Custom-Made Titanium 3-Dimensional Printed Interbody Cages for Treatment of Osteoporotic Fracture-Related Spinal Deformity

被引:43
|
作者
Siu, Timothy L. [1 ]
Rogers, Jeffrey M. [1 ]
Lin, Kainu [1 ]
Thompson, Robert [2 ]
Owbridge, Mark [2 ]
机构
[1] Macquarie Univ, Dept Clin Med, Fac Med & Hlth Sci, N Ryde, NSW, Australia
[2] Anat Pty Ltd, Melbourne, Vic, Australia
关键词
3D printing; Adult spinal deformity; Lateral lumbar interbody fusion; Minimally invasive surgery; Osteoporotic fractures; Personalized medicine; CERVICAL-SPINE; FUSION; RECONSTRUCTION; EXPERIENCE; IMPLANT;
D O I
10.1016/j.wneu.2017.11.160
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Advances in minimally invasive interbody fusion have greatly enhanced surgeons' capability to correct adult spinal deformity with reduced morbidity. However, the feasibility of such approaches is limited in patients with previous osteoporotic fractures as the resultant vertebral deformity renders the end plate geometry incongruous with conventional interbody implants. Current 3-dimensional (3D) printing technology offers a novel solution by fabricating custom-made implants tailored to individual anatomy. We present the results of a patient with osteoporotic lumbar fractures treated by such technology. CASE DESCRIPTION: A 74-year-old woman, with previous osteoporotic fractures at L2 and L3 resulting in concave deformity of the end plates, presented with intractable radiculopathy secondary to lateral recess and foraminal stenosis (L2-3 and L3-4). A minimally invasive lateral lumbar interbody fusion at L2-3 and L3-4 was considered favorable, but due to the associated vertebral collapse, off-the-shelf implants were not compatible with patient anatomy. In silico simulation based on preoperative computed tomography (CT) imaging was thus conducted to design customized cages to cater for the depressed recipient end plates and vertebral loss. The design was converted to implantable titanium cages through 3D additive manufacturing. At surgery, a tight fit between the implants and the targeted disk space was achieved. Postoperative CT scan confirmed excellent implant-end plate matching and restoration of lost disk space. The patient began to ambulate from postoperative day 1 and at 6-month follow-up resolution of radicular symptoms and CT evidence of interbody fusion were recorded. CONCLUSIONS: 3D-printed custom-made interbody cages can help overcome the difficulties in deformity correction secondary to osteoporotic fractures.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 43 条
  • [41] Biomimetic 3D-printed custom-made prosthesis for anterior column reconstruction in the thoracolumbar spine: a tailored option following en bloc resection for spinal tumorsPreliminary results on a case-series of 13 patients
    Marco Girolami
    Stefano Boriani
    Stefano Bandiera
    Giovanni Barbanti-Bródano
    Riccardo Ghermandi
    Silvia Terzi
    Giuseppe Tedesco
    Gisberto Evangelisti
    Valerio Pipola
    Alessandro Gasbarrini
    European Spine Journal, 2018, 27 : 3073 - 3083
  • [42] Biomimetic 3D-printed custom-made prosthesis for anterior column reconstruction in the thoracolumbar spine: a tailored option following en bloc resection for spinal tumors: Preliminary results on a case-series of 13 patients
    Girolami, Marco
    Boriani, Stefano
    Bandiera, Stefano
    Barbanti-Brodano, Giovanni
    Ghermandi, Riccardo
    Terzi, Silvia
    Tedesco, Giuseppe
    Evangelisti, Gisberto
    Pipola, Valerio
    Gasbarrini, Alessandro
    EUROPEAN SPINE JOURNAL, 2018, 27 (12) : 3073 - 3083
  • [43] Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs
    Mie, Keiichiro
    Ishimoto, Takuya
    Okamoto, Mari
    Iimori, Yasumasa
    Ashida, Kazuna
    Yoshizaki, Karin
    Nishida, Hidetaka
    Nakano, Takayoshi
    Akiyoshi, Hideo
    PLOS ONE, 2020, 15 (09):