Calcium and Phosphorus Detection Using Benchtop Versus Handheld X-ray Fluorescence Spectrometers

被引:9
|
作者
Kuzel, Aaron R. [1 ]
Christensen, Angi M. [1 ]
Marvin, Susan M. [1 ]
机构
[1] Fed Bur Invest Lab, 2501 Invest Pkwy, Quantico, VA 22135 USA
来源
关键词
forensic science; forensic anthropology; elemental analysis; X-ray fluorescence spectrometry; calcium; phosphorus; ELEMENTAL ANALYSIS;
D O I
10.1111/1556-4029.12951
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Elemental analysis of calcium (Ca) and phosphorus (P) has been shown to be useful in differentiating skeletal and nonskeletal material. X-ray fluorescence spectrometry (XRF) is an attractive, nondestructive technique for forensic anthropologists, and the development of portable XRF instrumentation is promising for field applications. This study examines the performance of handheld XRF instrumentation operated in air compared to a traditional benchtop XRF device that has the ability to control the analysis atmosphere. Both instruments can be used to effectively distinguish skeletal from nonskeletal remains. However, as the measurement atmosphere affects detection levels for calcium and phosphorus, Ca/P ratios obtained from the instruments and analysis conditions were found to differ significantly, with analyses conducted in air showing significantly lower phosphorus detection. Consequently, comparison of Ca/P ratios to conclude skeletal versus nonskeletal origin must be based on data collected under similar analysis conditions.
引用
收藏
页码:S190 / S192
页数:3
相关论文
共 50 条
  • [21] Rapid Determination of Trace Metals in Oil Using Handheld X-Ray Fluorescence Spectroscopy
    Chu, Gabriel
    Guinea, David
    Palmer, Peter T.
    SPECTROSCOPY, 2014, 29 (07) : 38 - +
  • [22] DETERMINATION BY X-RAY FLUORESCENCE OF CALCIUM IN CELLULOSE
    ANTWUORI.O
    VISAPAA, A
    PAPER JA PUU-PAPPER OCH TRA, 1969, 51 (12): : 883 - &
  • [23] Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks
    Margui, E.
    Hidalgo, M.
    Queralt, I.
    Van Meel, K.
    Fontas, C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 67 : 17 - 23
  • [24] THIN WINDOWS FOR FLOW PROPORTIONAL COUNTERS IN X-RAY FLUORESCENCE SPECTROMETERS
    BROWN, G
    KANARISS.R
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (06): : 551 - &
  • [25] A tunable focusing monochromator for total reflection x-ray fluorescence spectrometers
    Knoth, J
    Beaven, PA
    Michaelsen, C
    Schneider, H
    Schwenke, H
    X-RAY SPECTROMETRY, 1999, 28 (02) : 110 - 114
  • [26] X-RAY SPECTROMETERS FOR PIXE
    CAMPBELL, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 115 - 125
  • [27] SEMICONDUCTOR X-RAY SPECTROMETERS
    CAMERON, JF
    RIDLEY, JD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (01) : 363 - &
  • [28] A Tunable Focusing Monochromator for Total Reflection X-Ray Fluorescence Spectrometers
    Knoth, J.
    Beaven, P.A.
    Michaelsen, C.
    Schneider, H.
    Schwenke, H.
    X-Ray Spectrometry, 28 (02): : 110 - 114
  • [29] Precision x-ray spectrometers
    Hudson, JC
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA AND REVIEW OF SCIENTIFIC INSTRUMENTS, 1924, 9 (03): : 259 - 301
  • [30] Determination of Soil Calcium Using Field Portable X-Ray Fluorescence
    Zhu, Yuanda
    Weindorf, David C.
    SOIL SCIENCE, 2009, 174 (03) : 151 - 155