Detection of Nosema bombycis by FTA Cards and Loop-Mediated Isothermal Amplification (LAMP)

被引:31
|
作者
Yan, Wei [1 ]
Shen, Zhongyuan [1 ,2 ,3 ]
Tang, Xudong [1 ,2 ]
Xu, Li [1 ,2 ]
Li, Qianlong [1 ,2 ]
Yue, Yajie [1 ,2 ]
Xiao, Shengyan [1 ,2 ]
Fu, Xuliang [1 ]
机构
[1] Jiangsu Univ Sci & Technol, Zhenjiang 212018, Jiangsu, Peoples R China
[2] Chinese Acad Agr Sci, Sericultural Res Inst, Zhenjiang 212018, Jiangsu, Peoples R China
[3] Minist Agr, Key Lab Genet Improvement Silkworm & Mulberry, Zhenjiang 212018, Jiangsu, Peoples R China
关键词
ENCEPHALITOZOON-INTESTINALIS; STOOL SPECIMENS; RAPID DETECTION; PCR DETECTION; MICROSPORIDIA; ENTEROCYTOZOON; IDENTIFICATION; CRYPTOSPORIDIUM; EXTRACTION; CYCLOSPORA;
D O I
10.1007/s00284-014-0619-3
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We successfully established a detection method which exhibited a markedly higher sensitivity than previously developed detection methods for Nosema bombycis by combining glass beads, FTA card, and LAMP. Spores of N. bombycis were first broken by acid-washed glass beads; the DNA was subsequently extracted and purified with the FTA card, and LAMP was performed using primers (LSU296) designed based on the sequence of the LSU rRNA of N. bombycis. The minimum detection concentration was 10 spores/mL. When this method was used to detect pebrine disease in silkworm egg, the detection rate for 500 silkworm eggs, in which only one egg was infected with N. bombycis, was 100 % under our optimized conditions. If the number of eggs in the sample increased to 800 or 1,000, the sample was divided into two equal portions, and the eggs were smashed with glass beads after the addition of 1 mL of TE buffer. The liquid in two tubes was later mixed and applied to the FTA card, and the detection rates were 100 %. Furthermore, the LAMP method established in our study could detect N. bombycis infection in silkworm 24 h earlier than microscopy.
引用
收藏
页码:532 / 540
页数:9
相关论文
共 50 条
  • [41] Tracing Phosphate Ions Generated during Loop-Mediated Isothermal Amplification for Electrochemical Detection of Nosema bombycis Genomic DNA PTP1
    Xie, Shunbi
    Yuan, Yali
    Chai, Yaqin
    Yuan, Ruo
    ANALYTICAL CHEMISTRY, 2015, 87 (20) : 10268 - 10274
  • [42] MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND
    Ocker, Ronja
    Prompunjai, Yongyut
    Chutipongvivate, Salakchit
    Karanis, Panagiotis
    REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO, 2016, 58
  • [43] Loop-Mediated Isothermal Amplification (LAMP): The Better Sibling of PCR?
    Soroka, Marianna
    Wasowicz, Barbara
    Rymaszewska, Anna
    CELLS, 2021, 10 (08)
  • [44] Evaluation of molecular inhibitors of loop-mediated isothermal amplification (LAMP)
    Nwe, May Khat
    Jangpromma, Nisachon
    Taemaitree, Lapatrada
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [45] Development of A Loop-Mediated Isothermal Amplification (LAMP) Assay for Detection of Relapsing Fever Borreliae
    Houmansadr, Faezeh
    Soleimani, Mohammad
    Naddaf, Saied Reza
    JOURNAL OF ARTHROPOD-BORNE DISEASES, 2020, 14 (01) : 47 - 55
  • [46] One-step ultrasensitive detection of microRNAs with loop-mediated isothermal amplification (LAMP)
    Li, Cuiping
    Li, Zhengping
    Jia, Hongxia
    Yan, Jingli
    CHEMICAL COMMUNICATIONS, 2011, 47 (09) : 2595 - 2597
  • [47] The Rapid Detection of Salmonella from Food Samples By Loop-Mediated Isothermal Amplification (LAMP)
    Ueda, Shigeko
    Kuwabara, Yoshihiro
    BIOCONTROL SCIENCE, 2009, 14 (02) : 73 - 76
  • [48] Application of loop-mediated isothermal amplification (LAMP) assays for the detection of bovine herpesvirus 1
    Socha, W.
    Rola, J.
    Urban-Chmiel, R.
    Imudzinski, J. F.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2017, 20 (03): : 619 - 622
  • [49] Loop-Mediated Isothermal Amplification (LAMP) Method for Rapid Detection of Trypanosoma brucei rhodesiense
    Njiru, Zablon Kithinji
    Mikosza, Andrew Stanislaw John
    Armstrong, Tanya
    Enyaru, John Charles
    Ndung'u, Joseph Mathu
    Thompson, Andrew Richard Christopher
    PLOS NEGLECTED TROPICAL DISEASES, 2008, 2 (02):
  • [50] A simple method for the detection of measles virus genome by loop-mediated isothermal amplification (LAMP)
    Fujino, M
    Yoshida, N
    Yamaguchi, S
    Hosaka, N
    Ota, Y
    Notomi, T
    Nakayama, T
    JOURNAL OF MEDICAL VIROLOGY, 2005, 76 (03) : 406 - 413