Evaluation of a photon-counting breast tomosynthesis imaging system

被引:17
|
作者
Maidment, Andrew D. A. [1 ]
Ullberg, Christer [1 ]
Lindman, Karin [1 ]
Adelow, Leif [1 ]
Egerstrom, Johan [1 ]
Eklund, Mathias [1 ]
Francke, Tom [1 ]
Jordung, Ulf [1 ]
Kristoffersson, Tomas [1 ]
Lindqvist, Lars [1 ]
Marchal, Daniel [1 ]
Olla, Hans [1 ]
Penton, Erik [1 ]
Rantanen, Juha [1 ]
Solokov, Skiff [1 ]
Weber, Niclas [1 ]
Westerberg, Hans [1 ]
机构
[1] Univ Penn, Philadelphia, PA 19104 USA
关键词
digital breast tomosynthesis; synthetic tomography; digital mammography; modulation transfer function (MTF); noise power spectra (NPS); clinical trial;
D O I
10.1117/12.654651
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Digital breast tomosynthesis promises solutions to many of the problems associated with projection mammography, including elimination of artifactual densities due to the superposition of normal tissues and increasing the conspicuity of true lesions that would otherwise be masked by superimposed normal tissue. We have investigated tomosynthesis using a digital camera containing 48 photon counting, orientation sensitive, linear detectors which are precisely aligned with the focal spot of the x-ray source. The x-ray source and the digital detectors are scanned in a continuous motion across the object (patient), each linear detector collecting an image at a distinct angle. A preliminary assessment of tomosynthesis image quality has been performed with both qualitative and quantitative methods. Measured values of MTF and NPS appear concordant with theoretical values. The MTF in the scanning direction is dominated by scanning unsharpness and geometric factors, while the NPS is white. The MTF and NPS in the strip direction are somewhat lower than in the scan direction. The NPS of tomographic images show a slight decrease with increasing spatial frequency, related to the sampling and interpolation in the reconstruction process. A phase I clinical trial is ongoing; 9 women have been recruited. Breast positioning is comparable to other imaging systems. The visualization of breast anatomy appears to be superior to screen-film mammography, at the same average glandular dose. Examination of images reconstructed with a sub-sampled set of projection images appears to support the hypothesis that image quality is superior when more projection images are used in the reconstruction.
引用
收藏
页码:B1420 / B1420
页数:11
相关论文
共 50 条
  • [1] Evaluation of a photon-counting breast tomosynthesis imaging system
    Maidment, A
    Albert, M
    Thunberg, S
    Adelöw, L
    Blom, O
    Egerström, J
    Eklund, M
    Francke, T
    Jordung, U
    Kristoffersson, T
    Lindman, K
    Lindqvist, L
    Marchal, D
    Olla, H
    Penton, E
    Rantanen, J
    Solokov, S
    Ullberg, C
    Weber, N
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 572 - 582
  • [2] Evaluation of photon-counting spectral breast tomosynthesis
    Dahlman, Nils
    Fredenberg, Erik
    Aslund, Magnus
    Lundqvist, Mats
    Diekmann, Felix
    Danielsson, Mats
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [3] Clinical evaluation of a photon-counting tomosynthesis mammography system
    Maidment, Andrew D. A.
    Ullberg, Christer
    Francke, Tom
    Lindqvist, Lars
    Sokolov, Skiff
    Lindman, Karin
    Adelow, Leif
    Sunden, Per
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2006, 4046 : 144 - 151
  • [4] Characterization of photon-counting multislit breast tomosynthesis
    Berggren, Karl
    Cederstrom, Bjorn
    Lundqvist, Mats
    Fredenberg, Erik
    MEDICAL PHYSICS, 2018, 45 (02) : 549 - 560
  • [5] Physical characterization of photon-counting tomosynthesis
    Berggren, Karl
    Lundqvist, Mats
    Cederstrom, Bjorn
    Danielsson, Mats
    Fredenberg, Erik
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [6] Evaluation of a photon-counting X-ray imaging system
    Lundqvist, M
    Cederström, B
    Chmill, V
    Danielsson, M
    Hasegawa, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1530 - 1536
  • [7] Lession characterization in spectral photon-counting tomosynthesis
    Cederstrom, Bjorn
    Fredenberg, Erik
    Berggren, Karl
    Erhard, Klaus
    Danielsson, Mats
    Wallis, Matthew
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [8] High speed imaging photon-counting system
    Ryan, O.
    Redfern, M.
    Shearier, A.
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY II, 2006, 6276
  • [10] Low dose and high image quality tomosynthesis with a photon-counting imaging technology
    Francke, T
    Maidment, A
    Thunberg, S
    Adelow, L
    Blom, O
    Egerstrom, J
    Eklund, M
    Jordung, U
    Kristoffersson, T
    Lidman, K
    Lindqvist, L
    Marchal, D
    Olla, H
    Penton, E
    Ratanen, J
    Sokolov, S
    Ullberg, C
    Weber, N
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 42 - 42