Surface characteristics of a porous-surfaced Ti-6Al-4V implant fabricated by electro-discharge-compaction

被引:15
|
作者
Lee, WH
Park, JW
Puleo, DA
Kim, JY [1 ]
机构
[1] Hanyang Univ, Dept Met Engn, Seoul 133791, South Korea
[2] Univ Kentucky, Ctr Biomed Engn, Lexington, KY 40506 USA
[3] Uniduk Univ, Dept Semicond Engn, Kyongju 780713, South Korea
关键词
D O I
10.1023/A:1004768125476
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Electro-discharge-compaction (EDC) is a unique method for producing porous-surfaced metallic implants. The objective of the present studies was to examine the surface characteristics of the Ti-6Al-4V implants formed by EDC. Porous-surfaced Ti-6Al-4V implants were produced by employing EDC using 480 mu F capacitance and 1.5 kJ input energy. X-ray photoelectron spectroscopy was used to study the surface characteristics of the implant materials. C, O, and Ti were the main constituents, with smaller amounts of Al and V. EDC Ti-6Al-4V also contained N. Titanium was present mainly in the forms of mixed oxides and small amounts of nitride and carbide were observed. Al was present in the form of aluminum oxide, while V in the implant surface did not contribute to the formation of the surface oxide film. The surface of conventionally prepared Ti-6Al-4V primarily consists of TiO2, whereas, the surface of the EDC-fabricated Ti-6Al-4V consists of complex Ti and Al oxides as well as small amounts of titanium carbide and nitride components. However, preliminary studies indicated that the implant was biocompatible and supports rapid osseointegration. (C) 2000 Kluwer Academic Publishers.
引用
收藏
页码:593 / 598
页数:6
相关论文
共 50 条
  • [21] Preparation and surface modification of 3D printed Ti-6Al-4V porous implant
    Chun-Yong Liang
    Xiao-Jing Jiang
    Rui-Long Ji
    Bao-E Li
    Xian-Rui Zou
    Hong-Shui Wang
    Jing-Zu Hao
    Tai Yang
    RareMetals, 2021, 40 (05) : 1164 - 1172
  • [22] A comparative study on micro-electro-discharge-machined surface characteristics of Ni-Ti and Ti-6Al-4V with respect to biocompatibility
    Jahan, Muhammad P.
    Kakavand, Pegah
    Alavi, Farshid
    45TH SME NORTH AMERICAN MANUFACTURING RESEARCH CONFERENCE (NAMRC 45), 2017, 10 : 232 - 242
  • [23] Surface Characteristics of Porous Ti-6A1-4V Implants Fabricated by Electro-Discharge-Sintering in a Low Vacuum Atmosphere
    Hyun, C. Y.
    Huh, J. K.
    Lee, W. H.
    KOREAN JOURNAL OF MATERIALS RESEARCH, 2006, 16 (03): : 178 - 182
  • [24] Self-assembled microporous Ti-6Al-4V implant compacts induced by electro-discharge-sintering
    Kim, Y. H.
    Cho, Y. J.
    Lee, C. M.
    Kim, S. J.
    Lee, N. S.
    Kim, K. B.
    Jeon, E. C.
    Sok, J. -H.
    Park, J. S.
    Kwon, H.
    Leee, K. B.
    Lee, W. H.
    SCRIPTA MATERIALIA, 2007, 56 (06) : 449 - 451
  • [25] Diffusion Bonding of Ti-6Al-4V Sheet with Ti-6Al-4V Foam for Biomedical Implant Applications
    Brittany Hamilton
    Scott Oppenheimer
    David C. Dunand
    Daniel Lewis
    Metallurgical and Materials Transactions B, 2013, 44 : 1554 - 1559
  • [26] Diffusion Bonding of Ti-6Al-4V Sheet with Ti-6Al-4V Foam for Biomedical Implant Applications
    Hamilton, Brittany
    Oppenheimer, Scott
    Dunand, David C.
    Lewis, Daniel
    METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 2013, 44 (06): : 1554 - 1559
  • [27] Fracture characteristics of fatigued Ti-6Al-4V ELI as an implant material
    Akahori, T
    Niinomi, M
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1998, 243 (1-2): : 237 - 243
  • [28] Fracture characteristics of fatigued Ti-6Al-4V ELI as an implant material
    Akahori, Toshikazu
    Niinomi, Mitsuo
    Materials Science and Engineering A, 1998, A243 (1-2): : 237 - 243
  • [29] Surface oxidation of Ti-6Al-4V for bio-implant application
    Biswas, A.
    Bhattacharjee, U.
    Manna, I.
    Majumdar, J. Dutta
    SURFACE REVIEW AND LETTERS, 2007, 14 (04) : 597 - 600
  • [30] Porous Ti-6Al-4V Fabricated by Powder Sintering and its Property Evaluation
    Hu, Rui-Hua
    Yan, Cun-Fu
    Lim, Jae-kyoo
    ADVANCES IN CHEMICAL ENGINEERING, PTS 1-3, 2012, 396-398 : 257 - +