C
    Liu, YP
    Bu, FR
    Wen, MJ
    BIOPROCESS ENGINEERING, 2000, 23 (02) : 121 - 125
  • [2] Chromatography of human prothrombin from Nitschmann fraction III on Q Sepharose Fast Flow using axial and radial flow column
    Sun Tao
    Chen Ge
    Liu Yipin
    Bu Fenfrong
    Wen Meijuan
    Bioprocess Engineering, 2000, 23 : 121 - 125
  • [3] Purification of human prothrombin from Nitschmann fraction III using DEAE membrane radial flow chromatography
    Sun, T
    Chen, G
    Liu, YP
    Bu, FR
    Wen, MJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 742 (01): : 109 - 114
  • [4] Isolation of human fibrinogen by axial and radial flow chromatography from Nitschmann fraction I
    Sun, T
    Chen, G
    Liu, YP
    Bu, FG
    Wen, MJ
    BIOTECHNOLOGY TECHNIQUES, 1999, 13 (12) : 831 - 835
  • [5] Purification of IgG from Sera of Rabbit and Guinea Pig by Flow-Through Mode Ion-Exchange Chromatography using DEAE Sepharose Fast Flow Column
    Ying Wang
    Peiyin Zhang
    Shujun Liu
    Yongsheng Zhang
    Tiesuo Zhao
    Wenhui Huang
    Chunyan He
    Yongli Yu
    Liying Wang
    Min Wan
    Chromatographia, 2011, 74 : 209 - 214
  • [6] Purification of IgG from Sera of Rabbit and Guinea Pig by Flow-Through Mode Ion-Exchange Chromatography using DEAE Sepharose Fast Flow Column
    Wang, Ying
    Zhang, Peiyin
    Liu, Shujun
    Zhang, Yongsheng
    Zhao, Tiesuo
    Huang, Wenhui
    He, Chunyan
    Yu, Yongli
    Wang, Liying
    Wan, Min
    CHROMATOGRAPHIA, 2011, 74 (3-4) : 209 - 214
  • [8] HIGH FLOW PSEUDO-AFFINITY PURIFICATION ON HISTIDYL SEPHAROSE OF A BIOLOGICALLY-ACTIVE BACTERIAL GLYCOPEPTIDE USING A RADIAL FLOW COLUMN
    AKOUM, A
    SIGOT, M
    VIJAYALAKSHMI, MA
    BIOLOGICAL CHEMISTRY HOPPE-SEYLER, 1987, 368 (07): : 733 - 733
  • [9] ISOLATION OF HUMAN HEMOPEXIN IN APO-FORM BY CHROMATOGRAPHY ON S-SEPHAROSE FAST FLOW AND BLUE SEPHAROSE CL-6B
    HRKAL, Z
    CABART, P
    KALOUSEK, I
    BIOMEDICAL CHROMATOGRAPHY, 1992, 6 (04) : 212 - 214
  • [10] INTERACTIONS BETWEEN HISTONE AND DNA FROM CALF AND HUMAN TISSUES USING ACTIVATED SEPHAROSE COLUMN CHROMATOGRAPHY
    AYAD, SR
    PARKER, MC
    JOURNAL OF CHROMATOGRAPHY, 1973, 82 (02): : 343 - 348