A new passive dosimetric system with thermoluminescent LiF: Mg, Cu, P detectors applied in individual radiation monitoring

被引:0
|
作者
Stochioiu, A. [1 ]
Mihai, F.
Scarlat, F.
机构
[1] Natl Inst Phys & Nucl Engn Horia Hulubei, Bucharest, Romania
[2] Natl Inst Laser Plasma & Radiat Phys, Bucharest, Romania
来源
关键词
dosimetry; thermoluminescent detectors; biological protection; radioactivity monitoring;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents the results of measuring the main parameters and characteristics of a new passive dosimetric system outfitted with thermo luminescent (TL) LiF Mg Cu P detectors for individual radiation monitoring, constructed in IFIN - HH. The presented dosimetric system is employed for measuring the equivalent absorbed dose of X, y and beta radiations within the energy range of 30 KeV - 3 MeV for a 1 to 90 days monitoring period. Among the parameters and characteristics of the new dosimetric system note: the homogeneity of the dosimetric response for a batch of 30 dosimeters is max. 10%; the dosimetric response repeatability is max. 3%; the measurement uncertainty within 7.5 mu Sv - 100 mSv range is max. 8%; the minimum traceable equivalent dose 70 nSv; loss of dosimetric response information in time is max. 2% per month and the variation of the dosimetric response with the incident radiation energy is max. 8%. The measurements and the system characterization were developed according to CEI 1066 standards previsions. The obtained values fall in the standard provisions. The paper also presents some constructive elements of the dosimetric system.
引用
收藏
页码:1545 / 1551
页数:7
相关论文
共 50 条
  • [41] Sensitivity changes of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors after proton exposures
    Sadel, M.
    Bilski, P.
    Swakon, J.
    Rydygier, M.
    RADIATION MEASUREMENTS, 2015, 74 : 26 - 30
  • [42] The light sensitivity of thermoluminescent materials:: LiF:Mg,Cu,P, LiF:Mg,Ti and Al2O3:C
    Duggan, L
    Budzanowski, M
    Przegietka, K
    Reitsema, N
    Wong, J
    Kron, T
    RADIATION MEASUREMENTS, 2000, 32 (04) : 335 - 342
  • [43] INDIVIDUAL MONITORING IN NUCLEAR MEDICINE THERAPEUTIC PROCEDURES USING EXTREMITY DOSEMETERS LiF(Mg, Cu, P)
    Sarti, G.
    Del Dottore, F.
    Fabbri, C.
    Tassinari, L.
    Pagan, S.
    Rustignoli, M.
    Motta, P.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 521 - 524
  • [44] LET-calibration of a new TLD-system LiF:Mg, Ti/LiF:Mg,Cu,P for let-determination in mixed radiation fields
    Torkzadeh, F
    Vana, N
    Noll, M
    Fugger, M
    RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 695 - 700
  • [45] EVALUATION OF THE PERFORMANCE OF TWO LiF:Mg,Ti AND LiF:Mg,Cu,P DOSEMETERS FOR EXTREMITY MONITORING
    Freire, L. C.
    Pereira, M. F.
    Calado, A. M.
    Santos, L. M.
    Cardoso, J. V.
    Alves, J. G.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 140 - 143
  • [46] LiF:Mg,Cu,P 'pin worms':: Miniature detectors for brachytherapy dosimetry
    Hood, C
    Duggan, L
    Bazley, S
    Denham, J
    Budzanowski, M
    Kron, T
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 407 - 410
  • [47] Ultra-thin LiF:Mg,Cu,P detectors for beta dosimetry
    Inst of Nuclear Physics, Krakow, Poland
    Radiat Meas, 4 (439-443):
  • [48] LiF:Mg,Cu,P 'Pin worms':: Miniature detectors for brachytherapy dosimetry
    Hood, C
    Duggan, L
    Bazley, S
    Denham, J
    Budzanowski, M
    Kron, T
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A407 - A410
  • [49] Spectrally resolved thermoluminescence of highly irradiated LiF:Mg,Cu,P detectors
    Mandowska, E.
    Bilski, P.
    Obryk, B.
    Mandowski, A.
    Olko, P.
    Kim, J.
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 579 - 582
  • [50] LIF-MG, CU, P TL DETECTORS WITH ADJUSTABLE ENERGY RESPONSES
    WANG, ST
    CAI, GG
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1991, 24 (11) : 2072 - 2075